NA2XSEYRY
3.6/6 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Diameter Under Armour |
Armour Wire Diameter |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x25rm/16 |
5.8 |
2.5 |
34.7 |
2.0 |
2.3 |
43.3 |
3213 |
1000 |
3x35rm/16 |
7.0 |
2.5 |
37.4 |
2.0 |
2.3 |
46.0 |
3584 |
500 |
3x50rm/16 |
8.2 |
2.5 |
40.0 |
2.5 |
2.5 |
50.0 |
4460 |
500 |
3x70rm/16 |
9.9 |
2.5 |
43.9 |
2.5 |
2.6 |
54.1 |
5136 |
500 |
3x95rm/16 |
11.5 |
2.5 |
47.5 |
2.5 |
2.7 |
57.9 |
5811 |
500 |
3x120rm/16 |
13.0 |
2.5 |
50.7 |
2.5 |
2.8 |
61.3 |
6458 |
500 |
3x150rm/25 |
14.5 |
2.5 |
54.2 |
2.5 |
3.0 |
65.2 |
7214 |
250 |
3x185rm/25 |
16.1 |
2.5 |
58.5 |
2.5 |
3.0 |
69.5 |
8110 |
250 |
3x240rm/25 |
18.5 |
2.6 |
64.5 |
3.2 |
3.4 |
77.6 |
10451 |
250 |
3x300rm/25 |
20.6 |
2.8 |
70.9 |
3.2 |
3.5 |
84.2 |
12083 |
250 |
6/10 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Diameter Under Armour |
Armour Wire Diameter |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x25rm/16 |
5.8 |
3.4 |
38.7 |
2.5 |
2.4 |
48.5 |
4157 |
500 |
3x35rm/16 |
7.0 |
3.4 |
41.3 |
2.5 |
2.5 |
51.3 |
4574 |
500 |
3x50rm/16 |
8.2 |
3.4 |
44.1 |
2.5 |
2.6 |
54.3 |
5061 |
500 |
3x70rm/16 |
9.9 |
3.4 |
47.9 |
2.5 |
2.7 |
58.3 |
5769 |
500 |
3x95rm/16 |
11.5 |
3.4 |
51.4 |
2.5 |
2.9 |
62.2 |
6477 |
500 |
3x120rm/16 |
13.0 |
3.4 |
54.8 |
2.5 |
3.0 |
65.8 |
7178 |
250 |
3x150rm/25 |
14.5 |
3.4 |
58.2 |
2.5 |
3.1 |
69.4 |
7935 |
250 |
3x185rm/25 |
16.1 |
3.4 |
62.5 |
3.2 |
3.2 |
75.2 |
9785 |
250 |
3x240rm/25 |
18.5 |
3.4 |
67.9 |
3.2 |
3.4 |
81.0 |
11169 |
250 |
3x300rm/25 |
20.6 |
3.4 |
73.3 |
3.2 |
3.6 |
86.8 |
13797 |
250 |
8.7/15 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Diameter Under Armour |
Armour Wire Diameter |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x25rm/16 |
5.8 |
4.5 |
43.7 |
2.5 |
2.6 |
53.9 |
4851 |
500 |
3x35rm/16 |
7.0 |
4.5 |
46.2 |
2.5 |
2.7 |
56.6 |
5349 |
500 |
3x50rm/16 |
8.2 |
4.5 |
49.0 |
2.5 |
2.8 |
59.6 |
5853 |
500 |
3x70rm/16 |
9.9 |
4.5 |
52.9 |
2.5 |
3.0 |
63.9 |
6588 |
250 |
3x95rm/16 |
11.5 |
4.5 |
56.3 |
2.5 |
3.1 |
67.5 |
4845 |
500 |
3x120rm/16 |
13.0 |
4.5 |
59.7 |
2.5 |
3.1 |
70.9 |
7970 |
250 |
3x150rm/25 |
14.5 |
4.5 |
63.2 |
3.2 |
3.3 |
76.1 |
9724 |
250 |
3x185rm/25 |
16.1 |
4.5 |
67.5 |
3.2 |
3.4 |
80.6 |
10797 |
250 |
3x240rm/25 |
18.5 |
4.5 |
72.8 |
3.2 |
3.6 |
86.3 |
12230 |
250 |
3x300rm/25 |
20.6 |
4.5 |
78.4 |
4.0 |
3.8 |
94.0 |
15285 |
250 |
12/20 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Diameter Under Armour |
Armour Wire Diameter |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x35rm/16 |
7.0 |
5.5 |
50.7 |
2.5 |
2.8 |
61.3 |
6042 |
500 |
3x50rm/16 |
8.2 |
5.5 |
53.5 |
2.5 |
2.9 |
64.3 |
6578 |
250 |
3x70rm/16 |
9.9 |
5.5 |
57.2 |
2.5 |
3.0 |
68.2 |
7292 |
250 |
3x95rm/16 |
11.5 |
5.5 |
60.8 |
3.2 |
3.2 |
73.5 |
8980 |
250 |
3x120rm/16 |
13.0 |
5.5 |
64.2 |
3.2 |
3.4 |
77.3 |
9823 |
250 |
3x150rm/25 |
14.5 |
5.5 |
67.5 |
3.2 |
3.4 |
80.6 |
10602 |
250 |
3x185rm/25 |
16.1 |
5.5 |
72.0 |
3.2 |
3.6 |
85.5 |
11778 |
250 |
3x240rm/25 |
18.5 |
5.5 |
77.3 |
4.0 |
3.8 |
92.9 |
14700 |
250 |

|