نمایش منو

Multi-Triple

 

Criteria

Standard Values

Unit

Conductor cross section

Nominal

0.5

0.75

1

1.5

2.5

mm²

Conductor DC Resistance @ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/Ohm

Test voltage :

for 1 minute

2.0 kV A.C or 3.0 kV D.C

K.V

core to core

core to screen

Operating voltage U(rms)

 

500

V

Nominal cross section area of conductor

Insulation thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

Kg/Km

meter

Conductor : 0.5 mm2 (7x0.3 mm)

1x3x0.5

0.6

0.9

6.6

55

1000

2x3x0.5

0.6

1.0

10.1

98

1000

3x3x0.5

0.6

1.0

10.8

127

1000

4x3x0.5

0.6

1.0

11.8

158

1000

5x3x0.5

0.6

1.1

13.1

195

1000

6x3x0.5

0.6

1.1

14.3

227

1000

7x3x0.5

0.6

1.1

14.3

253

1000

10x3x0.5

0.6

1.2

18.4

359

1000

12x3x0.5

0.6

1.2

19.0

415

1000

16x3x0.5

0.6

1.3

21.3

541

1000

20x3x0.5

0.6

1.4

24.0

670

1000

24x3x0.5

0.6

1.5

26.8

802

500

30x3x0.5

0.6

1.5

28.4

971

500

Conductor : 0.75 mm2 (7x0.37 mm)

1x3x0.75

0.6

0.9

7.1

66

1000

2x3x0.75

0.6

1.0

10.9

120

1000

3x3x0.75

0.6

1.0

11.6

159

1000

4x3x0.75

0.6

1.1

12.9

205

1000

5x3x0.75

0.6

1.1

14.1

246

1000

6x3x0.75

0.6

1.1

15.4

288

1000

7x3x0.75

0.6

1.1

15.4

324

1000

10x3x0.75

0.6

1.3

20.2

468

1000

12x3x0.75

0.6

1.3

20.8

543

1000

16x3x0.75

0.6

1.4

23.4

708

1000

20x3x0.75

0.6

1.5

26.3

878

500

24x3x0.75

0.6

1.6

29.4

1050

500

30x3x0.75

0.6

1.6

31.2

1277

500

Nominal cross section area of conductor

Insulation thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)

1x3x1

0.6

0.9

7.5

76

1000

2x3x1

0.6

1.0

11.6

141

1000

3x3x1

0.6

1.0

12.3

189

1000

4x3x1

0.6

1.1

13.7

244

1000

5x3x1

0.6

1.1

15.0

295

1000

6x3x1

0.6

1.2

16.6

353

1000

7x3x1

0.6

1.2

16.6

398

1000

10x3x1

0.6

1.3

21.5

564

1000

12x3x1

0.6

1.3

22.2

658

1000

16x3x1

0.6

1.4

25.0

861

500

20x3x1

0.6

1.5

28.1

1068

500

24x3x1

0.6

1.6

31.4

1279

500

30x3x1

0.6

1.7

33.5

1574

500

Conductor : 1.5 mm2 (7x0.53 mm)

1x3x1.5

0.6

0.9

8.1

97

1000

2x3x1.5

0.6

1.1

12.9

187

1000

3x3x1.5

0.6

1.1

13.7

254

1000

4x3x1.5

0.6

1.1

15.1

323

1000

5x3x1.5

0.6

1.2

16.8

399

1000

6x3x1.5

0.6

1.2

18.3

470

1000

7x3x1.5

0.6

1.2

18.3

532

1000

10x3x1.5

0.6

1.4

23.9

766

1000

12x3x1.5

0.6

1.4

24.8

896

500

16x3x1.5

0.6

1.5

27.8

1174

500

20x3x1.5

0.6

1.6

31.3

1458

500

24x3x1.5

0.6

1.7

35.0

1746

500

30x3x1.5

0.6

1.8

37.3

2152

500

Nominal cross section area of conductor

Insulation thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

Kg/Km

meter

Conductor : 2.5 mm2 (7x0.67 mm)

1x3x2.5

0.7

1.0

9.7

141

1000

2x3x2.5

0.7

1.1

15.2

269

1000

3x3x2.5

0.7

1.2

16.4

378

1000

4x3x2.5

0.7

1.2

18.1

484

1000

5x3x2.5

0.7

1.3

20.1

599

1000

6x3x2.5

0.7

1.4

22.2

716

1000

7x3x2.5

0.7

1.4

22.2

813

1000

10x3x2.5

0.7

1.6

29.0

1167

500

12x3x2.5

0.7

1.6

30.0

1369

500

16x3x2.5

0.7

1.7

33.6

1795

500

20x3x2.5

0.7

1.9

38.0

2244

500

24x3x2.5

0.7

2.0

42.5

2685

500

30x3x2.5

0.7

2.1

45.3

3310

500