نمایش منو

TiMF

 

Criteria

Standard Values

Unit

Conductor cross section

Nominal

0.5

0.75

1

1.5

2.5

mm²

Conductor DC Resistance @ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/Ohm

Test voltage :

for 1 minute

2.0 kV A.C or 3.0 kV D.C

K.V

core to core

core to screen

Operating voltage U(rms)

 

500

V

Nominal cross section area of conductor

Insulation thickness

Lead Sheath Thickness

Diameter Over Lead Sheath

Armour Wire Diameter

Diameter Under Armour

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

mm

Kg/Km

meter

Conductor : 0.5 mm2 (7x0.30 mm)

1x3x0.5

0.6

0.9

9.0

0.9

9.2

1.4

13.8

581

1000

2x3x0.5

0.6

1.0

13.5

0.9

13.5

1.5

18.3

905

1000

3x3x0.5

0.6

1.0

14.2

0.9

14.2

1.5

19.0

987

1000

4x3x0.5

0.6

1.0

15.4

0.9

15.4

1.5

20.2

1088

1000

5x3x0.5

0.6

1.1

16.9

0.9

16.7

1.6

21.7

1263

1000

6x3x0.5

0.6

1.1

18.3

1.25

18.1

1.6

23.8

1527

1000

7x3x0.5

0.6

1.1

18.3

1.25

18.1

1.6

23.8

1562

1000

10x3x0.5

0.6

1.2

23.1

1.25

22.7

1.7

28.6

2055

1000

12x3x0.5

0.6

1.2

23.8

1.25

23.4

1.7

29.3

2181

500

16x3x0.5

0.6

1.3

26.5

1.25

25.9

1.8

32.0

2592

500

20x3x0.5

0.6

1.4

29.6

1.25

28.8

1.8

34.9

3039

500

24x3x0.5

0.6

1.4

32.7

1.6

31.9

1.9

38.9

3677

500

30x3x0.5

0.6

1.5

34.8

1.6

34.2

2.0

41.4

4208

500

Conductor : 0.75 mm2 (7x0.37 mm)

1x3x0.75

0.6

0.9

9.4

0.9

9.6

1.4

14.2

622

1000

2x3x0.75

0.6

1.0

14.3

0.9

14.3

1.5

19.1

982

1000

3x3x0.75

0.6

1.0

15.1

0.9

15.1

1.5

19.9

1077

1000

4x3x0.75

0.6

1.1

16.6

0.9

16.4

1.6

21.4

1257

1000

5x3x0.75

0.6

1.1

18.1

1.25

17.9

1.6

23.6

1528

1000

6x3x0.75

0.6

1.1

19.6

1.25

19.4

1.6

25.1

1682

1000

7x3x0.75

0.6

1.1

19.6

1.25

19.4

1.6

25.1

1727

1000

10x3x0.75

0.6

1.3

25.0

1.25

24.4

1.8

30.5

2374

500

12x3x0.75

0.6

1.3

25.8

1.25

25.2

1.8

31.3

2526

500

16x3x0.75

0.6

1.4

28.7

1.25

27.9

1.8

34.0

3001

500

20x3x0.75

0.6

1.4

31.9

1.6

31.1

1.9

38.1

3672

500

24x3x0.75

0.6

1.5

35.8

1.6

35.2

2.0

42.4

4377

500

30x3x0.75

0.6

1.6

38.1

1.6

37.3

2.1

44.7

4965

500

Nominal cross section area of conductor

Insulation thickness

Lead Sheath Thickness

Diameter Over Lead Sheath

Armour Wire Diameter

Diameter Under Armour

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)

