نمایش منو

NA2XSEYRY

613

3.6/6 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diamater

Insulation thickness

Diameter Under Armour

Armour Wire Diameter

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

Kg/Km

meter

3x25rm/16

5.8

2.5

34.7

2.0

2.3

43.3

3213

1000

3x35rm/16

7.0

2.5

37.4

2.0

2.3

46.0

3584

500

3x50rm/16

8.2

2.5

40.0

2.5

2.5

50.0

4460

500

3x70rm/16

9.9

2.5

43.9

2.5

2.6

54.1

5136

500

3x95rm/16

11.5

2.5

47.5

2.5

2.7

57.9

5811

500

3x120rm/16

13.0

2.5

50.7

2.5

2.8

61.3

6458

500

3x150rm/25

14.5

2.5

54.2

2.5

3.0

65.2

7214

250

3x185rm/25

16.1

2.5

58.5

2.5

3.0

69.5

8110

250

3x240rm/25

18.5

2.6

64.5

3.2

3.4

77.6

10451

250

3x300rm/25

20.6

2.8

70.9

3.2

3.5

84.2

12083

250

6/10 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diamater

Insulation thickness

Diameter Under Armour

Armour Wire Diameter

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

Kg/Km

meter

3x25rm/16

5.8

3.4

38.7

2.5

2.4

48.5

4157

500

3x35rm/16

7.0

3.4

41.3

2.5

2.5

51.3

4574

500

3x50rm/16

8.2

3.4

44.1

2.5

2.6

54.3

5061

500

3x70rm/16

9.9

3.4

47.9

2.5

2.7

58.3

5769

500

3x95rm/16

11.5

3.4

51.4

2.5

2.9

62.2

6477

500

3x120rm/16

13.0

3.4

54.8

2.5

3.0

65.8

7178

250

3x150rm/25

14.5

3.4

58.2

2.5

3.1

69.4

7935

250

3x185rm/25

16.1

3.4

62.5

3.2

3.2

75.2

9785

250

3x240rm/25

18.5

3.4

67.9

3.2

3.4

81.0

11169

250

3x300rm/25

20.6

3.4

73.3

3.2

3.6

86.8

13797

250

8.7/15 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diamater

Insulation thickness

Diameter Under Armour

Armour Wire Diameter

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

Kg/Km

meter

3x25rm/16

5.8

4.5

43.7

2.5

2.6

53.9

4851

500

3x35rm/16

7.0

4.5

46.2

2.5

2.7

56.6

5349

500

3x50rm/16

8.2

4.5

49.0

2.5

2.8

59.6

5853

500

3x70rm/16

9.9

4.5

52.9

2.5

3.0

63.9

6588

250

3x95rm/16

11.5

4.5

56.3

2.5

3.1

67.5

4845

500

3x120rm/16

13.0

4.5

59.7

2.5

3.1

70.9

7970

250

3x150rm/25

14.5

4.5

63.2

3.2

3.3

76.1

9724

250

3x185rm/25

16.1

4.5

67.5

3.2

3.4

80.6

10797

250

3x240rm/25

18.5

4.5

72.8

3.2

3.6

86.3

12230

250

3x300rm/25

20.6

4.5

78.4

4.0

3.8

94.0

15285

250

12/20 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diamater

Insulation thickness

Diameter Under Armour

Armour Wire Diameter

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

Kg/Km

meter

3x35rm/16

7.0

5.5

50.7

2.5

2.8

61.3

6042

500

3x50rm/16

8.2

5.5

53.5

2.5

2.9

64.3

6578

250

3x70rm/16

9.9

5.5

57.2

2.5

3.0

68.2

7292

250

3x95rm/16

11.5

5.5

60.8

3.2

3.2

73.5

8980

250

3x120rm/16

13.0

5.5

64.2

3.2

3.4

77.3

9823

250

3x150rm/25

14.5

5.5

67.5

3.2

3.4

80.6

10602

250

3x185rm/25

16.1

5.5

72.0

3.2

3.6

85.5

11778

250

3x240rm/25

18.5

5.5

77.3

4.0

3.8

92.9

14700

250