Criteria

Standard Values

Unit

Conductor cross section

Nominal

0.5

0.75

1

1.5

2.5

mm²

Conductor DC Resistance @ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/Ohm

Test voltage :

for 1 minute

2.0 kV A.C or 3.0 kV D.C

K.V

core to core

core to screen

Operating voltage U(rms)

 

500

V

Nominal cross section area of conductor

Insulation thickness

Lead Sheath Thickness

Diameter Over Lead Sheath

Armour Wire Diameter

Diameter Under Armour

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

mm

Kg/Km

meter

Conductor : 0.5 mm2 (7x0.30 mm)

1x3x0.5

0.6

0.9

8.6

0.9

8.8

1.4

13.4

553

1000

2x3x0.5

0.6

1.0

12.1

0.9

12.1

1.5

16.9

810

1000

3x3x0.5

0.6

1.0

12.8

0.9

12.8

1.5

17.6

874

1000

4x3x0.5

0.6

1.0

13.8

0.9

13.8

1.5

18.6

959

1000

5x3x0.5

0.6

1.0

14.9

0.9

14.9

1.5

19.7

1053

1000

6x3x0.5

0.6

1.1

16.3

0.9

16.1

1.5

20.9

1198

1000

7x3x0.5

0.6

1.1

16.3

0.9

16.1

1.5

20.9

1225

1000

10x3x0.5

0.6

1.2

20.4

1.25

20.0

1.6

25.7

1768

1000

12x3x0.5

0.6

1.2

21.0

1.25

20.6

1.7

26.5

1883

1000

16x3x0.5

0.6

1.2

23.1

1.25

22.7

1.7

28.6

2142

1000

20x3x0.5

0.6

1.3

25.8

1.25

25.2

1.8

31.3

2507

500

24x3x0.5

0.6

1.3

28.4

1.25

27.8

1.8

33.9

2819

500

30x3x0.5

0.6

1.4

30.2

1.6

29.4

1.9

36.4

3417

500

Conductor : 0.75 mm2 (7x0.37 mm)

1x3x0.75

0.6

0.9

9.1

0.9

9.3

1.4

13.9

588

1000

2x3x0.75

0.6

1.0

12.9

0.9

12.9

1.5

17.7

877

1000

3x3x0.75

0.6

1.0

13.6

0.9

13.6

1.5

18.4

958

1000

4x3x0.75

0.6

1.0

14.7

0.9

14.7

1.5

19.5

1058

1000

5x3x0.75

0.6

1.1

16.1

0.9

15.9

1.5

20.7

1215

1000

6x3x0.75

0.6

1.1

17.4

1.25

17.2

1.6

22.9

1481

1000

7x3x0.75

0.6

1.1

17.4

1.25

17.2

1.6

22.9

1517

1000

10x3x0.75

0.6

1.2

22.0

1.25

21.6

1.7

27.5

2000

1000

12x3x0.75

0.6

1.2

22.6

1.25

22.2

1.7

28.1

2116

1000

16x3x0.75

0.6

1.3

25.2

1.25

24.6

1.8

30.7

2521

500

20x3x0.75

0.6

1.3

27.9

1.25

27.3

1.8

33.4

2867

500

24x3x0.75

0.6

1.4

31.0

1.6

30.2

1.9

37.2

3574

500

30x3x0.75

0.6

1.5

33.0

1.6

32.4

2.0

39.6

4099

500

Nominal cross section area of conductor

Insulation thickness

Lead Sheath Thickness

Diameter Over Lead Sheath

Armour Wire Diameter

Diameter Under Armour

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)

