Multi-Pair
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
36.7 |
25.0 |
18.5 |
12.3 |
7.4 |
Ohm/kM |
Insulation resistance |
min. |
100 |
MOhm x km |
||||
Mutual capacitance |
max. |
250 |
nF/km |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 1 minute |
2.0 kV A.C or 3.0 kV D.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
500 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.30 mm) |
|||||||
1x2x0.5 |
0.6 |
0.9 |
6.5 |
1.3 |
10.9 |
230 |
1000 |
2x2x0.5 |
0.6 |
0.9 |
9.2 |
1.4 |
13.8 |
327 |
1000 |
3x2x0.5 |
0.6 |
0.9 |
9.7 |
1.4 |
14.3 |
361 |
1000 |
4x2x0.5 |
0.6 |
0.9 |
10.6 |
1.4 |
15.2 |
404 |
1000 |
5x2x0.5 |
0.6 |
0.9 |
11.6 |
1.4 |
16.2 |
447 |
1000 |
6x2x0.5 |
0.6 |
0.9 |
12.6 |
1.5 |
17.4 |
499 |
1000 |
7x2x0.5 |
0.6 |
0.9 |
12.6 |
1.5 |
17.4 |
516 |
1000 |
10x2x0.5 |
0.6 |
1.25 |
16.1 |
1.5 |
21.6 |
796 |
1000 |
12x2x0.5 |
0.6 |
1.25 |
16.6 |
1.6 |
22.3 |
856 |
1000 |
16x2x0.5 |
0.6 |
1.25 |
18.5 |
1.6 |
24.2 |
999 |
1000 |
20x2x0.5 |
0.6 |
1.25 |
20.6 |
1.7 |
26.5 |
1155 |
500 |
24x2x0.5 |
0.6 |
1.6 |
23.0 |
1.7 |
29.6 |
1478 |
500 |
30x2x0.5 |
0.6 |
1.6 |
24.4 |
1.8 |
31.2 |
1663 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||||
1x2x0.75 |
0.6 |
0.9 |
6.9 |
1.3 |
11.3 |
251 |
1000 |
2x2x0.75 |
0.6 |
0.9 |
9.9 |
1.4 |
14.5 |
358 |
1000 |
3x2x0.75 |
0.6 |
0.9 |
10.5 |
1.4 |
15.1 |
398 |
1000 |
4x2x0.75 |
0.6 |
0.9 |
11.5 |
1.4 |
16.1 |
448 |
1000 |
5x2x0.75 |
0.6 |
0.9 |
12.5 |
1.5 |
17.3 |
511 |
1000 |
6x2x0.75 |
0.6 |
0.9 |
13.7 |
1.5 |
18.5 |
568 |
1000 |
7x2x0.75 |
0.6 |
0.9 |
13.7 |
1.5 |
18.5 |
592 |
1000 |
10x2x0.75 |
0.6 |
1.25 |
17.4 |
1.6 |
23.1 |
913 |
1000 |
12x2x0.75 |
0.6 |
1.25 |
18.0 |
1.6 |
23.7 |
988 |
1000 |
16x2x0.75 |
0.6 |
1.25 |
20.1 |
1.6 |
25.8 |
1147 |
500 |
20x2x0.75 |
0.6 |
1.6 |
22.5 |
1.7 |
29.1 |
1510 |
500 |
24x2x0.75 |
0.6 |
1.6 |
25.0 |
1.8 |
31.8 |
1731 |
500 |
30x2x0.75 |
0.6 |
1.6 |
26.6 |
1.8 |
33.4 |
1943 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||||
1x2x1 |
0.6 |
0.9 |
7.3 |
1.3 |
11.7 |
265 |
1000 |
2x2x1 |
0.6 |
0.9 |
10.5 |
1.4 |
15.1 |
385 |
1000 |
3x2x1 |
0.6 |
0.9 |
11.1 |
