Multi-Triple
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
36.7 |
25.0 |
18.5 |
12.3 |
7.4 |
Ohm/kM |
Insulation resistance |
min. |
100 |
MOhm x km |
||||
Mutual capacitance |
max. |
250 |
nF/km |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 1 minute |
2.0 kV A.C or 3.0 kV D.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
500 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Lead Sheath Thickness |
Diameter Over Lead Sheath |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.30 mm) |
|||||||||
1x3x0.5 |
0.6 |
0.9 |
8.6 |
0.9 |
8.8 |
1.4 |
13.4 |
553 |
1000 |
2x3x0.5 |
0.6 |
1.0 |
12.1 |
0.9 |
12.1 |
1.5 |
16.9 |
810 |
1000 |
3x3x0.5 |
0.6 |
1.0 |
12.8 |
0.9 |
12.8 |
1.5 |
17.6 |
874 |
1000 |
4x3x0.5 |
0.6 |
1.0 |
13.8 |
0.9 |
13.8 |
1.5 |
18.6 |
959 |
1000 |
5x3x0.5 |
0.6 |
1.0 |
14.9 |
0.9 |
14.9 |
1.5 |
19.7 |
1053 |
1000 |
6x3x0.5 |
0.6 |
1.1 |
16.3 |
0.9 |
16.1 |
1.5 |
20.9 |
1198 |
1000 |
7x3x0.5 |
0.6 |
1.1 |
16.3 |
0.9 |
16.1 |
1.5 |
20.9 |
1225 |
1000 |
10x3x0.5 |
0.6 |
1.2 |
20.4 |
1.25 |
20.0 |
1.6 |
25.7 |
1768 |
1000 |
12x3x0.5 |
0.6 |
1.2 |
21.0 |
1.25 |
20.6 |
1.7 |
26.5 |
1883 |
1000 |
16x3x0.5 |
0.6 |
1.2 |
23.1 |
1.25 |
22.7 |
1.7 |
28.6 |
2142 |
1000 |
20x3x0.5 |
0.6 |
1.3 |
25.8 |
1.25 |
25.2 |
1.8 |
31.3 |
2507 |
500 |
24x3x0.5 |
0.6 |
1.3 |
28.4 |
1.25 |
27.8 |
1.8 |
33.9 |
2819 |
500 |
30x3x0.5 |
0.6 |
1.4 |
30.2 |
1.6 |
29.4 |
1.9 |
36.4 |
3417 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||||||
1x3x0.75 |
0.6 |
0.9 |
9.1 |
0.9 |
9.3 |
1.4 |
13.9 |
588 |
1000 |
2x3x0.75 |
0.6 |
1.0 |
12.9 |
0.9 |
12.9 |
1.5 |
17.7 |
877 |
1000 |
3x3x0.75 |
0.6 |
1.0 |
13.6 |
0.9 |
13.6 |
1.5 |
18.4 |
958 |
1000 |
4x3x0.75 |
0.6 |
1.0 |
14.7 |
0.9 |
14.7 |
1.5 |
19.5 |
1058 |
1000 |
5x3x0.75 |
0.6 |
1.1 |
16.1 |
0.9 |
15.9 |
1.5 |
20.7 |
1215 |
1000 |
6x3x0.75 |
0.6 |
1.1 |
17.4 |
1.25 |
17.2 |
1.6 |
22.9 |
1481 |
1000 |
7x3x0.75 |
0.6 |
1.1 |
17.4 |
1.25 |
17.2 |
1.6 |
22.9 |
1517 |
1000 |
10x3x0.75 |
0.6 |
1.2 |
22.0 |
1.25 |
21.6 |
1.7 |
27.5 |
2000 |
1000 |
12x3x0.75 |
0.6 |
1.2 |
22.6 |
1.25 |
22.2 |
1.7 |
28.1 |
2116 |
1000 |
16x3x0.75 |
0.6 |
1.3 |
25.2 |
1.25 |
24.6 |
1.8 |
30.7 |
2521 |
500 |
20x3x0.75 |
0.6 |
1.3 |
27.9 |
1.25 |
27.3 |
1.8 |
33.4 |
2867 |
500 |
24x3x0.75 |
0.6 |
1.4 |
31.0 |
1.6 |
30.2 |
1.9 |
37.2 |
3574 |
500 |
30x3x0.75 |
0.6 |
1.5 |
33.0 |
1.6 |
32.4 |
2.0 |
39.6 |
4099 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Lead Sheath Thickness |
Diameter Over Lead Sheath |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||||||
1x3x1 |
0.6 |
0.9 |
9.5 |
0.9 |
9.7 |
1.4 |
14.3 |
619 |
1000 |
2x3x1 |
0.6 |
1.0 |
13.6 |
0.9 |
13.6 |
1.5 |
18.4 |
932 |
1000 |
3x3x1 |
0.6 |
1.0 |
14.3 |
0.9 |
