TiMF
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
36.7 |
25.0 |
18.5 |
12.3 |
7.4 |
Ohm/kM |
Insulation resistance |
min. |
100 |
MOhm x km |
||||
Mutual capacitance |
max. |
250 |
nF/km |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 1 minute |
2.0 kV A.C or 3.0 kV D.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
500 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Lead Sheath Thickness |
Diameter Over Lead Sheath |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.30 mm) |
|||||||||
1x3x0.5 |
0.6 |
0.9 |
9.0 |
0.9 |
9.2 |
1.4 |
13.8 |
581 |
1000 |
2x3x0.5 |
0.6 |
1.0 |
13.5 |
0.9 |
13.5 |
1.5 |
18.3 |
905 |
1000 |
3x3x0.5 |
0.6 |
1.0 |
14.2 |
0.9 |
14.2 |
1.5 |
19.0 |
987 |
1000 |
4x3x0.5 |
0.6 |
1.0 |
15.4 |
0.9 |
15.4 |
1.5 |
20.2 |
1088 |
1000 |
5x3x0.5 |
0.6 |
1.1 |
16.9 |
0.9 |
16.7 |
1.6 |
21.7 |
1263 |
1000 |
6x3x0.5 |
0.6 |
1.1 |
18.3 |
1.25 |
18.1 |
1.6 |
23.8 |
1527 |
1000 |
7x3x0.5 |
0.6 |
1.1 |
18.3 |
1.25 |
18.1 |
1.6 |
23.8 |
1562 |
1000 |
10x3x0.5 |
0.6 |
1.2 |
23.1 |
1.25 |
22.7 |
1.7 |
28.6 |
2055 |
1000 |
12x3x0.5 |
0.6 |
1.2 |
23.8 |
1.25 |
23.4 |
1.7 |
29.3 |
2181 |
500 |
16x3x0.5 |
0.6 |
1.3 |
26.5 |
1.25 |
25.9 |
1.8 |
32.0 |
2592 |
500 |
20x3x0.5 |
0.6 |
1.4 |
29.6 |
1.25 |
28.8 |
1.8 |
34.9 |
3039 |
500 |
24x3x0.5 |
0.6 |
1.4 |
32.7 |
1.6 |
31.9 |
1.9 |
38.9 |
3677 |
500 |
30x3x0.5 |
0.6 |
1.5 |
34.8 |
1.6 |
34.2 |
2.0 |
41.4 |
4208 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||||||
1x3x0.75 |
0.6 |
0.9 |
9.4 |
0.9 |
9.6 |
1.4 |
14.2 |
622 |
1000 |
2x3x0.75 |
0.6 |
1.0 |
14.3 |
0.9 |
14.3 |
1.5 |
19.1 |
982 |
1000 |
3x3x0.75 |
0.6 |
1.0 |
15.1 |
0.9 |
15.1 |
1.5 |
19.9 |
1077 |
1000 |
4x3x0.75 |
0.6 |
1.1 |
16.6 |
0.9 |
16.4 |
1.6 |
21.4 |
1257 |
1000 |
5x3x0.75 |
0.6 |
1.1 |
18.1 |
1.25 |
17.9 |
1.6 |
23.6 |
1528 |
1000 |
6x3x0.75 |
0.6 |
1.1 |
19.6 |
1.25 |
19.4 |
1.6 |
25.1 |
1682 |
1000 |
7x3x0.75 |
0.6 |
1.1 |
19.6 |
1.25 |
19.4 |
1.6 |
25.1 |
1727 |
1000 |
10x3x0.75 |
0.6 |
1.3 |
25.0 |
1.25 |
24.4 |
1.8 |
30.5 |
2374 |
500 |
12x3x0.75 |
0.6 |
1.3 |
25.8 |
1.25 |
25.2 |
1.8 |
31.3 |
2526 |
500 |
16x3x0.75 |
0.6 |
1.4 |
28.7 |
1.25 |
27.9 |
1.8 |
34.0 |
3001 |
500 |
20x3x0.75 |
0.6 |
1.4 |
31.9 |
1.6 |
31.1 |
1.9 |
38.1 |
3672 |
500 |
24x3x0.75 |
0.6 |
1.5 |
35.8 |
1.6 |
35.2 |
2.0 |
42.4 |
4377 |
500 |
30x3x0.75 |
0.6 |
1.6 |
38.1 |
1.6 |
37.3 |
2.1 |
44.7 |
4965 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Lead Sheath Thickness |
Diameter Over Lead Sheath |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||||||
1x3x1 |
0.6 |
0.9 |
9.8 |
0.9 |
10.0 |
1.4 |
14.6 |
647 |
1000 |
2x3x1 |
0.6 |
1.0 |
15.1 |
0.9 |
15.1 |
1.5 |
19.9 |
1034 |
1000 |
3x3x1 |
0.6 |
1.1 |
16.1 |
0.9 |
15.9 |