1.4 |
15.7 |
433 |
1000 |
4x2x1 |
0.6 |
0.9 |
12.2 |
1.4 |
16.8 |
495 |
1000 |
5x2x1 |
0.6 |
0.9 |
13.3 |
1.5 |
18.1 |
565 |
1000 |
6x2x1 |
0.6 |
0.9 |
14.5 |
1.5 |
19.3 |
629 |
1000 |
7x2x1 |
0.6 |
0.9 |
14.5 |
1.5 |
19.3 |
659 |
1000 |
10x2x1 |
0.6 |
1.25 |
18.6 |
1.6 |
24.3 |
1015 |
1000 |
12x2x1 |
0.6 |
1.25 |
19.3 |
1.6 |
25.0 |
1093 |
500 |
16x2x1 |
0.6 |
1.25 |
21.5 |
1.7 |
27.4 |
1309 |
500 |
20x2x1 |
0.6 |
1.6 |
24.1 |
1.7 |
30.7 |
1697 |
500 |
24x2x1 |
0.6 |
1.6 |
26.8 |
1.8 |
33.6 |
1944 |
500 |
30x2x1 |
0.6 |
2 |
28.5 |
1.9 |
36.3 |
2469 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||||
1x2x1.5 |
0.6 |
0.9 |
7.9 |
1.3 |
12.3 |
294 |
1000 |
2x2x1.5 |
0.6 |
0.9 |
11.4 |
1.4 |
16.0 |
436 |
1000 |
3x2x1.5 |
0.6 |
0.9 |
12.2 |
1.4 |
16.8 |
501 |
1000 |
4x2x1.5 |
0.6 |
0.9 |
13.4 |
1.5 |
18.2 |
584 |
1000 |
5x2x1.5 |
0.6 |
0.9 |
14.6 |
1.5 |
19.4 |
661 |
1000 |
6x2x1.5 |
0.6 |
1.25 |
16.0 |
1.6 |
21.7 |
879 |
1000 |
7x2x1.5 |
0.6 |
1.25 |
16.0 |
1.6 |
21.7 |
921 |
1000 |
10x2x1.5 |
0.6 |
1.25 |
20.6 |
1.7 |
26.5 |
1220 |
500 |
12x2x1.5 |
0.6 |
1.25 |
21.3 |
1.7 |
27.2 |
1322 |
500 |
16x2x1.5 |
0.6 |
1.6 |
23.8 |
1.8 |
30.6 |
1779 |
500 |
20x2x1.5 |
0.6 |
1.6 |
26.7 |
1.8 |
33.5 |
2064 |
500 |
24x2x1.5 |
0.6 |
2 |
29.7 |
1.9 |
37.5 |
2646 |
500 |
30x2x1.5 |
0.6 |
2 |
31.6 |
2.0 |
39.6 |
3014 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||||
1x2x2.5 |
0.7 |
0.9 |
9.1 |
1.4 |
13.7 |
357 |
1000 |
2x2x2.5 |
0.7 |
0.9 |
13.5 |
1.5 |
18.3 |
550 |
1000 |
3x2x2.5 |
0.7 |
0.9 |
14.4 |
1.5 |
19.2 |
640 |
1000 |
4x2x2.5 |
0.7 |
1.25 |
15.8 |
1.6 |
21.5 |
878 |
1000 |
5x2x2.5 |
0.7 |
1.25 |
17.4 |
1.6 |
23.1 |
1001 |
1000 |
6x2x2.5 |
0.7 |
1.25 |
19.1 |
1.6 |
24.8 |
1126 |
500 |
7x2x2.5 |
0.7 |
1.25 |
19.1 |
1.6 |
24.8 |
1191 |
500 |
10x2x2.5 |
0.7 |
1.6 |
24.7 |
1.8 |
31.5 |
1791 |
500 |
12x2x2.5 |
0.7 |
1.6 |
25.6 |
1.8 |
32.4 |
1965 |
500 |
16x2x2.5 |
0.7 |
2 |
28.6 |
1.9 |
36.4 |
2620 |
500 |
20x2x2.5 |
0.7 |
2 |
32.5 |
2.0 |
40.5 |
3130 |
500 |
24x2x2.5 |
0.7 |
2.5 |
36.2 |
2.1 |
45.4 |
4011 |
500 |
30x2x2.5 |
0.7 |
2.5 |
38.5 |
2.2 |
47.9 |
4535 |
500 |

|