Multi-Pair
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
36.7 |
25.0 |
18.5 |
12.3 |
7.4 |
Ohm/kM |
Insulation resistance |
min. |
100 |
MOhm x km |
||||
Mutual capacitance |
max. |
250 |
nF/km |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 1 minute |
2.0 kV A.C or 3.0 kV D.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
500 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.3 mm) |
|||||
1x2x0.5 |
0.6 |
0.9 |
6.3 |
44 |
1000 |
2x2x0.5 |
0.6 |
0.9 |
9.0 |
73 |
1000 |
3x2x0.5 |
0.6 |
1.0 |
9.7 |
96 |
1000 |
4x2x0.5 |
0.6 |
1.0 |
10.6 |
118 |
1000 |
5x2x0.5 |
0.6 |
1.0 |
11.6 |
140 |
1000 |
6x2x0.5 |
0.6 |
1.1 |
12.8 |
167 |
1000 |
7x2x0.5 |
0.6 |
1.1 |
12.8 |
185 |
1000 |
10x2x0.5 |
0.6 |
1.2 |
16.5 |
260 |
1000 |
12x2x0.5 |
0.6 |
1.2 |
17.0 |
298 |
1000 |
16x2x0.5 |
0.6 |
1.2 |
18.9 |
379 |
1000 |
20x2x0.5 |
0.6 |
1.3 |
21.2 |
469 |
1000 |
24x2x0.5 |
0.6 |
1.4 |
23.8 |
561 |
1000 |
30x2x0.5 |
0.6 |
1.4 |
25.2 |
676 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||
1x2x0.75 |
0.6 |
0.9 |
6.7 |
52 |
1000 |
2x2x0.75 |
0.6 |
1.0 |
9.9 |
92 |
1000 |
3x2x0.75 |
0.6 |
1.0 |
10.5 |
118 |
1000 |
4x2x0.75 |
0.6 |
1.0 |
11.5 |
146 |
1000 |
5x2x0.75 |
0.6 |
1.1 |
12.7 |
180 |
1000 |
6x2x0.75 |
0.6 |
1.1 |
13.9 |
209 |
1000 |
7x2x0.75 |
0.6 |
1.1 |
13.9 |
233 |
1000 |
10x2x0.75 |
0.6 |
1.2 |
17.8 |
329 |
1000 |
12x2x0.75 |
0.6 |
1.2 |
18.4 |
380 |
1000 |
16x2x0.75 |
0.6 |
1.3 |
20.7 |
494 |
1000 |
20x2x0.75 |
0.6 |
1.4 |
23.3 |
612 |
1000 |
24x2x0.75 |
0.6 |
1.5 |
26.0 |
732 |
500 |
30x2x0.75 |
0.6 |
1.5 |
27.6 |
886 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||
1x2x1 |
0.6 |
0.9 |
7.1 |
59 |
1000 |
2x2x1 |
0.6 |
1.0 |
10.5 |
106 |
1000 |
3x2x1 |
0.6 |
1.0 |
11.1 |
139 |
1000 |
4x2x1 |
0.6 |
1.0 |
12.2 |
173 |
1000 |
5x2x1 |
0.6 |
1.1 |
13.5 |
213 |
1000 |
6x2x1 |
0.6 |
1.1 |
14.7 |
249 |
1000 |
7x2x1 |
0.6 |
1.1 |
14.7 |
279 |
1000 |
10x2x1 |
0.6 |
1.2 |
19.0 |
395 |
1000 |
12x2x1 |
0.6 |
1.3 |
19.9 |
465 |
1000 |
16x2x1 |
0.6 |
1.3 |
22.1 |
597 |
1000 |
20x2x1 |
0.6 |
1.4 |
24.9 |
740 |
500 |
24x2x1 |
0.6 |
1.5 |
27.8 |
886 |
500 |
30x2x1 |
0.6 |
1.6 |
29.7 |
1088 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||
1x2x1.5 |
0.6 |
0.9 |
7.7 |
74 |
1000 |
2x2x1.5 |
0.6 |
1.0 |
11.4 |
135 |
1000 |
3x2x1.5 |
0.6 |
1.0 |
12.2 |
180 |
1000 |
4x2x1.5 |
0.6 |
1.1 |
13.6 |
232 |
1000 |
5x2x1.5 |
0.6 |
1.1 |
14.8 |
280 |
1000 |
6x2x1.5 |
0.6 |
1.2 |
16.4 |
334 |
1000 |
7x2x1.5 |
0.6 |
1.2 |
16.4 |
376 |
1000 |
10x2x1.5 |
0.6 |
1.3 |
21.2 |
533 |
1000 |
12x2x1.5 |
0.6 |
1.3 |
21.9 |
621 |
1000 |
16x2x1.5 |
0.6 |
1.4 |
24.6 |
811 |
500 |
20x2x1.5 |
0.6 |
1.5 |
27.7 |
1006 |
500 |
24x2x1.5 |
0.6 |
1.6 |
30.9 |
1205 |
500 |
30x2x1.5 |
0.6 |
1.7 |
33.0 |
1481 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||
1x2x2.5 |
0.7 |
0.9 |
8.9 |
103 |
1000 |
2x2x2.5 |
0.7 |
1.1 |
13.7 |
196 |
1000 |
3x2x2.5 |
0.7 |
1.1 |
14.6 |
266 |
1000 |
4x2x2.5 |
0.7 |
1.2 |
16.2 |
344 |
1000 |
5x2x2.5 |
0.7 |
1.2 |
17.8 |
417 |
1000 |
6x2x2.5 |
0.7 |
1.3 |
19.7 |
499 |
1000 |
7x2x2.5 |
0.7 |
1.3 |
19.7 |
564 |
1000 |
10x2x2.5 |
0.7 |
1.5 |
25.7 |
810 |
500 |
12x2x2.5 |
0.7 |
1.5 |
26.6 |
946 |
500 |
16x2x2.5 |
0.7 |
1.6 |
29.8 |
1237 |
500 |
20x2x2.5 |
0.7 |
1.7 |
33.5 |
1534 |
500 |
24x2x2.5 |
0.7 |
1.8 |
37.4 |
1836 |
500 |
30x2x2.5 |
0.7 |
1.9 |
39.9 |
2259 |
500 |

|