TiMF
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
36.7 |
25.0 |
18.5 |
12.3 |
7.4 |
Ohm/kM |
Insulation resistance |
min. |
1000 |
MOhm x km |
||||
Mutual capacitance |
max. |
150 |
nF/km |
||||
Capacitance unbalance |
max. |
500 |
pF/500m |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 1 minute |
2.0 kV A.C or 3.0 kV D.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
500 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.30 mm) |
|||||||
1x3x0.5 |
0.6 |
0.9 |
8.2 |
1.3 |
12.6 |
296 |
1000 |
2x3x0.5 |
0.6 |
0.9 |
13.4 |
1.4 |
18.0 |
480 |
1000 |
3x3x0.5 |
0.6 |
0.9 |
14.3 |
1.5 |
19.1 |
550 |
1000 |
4x3x0.5 |
0.6 |
1.25 |
15.8 |
1.5 |
21.3 |
750 |
1000 |
5x3x0.5 |
0.6 |
1.25 |
17.3 |
1.5 |
22.8 |
845 |
1000 |
6x3x0.5 |
0.6 |
1.25 |
19.0 |
1.6 |
24.7 |
949 |
500 |
7x3x0.5 |
0.6 |
1.25 |
19.0 |
1.6 |
24.7 |
987 |
500 |
10x3x0.5 |
0.6 |
1.6 |
24.6 |
1.7 |
31.2 |
1488 |
500 |
12x3x0.5 |
0.6 |
1.6 |
25.5 |
1.7 |
32.1 |
1606 |
500 |
16x3x0.5 |
0.6 |
2 |
28.5 |
1.8 |
36.1 |
2148 |
500 |
20x3x0.5 |
0.6 |
2 |
32.0 |
1.9 |
39.8 |
2484 |
500 |
24x3x0.5 |
0.6 |
2.5 |
36.1 |
2.0 |
45.1 |
3309 |
500 |
30x3x0.5 |
0.6 |
2.5 |
38.4 |
2.1 |
47.6 |
3664 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||||
1x3x0.75 |
0.6 |
0.9 |
8.7 |
1.4 |
13.3 |
321 |
1000 |
2x3x0.75 |
0.6 |
0.9 |
14.3 |
1.5 |
19.1 |
531 |
1000 |
3x3x0.75 |
0.6 |
0.9 |
15.2 |
1.5 |
20.0 |
604 |
1000 |
4x3x0.75 |
0.6 |
1.25 |
16.8 |
1.5 |
22.3 |
830 |
1000 |
5x3x0.75 |
0.6 |
1.25 |
18.5 |
1.6 |
24.2 |
945 |
1000 |
6x3x0.75 |
0.6 |
1.25 |
20.3 |
1.6 |
26.0 |
1052 |
500 |
7x3x0.75 |
0.6 |
1.25 |
20.3 |
1.6 |
26.0 |
1099 |
500 |
10x3x0.75 |
0.6 |
1.6 |
26.3 |
1.8 |
33.1 |
1665 |
500 |
12x3x0.75 |
0.6 |
1.6 |
27.2 |
1.8 |
34.0 |
1804 |
500 |
16x3x0.75 |
0.6 |
2 |
30.5 |
1.9 |
38.3 |
2416 |
500 |
20x3x0.75 |
0.6 |
2 |
34.3 |
2.0 |
42.3 |
2795 |
500 |
24x3x0.75 |
0.6 |
2.5 |
38.7 |
2.1 |
47.9 |
3711 |
500 |
30x3x0.75 |
0.6 |
2.5 |
41.1 |
2.1 |
50.3 |
4108 |
250 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||||
1x3x1 |
0.6 |
0.9 |
9.1 |
1.4 |
13.7 |
344 |
1000 |
2x3x1 |
0.6 |
0.9 |
15.0 |
1.5 |
19.8 |
567 |
1000 |
3x3x1 |