1.5 |
20.7 |
1188 |
1000 |
4x3x1 |
0.6 |
1.1 |
17.5 |
0.9 |
17.3 |
1.6 |
22.3 |
1339 |
1000 |
5x3x1 |
0.6 |
1.1 |
19.0 |
1.25 |
18.8 |
1.6 |
24.5 |
1628 |
1000 |
6x3x1 |
0.6 |
1.2 |
20.9 |
1.25 |
20.5 |
1.7 |
26.4 |
1867 |
1000 |
7x3x1 |
0.6 |
1.2 |
20.9 |
1.25 |
20.5 |
1.7 |
26.4 |
1921 |
1000 |
10x3x1 |
0.6 |
1.3 |
26.4 |
1.25 |
25.8 |
1.8 |
31.9 |
2563 |
500 |
12x3x1 |
0.6 |
1.3 |
27.3 |
1.25 |
26.7 |
1.8 |
32.8 |
2736 |
500 |
16x3x1 |
0.6 |
1.4 |
30.4 |
1.6 |
29.6 |
1.9 |
36.6 |
3504 |
500 |
20x3x1 |
0.6 |
1.5 |
34.0 |
1.6 |
33.4 |
2.0 |
40.6 |
4168 |
500 |
24x3x1 |
0.6 |
1.6 |
38.2 |
1.6 |
37.4 |
2.1 |
44.8 |
4892 |
500 |
30x3x1 |
0.6 |
1.6 |
40.4 |
2 |
39.6 |
2.1 |
47.8 |
5749 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||||||
1x3x1.5 |
0.6 |
0.9 |
10.5 |
0.9 |
10.7 |
1.4 |
15.3 |
707 |
1000 |
2x3x1.5 |
0.6 |
1.1 |
16.5 |
0.9 |
16.3 |
1.6 |
21.3 |
1212 |
1000 |
3x3x1.5 |
0.6 |
1.1 |
17.4 |
1.25 |
17.2 |
1.6 |
22.9 |
1486 |
1000 |
4x3x1.5 |
0.6 |
1.1 |
19.0 |
1.25 |
18.8 |
1.6 |
24.5 |
1660 |
1000 |
5x3x1.5 |
0.6 |
1.2 |
20.9 |
1.25 |
20.5 |
1.7 |
26.4 |
1923 |
1000 |
6x3x1.5 |
0.6 |
1.2 |
22.7 |
1.25 |
22.3 |
1.7 |
28.2 |
2135 |
1000 |
7x3x1.5 |
0.6 |
1.2 |
22.7 |
1.25 |
22.3 |
1.7 |
28.2 |
2207 |
1000 |
10x3x1.5 |
0.6 |
1.4 |
29.1 |
1.25 |
28.3 |
1.8 |
34.4 |
3046 |
500 |
12x3x1.5 |
0.6 |
1.4 |
30.0 |
1.25 |
29.2 |
1.9 |
35.5 |
3278 |
500 |
16x3x1.5 |
0.6 |
1.5 |
33.5 |
1.6 |
32.9 |
2.0 |
40.1 |
4235 |
500 |
20x3x1.5 |
0.6 |
1.6 |
37.9 |
1.6 |
37.1 |
2.1 |
44.5 |
5048 |
500 |
24x3x1.5 |
0.6 |
1.7 |
42.1 |
2 |
41.1 |
2.2 |
49.5 |
6226 |
500 |
30x3x1.5 |
0.6 |
1.7 |
44.5 |
2 |
43.5 |
2.2 |
51.9 |
6903 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Lead Sheath Thickness |
Diameter Over Lead Sheath |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||||||
1x3x2.5 |
0.7 |
1.0 |
12.0 |
0.9 |
12.0 |
1.5 |
16.8 |
868 |
1000 |
2x3x2.5 |
0.7 |
1.1 |
19.0 |
1.25 |
18.8 |
1.6 |
24.5 |
1602 |
1000 |
3x3x2.5 |
0.7 |
1.2 |
20.4 |
1.25 |
20.0 |
1.7 |
25.9 |
1868 |
1000 |
4x3x2.5 |
0.7 |
1.2 |
22.2 |
1.25 |
21.8 |
1.7 |
27.7 |
2121 |
1000 |
5x3x2.5 |
0.7 |
1.3 |
24.5 |
1.25 |
23.9 |
1.8 |
30.0 |
2459 |
500 |
6x3x2.5 |
0.7 |
1.3 |
26.7 |
1.25 |
26.1 |
1.8 |
32.2 |
2734 |
500 |
7x3x2.5 |
0.7 |
1.3 |
26.7 |
1.25 |
26.1 |
1.8 |
32.2 |
2842 |
500 |
10x3x2.5 |
0.7 |
1.5 |
34.3 |
1.6 |
33.7 |
2.0 |
40.9 |
4265 |
500 |
12x3x2.5 |
0.7 |
1.5 |
35.9 |
1.6 |
35.3 |
2.0 |
42.5 |
4654 |
500 |
16x3x2.5 |
0.7 |
1.6 |
40.0 |
2 |
39.2 |
2.2 |
47.6 |
5948 |
500 |
20x3x2.5 |
0.7 |
1.8 |
45.0 |
2 |
44.2 |
2.3 |
52.8 |
7196 |
500 |
24x3x2.5 |
0.7 |
1.9 |
50.4 |
2.5 |
49.4 |
2.4 |
59.2 |
8943 |
500 |
30x3x2.5 |
0.7 |
2.0 |
53.6 |
2.5 |
52.4 |
2.5 |
62.4 |
10168 |
500 |

|