1x3x1

0.6

0.9

9.8

0.9

10.0

1.4

14.6

647

1000

2x3x1

0.6

1.0

15.1

0.9

15.1

1.5

19.9

1034

1000

3x3x1

0.6

1.1

16.1

0.9

15.9

1.5

20.7

1188

1000

4x3x1

0.6

1.1

17.5

0.9

17.3

1.6

22.3

1339

1000

5x3x1

0.6

1.1

19.0

1.25

18.8

1.6

24.5

1628

1000

6x3x1

0.6

1.2

20.9

1.25

20.5

1.7

26.4

1867

1000

7x3x1

0.6

1.2

20.9

1.25

20.5

1.7

26.4

1921

1000

10x3x1

0.6

1.3

26.4

1.25

25.8

1.8

31.9

2563

500

12x3x1

0.6

1.3

27.3

1.25

26.7

1.8

32.8

2736

500

16x3x1

0.6

1.4

30.4

1.6

29.6

1.9

36.6

3504

500

20x3x1

0.6

1.5

34.0

1.6

33.4

2.0

40.6

4168

500

24x3x1

0.6

1.6

38.2

1.6

37.4

2.1

44.8

4892

500

30x3x1

0.6

1.6

40.4

2

39.6

2.1

47.8

5749

500

Conductor : 1.5 mm2 (7x0.53 mm)

1x3x1.5

0.6

0.9

10.5

0.9

10.7

1.4

15.3

707

1000

2x3x1.5

0.6

1.1

16.5

0.9

16.3

1.6

21.3

1212

1000

3x3x1.5

0.6

1.1

17.4

1.25

17.2

1.6

22.9

1486

1000

4x3x1.5

0.6

1.1

19.0

1.25

18.8

1.6

24.5

1660

1000

5x3x1.5

0.6

1.2

20.9

1.25

20.5

1.7

26.4

1923

1000

6x3x1.5

0.6

1.2

22.7

1.25

22.3

1.7

28.2

2135

1000

7x3x1.5

0.6

1.2

22.7

1.25

22.3

1.7

28.2

2207

1000

10x3x1.5

0.6

1.4

29.1

1.25

28.3

1.8

34.4

3046

500

12x3x1.5

0.6

1.4

30.0

1.25

29.2

1.9

35.5

3278

500

16x3x1.5

0.6

1.5

33.5

1.6

32.9

2.0

40.1

4235

500

20x3x1.5

0.6

1.6

37.9

1.6

37.1

2.1

44.5

5048

500

24x3x1.5

0.6

1.7

42.1

2

41.1

2.2

49.5

6226

500

30x3x1.5

0.6

1.7

44.5

2

43.5

2.2

51.9

6903

500

Nominal cross section area of conductor

Insulation thickness

Lead Sheath Thickness

Diameter Over Lead Sheath

Armour Wire Diameter

Diameter Under Armour

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

mm

Kg/Km

meter

Conductor : 2.5 mm2 (7x0.67 mm)

1x3x2.5

0.7

1.0

12.0

0.9

12.0

1.5

16.8

868

1000

2x3x2.5

0.7

1.1

19.0

1.25

18.8

1.6

24.5

1602

1000

3x3x2.5

0.7

1.2

20.4

1.25

20.0

1.7

25.9

1868

1000

4x3x2.5

0.7

1.2

22.2

1.25

21.8

1.7

27.7

2121

1000

5x3x2.5

0.7

1.3

24.5

1.25

23.9

1.8

30.0

2459

500

6x3x2.5

0.7

1.3

26.7

1.25

26.1

1.8

32.2

2734

500

7x3x2.5

0.7

1.3

26.7

1.25

26.1

1.8

32.2

2842

500

10x3x2.5

0.7

1.5

34.3

1.6

33.7

2.0

40.9

4265

500

12x3x2.5

0.7

1.5

35.9

1.6

35.3

2.0

42.5

4654

500

16x3x2.5

0.7

1.6

40.0

2

39.2

2.2

47.6

5948

500

20x3x2.5

0.7

1.8

45.0

2

44.2

2.3

52.8

7196

500

24x3x2.5

0.7

1.9

50.4

2.5

49.4

2.4

59.2

8943

500

30x3x2.5

0.7

2.0

53.6

2.5

52.4

2.5

62.4

10168

500