1x3x1

0.6

0.9

9.5

0.9

9.7

1.4

14.3

619

1000

2x3x1

0.6

1.0

13.6

0.9

13.6

1.5

18.4

932

1000

3x3x1

0.6

1.0

14.3

0.9

14.3

1.5

19.1

1019

1000

4x3x1

0.6

1.0

15.5

0.9

15.5

1.5

20.3

1135

1000

5x3x1

0.6

1.1

17.0

0.9

16.8

1.6

21.8

1315

1000

6x3x1

0.6

1.1

18.4

1.25

18.2

1.6

23.9

1589

1000

7x3x1

0.6

1.1

18.4

1.25

18.2

1.6

23.9

1634

1000

10x3x1

0.6

1.2

23.3

1.25

22.9

1.7

28.8

2169

1000

12x3x1

0.6

1.2

24.0

1.25

23.6

1.7

29.5

2315

500

16x3x1

0.6

1.3

26.8

1.25

26.2

1.8

32.3

2767

500

20x3x1

0.6

1.4

29.9

1.25

29.1

1.8

35.2

3254

500

24x3x1

0.6

1.4

33.0

1.6

32.2

1.9

39.2

3923

500

30x3x1

0.6

1.5

35.1

1.6

34.5

2.0

41.7

4531

500

Conductor : 1.5 mm2 (7x0.53 mm)

1x3x1.5

0.6

0.9

10.1

0.9

10.3

1.4

14.9

677

1000

2x3x1.5

0.6

1.0

14.7

0.9

14.7

1.5

19.5

1041

1000

3x3x1.5

0.6

1.1

15.7

0.9

15.5

1.5

20.3

1203

1000

4x3x1.5

0.6

1.1

17.1

0.9

16.9

1.6

21.9

1357

1000

5x3x1.5

0.6

1.1

18.6

1.25

18.4

1.6

24.1

1654

1000

6x3x1.5

0.6

1.2

20.3

1.25

19.9

1.7

25.8

1900

1000

7x3x1.5

0.6

1.2

20.3

1.25

19.9

1.7

25.8

1963

1000

10x3x1.5

0.6

1.3

25.7

1.25

25.1

1.8

31.2

2618

500

12x3x1.5

0.6

1.3

26.6

1.25

26.0

1.8

32.1

2808

500

16x3x1.5

0.6

1.4

29.6

1.25

28.8

1.9

35.1

3379

500

20x3x1.5

0.6

1.5

33.1

1.6

32.5

2.0

39.7

4292

500

24x3x1.5

0.6

1.6

37.2

1.6

36.4

2.1

43.8

5047

500

30x3x1.5

0.6

1.6

39.3

2

38.5

2.1

46.7

5962

500

Nominal cross section area of conductor

Insulation thickness

Lead Sheath Thickness

Diameter Over Lead Sheath

Armour Wire Diameter

Diameter Under Armour

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

mm

Kg/Km

meter

Conductor : 2.5 mm2 (7x0.67 mm)

1x3x2.5

0.7

1.0

11.7

0.9

11.7

1.4

16.3

829

1000

2x3x2.5

0.7

1.1

17.2

1.25

17.0

1.6

22.7

1457

1000

3x3x2.5

0.7

1.1

18.2

1.25

18.0

1.6

23.7

1633

1000

4x3x2.5

0.7

1.2

20.1

1.25

19.7

1.7

25.6

1911

1000

5x3x2.5

0.7

1.2

21.9

1.25

21.5

1.7

27.4

2149

1000

6x3x2.5

0.7

1.3

24.0

1.25

23.4

1.7

29.3

2456

500

7x3x2.5

0.7

1.3

24.0

1.25

23.4

1.7

29.3

2553

500

10x3x2.5

0.7

1.4

30.6

1.6

29.8

1.9

36.8

3688

500

12x3x2.5

0.7

1.4

31.6

1.6

30.8

1.9

37.8

3975

500

16x3x2.5

0.7

1.5

35.6

1.6

35.0

2.0

42.2

4903

500

20x3x2.5

0.7

1.6

39.8

2

39.0

2.2

47.4

6161

500

24x3x2.5

0.7

1.7

44.3

2

43.3

2.3

51.9

7140

500

30x3x2.5

0.7

1.8

47.1

2

46.3

2.3

54.9

8196

500