0.6 |
1.25 |
16.0 |
1.5 |
21.5 |
781 |
1000 |
4x3x1 |
0.6 |
1.25 |
17.7 |
1.6 |
23.4 |
904 |
1000 |
5x3x1 |
0.6 |
1.25 |
19.5 |
1.6 |
25.2 |
1020 |
500 |
6x3x1 |
0.6 |
1.25 |
21.4 |
1.6 |
27.1 |
1137 |
500 |
7x3x1 |
0.6 |
1.25 |
21.4 |
1.6 |
27.1 |
1194 |
500 |
10x3x1 |
0.6 |
2 |
27.7 |
1.8 |
35.3 |
2073 |
500 |
12x3x1 |
0.6 |
2 |
28.8 |
1.8 |
36.4 |
2223 |
500 |
16x3x1 |
0.6 |
2 |
32.2 |
1.9 |
40.0 |
2633 |
500 |
20x3x1 |
0.6 |
2.5 |
36.6 |
2.0 |
45.6 |
3536 |
500 |
24x3x1 |
0.6 |
2.5 |
40.9 |
2.1 |
50.1 |
4038 |
250 |
30x3x1 |
0.6 |
2.5 |
43.5 |
2.2 |
52.9 |
4553 |
250 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||||
1x3x1.5 |
0.6 |
0.9 |
9.7 |
1.4 |
14.3 |
380 |
1000 |
2x3x1.5 |
0.6 |
1.25 |
16.2 |
1.5 |
21.7 |
764 |
1000 |
3x3x1.5 |
0.6 |
1.25 |
17.3 |
1.6 |
23.0 |
890 |
1000 |
4x3x1.5 |
0.6 |
1.25 |
19.2 |
1.6 |
24.9 |
1024 |
500 |
5x3x1.5 |
0.6 |
1.25 |
21.1 |
1.6 |
26.8 |
1170 |
500 |
6x3x1.5 |
0.6 |
1.6 |
23.2 |
1.7 |
29.8 |
1510 |
500 |
7x3x1.5 |
0.6 |
1.6 |
23.2 |
1.7 |
29.8 |
1585 |
500 |
10x3x1.5 |
0.6 |
2 |
30.2 |
1.9 |
38.0 |
2376 |
500 |
12x3x1.5 |
0.6 |
2 |
31.3 |
1.9 |
39.1 |
2590 |
500 |
16x3x1.5 |
0.6 |
2.5 |
35.4 |
2.0 |
44.4 |
3546 |
500 |
20x3x1.5 |
0.6 |
2.5 |
39.8 |
2.1 |
49.0 |
4122 |
500 |
24x3x1.5 |
0.6 |
2.5 |
44.5 |
2.2 |
53.9 |
4705 |
250 |
30x3x1.5 |
0.6 |
3.15 |
47.4 |
2.3 |
58.3 |
6022 |
250 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||||
1x3x2.5 |
0.7 |
0.9 |
11.1 |
1.4 |
15.7 |
450 |
1000 |
2x3x2.5 |
0.7 |
1.25 |
18.7 |
1.6 |
24.4 |
932 |
1000 |
3x3x2.5 |
0.7 |
1.25 |
20.1 |
1.6 |
25.8 |
1085 |
500 |
4x3x2.5 |
0.7 |
1.6 |
22.2 |
1.7 |
28.8 |
1457 |
500 |
5x3x2.5 |
0.7 |
1.6 |
24.5 |
1.8 |
31.3 |
1670 |
500 |
6x3x2.5 |
0.7 |
1.6 |
27.0 |
1.8 |
33.8 |
1890 |
500 |
7x3x2.5 |
0.7 |
1.6 |
27.0 |
1.8 |
33.8 |
1998 |
500 |
10x3x2.5 |
0.7 |
2.5 |
35.6 |
2.0 |
44.6 |
3449 |
500 |
12x3x2.5 |
0.7 |
2.5 |
36.9 |
2.1 |
46.1 |
3782 |
500 |
16x3x2.5 |
0.7 |
2.5 |
41.4 |
2.2 |
50.8 |
4498 |
250 |
20x3x2.5 |
0.7 |
3.15 |
46.9 |
2.3 |
57.8 |
6003 |
250 |
24x3x2.5 |
0.7 |
3.15 |
52.5 |
2.5 |
63.8 |
6891 |
250 |
30x3x2.5 |
0.7 |
3.15 |
55.8 |
2.5 |
67.1 |
7788 |
250 |

|