14.3 |
1.5 |
19.1 |
1019 |
1000 |
4x3x1 |
0.6 |
1.0 |
15.5 |
0.9 |
15.5 |
1.5 |
20.3 |
1135 |
1000 |
5x3x1 |
0.6 |
1.1 |
17.0 |
0.9 |
16.8 |
1.6 |
21.8 |
1315 |
1000 |
6x3x1 |
0.6 |
1.1 |
18.4 |
1.25 |
18.2 |
1.6 |
23.9 |
1589 |
1000 |
7x3x1 |
0.6 |
1.1 |
18.4 |
1.25 |
18.2 |
1.6 |
23.9 |
1634 |
1000 |
10x3x1 |
0.6 |
1.2 |
23.3 |
1.25 |
22.9 |
1.7 |
28.8 |
2169 |
1000 |
12x3x1 |
0.6 |
1.2 |
24.0 |
1.25 |
23.6 |
1.7 |
29.5 |
2315 |
500 |
16x3x1 |
0.6 |
1.3 |
26.8 |
1.25 |
26.2 |
1.8 |
32.3 |
2767 |
500 |
20x3x1 |
0.6 |
1.4 |
29.9 |
1.25 |
29.1 |
1.8 |
35.2 |
3254 |
500 |
24x3x1 |
0.6 |
1.4 |
33.0 |
1.6 |
32.2 |
1.9 |
39.2 |
3923 |
500 |
30x3x1 |
0.6 |
1.5 |
35.1 |
1.6 |
34.5 |
2.0 |
41.7 |
4531 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||||||
1x3x1.5 |
0.6 |
0.9 |
10.1 |
0.9 |
10.3 |
1.4 |
14.9 |
677 |
1000 |
2x3x1.5 |
0.6 |
1.0 |
14.7 |
0.9 |
14.7 |
1.5 |
19.5 |
1041 |
1000 |
3x3x1.5 |
0.6 |
1.1 |
15.7 |
0.9 |
15.5 |
1.5 |
20.3 |
1203 |
1000 |
4x3x1.5 |
0.6 |
1.1 |
17.1 |
0.9 |
16.9 |
1.6 |
21.9 |
1357 |
1000 |
5x3x1.5 |
0.6 |
1.1 |
18.6 |
1.25 |
18.4 |
1.6 |
24.1 |
1654 |
1000 |
6x3x1.5 |
0.6 |
1.2 |
20.3 |
1.25 |
19.9 |
1.7 |
25.8 |
1900 |
1000 |
7x3x1.5 |
0.6 |
1.2 |
20.3 |
1.25 |
19.9 |
1.7 |
25.8 |
1963 |
1000 |
10x3x1.5 |
0.6 |
1.3 |
25.7 |
1.25 |
25.1 |
1.8 |
31.2 |
2618 |
500 |
12x3x1.5 |
0.6 |
1.3 |
26.6 |
1.25 |
26.0 |
1.8 |
32.1 |
2808 |
500 |
16x3x1.5 |
0.6 |
1.4 |
29.6 |
1.25 |
28.8 |
1.9 |
35.1 |
3379 |
500 |
20x3x1.5 |
0.6 |
1.5 |
33.1 |
1.6 |
32.5 |
2.0 |
39.7 |
4292 |
500 |
24x3x1.5 |
0.6 |
1.6 |
37.2 |
1.6 |
36.4 |
2.1 |
43.8 |
5047 |
500 |
30x3x1.5 |
0.6 |
1.6 |
39.3 |
2 |
38.5 |
2.1 |
46.7 |
5962 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Lead Sheath Thickness |
Diameter Over Lead Sheath |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||||||
1x3x2.5 |
0.7 |
1.0 |
11.7 |
0.9 |
11.7 |
1.4 |
16.3 |
829 |
1000 |
2x3x2.5 |
0.7 |
1.1 |
17.2 |
1.25 |
17.0 |
1.6 |
22.7 |
1457 |
1000 |
3x3x2.5 |
0.7 |
1.1 |
18.2 |
1.25 |
18.0 |
1.6 |
23.7 |
1633 |
1000 |
4x3x2.5 |
0.7 |
1.2 |
20.1 |
1.25 |
19.7 |
1.7 |
25.6 |
1911 |
1000 |
5x3x2.5 |
0.7 |
1.2 |
21.9 |
1.25 |
21.5 |
1.7 |
27.4 |
2149 |
1000 |
6x3x2.5 |
0.7 |
1.3 |
24.0 |
1.25 |
23.4 |
1.7 |
29.3 |
2456 |
500 |
7x3x2.5 |
0.7 |
1.3 |
24.0 |
1.25 |
23.4 |
1.7 |
29.3 |
2553 |
500 |
10x3x2.5 |
0.7 |
1.4 |
30.6 |
1.6 |
29.8 |
1.9 |
36.8 |
3688 |
500 |
12x3x2.5 |
0.7 |
1.4 |
31.6 |
1.6 |
30.8 |
1.9 |
37.8 |
3975 |
500 |
16x3x2.5 |
0.7 |
1.5 |
35.6 |
1.6 |
35.0 |
2.0 |
42.2 |
4903 |
500 |
20x3x2.5 |
0.7 |
1.6 |
39.8 |
2 |
39.0 |
2.2 |
47.4 |
6161 |
500 |
24x3x2.5 |
0.7 |
1.7 |
44.3 |
2 |
43.3 |
2.3 |
51.9 |
7140 |
500 |
30x3x2.5 |
0.7 |
1.8 |
47.1 |
2 |
46.3 |
2.3 |
54.9 |
8196 |
500 |

|