N2XSEY
3.6/6 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x25rm/16 |
5.8 |
2.5 |
2.2 |
39.1 |
2419 |
500 |
3x35rm/16 |
7.0 |
2.5 |
2.3 |
41.8 |
2899 |
500 |
3x50rm/16 |
8.2 |
2.5 |
2.3 |
44.8 |
3552 |
500 |
3x70rm/16 |
9.9 |
2.5 |
2.4 |
48.7 |
4417 |
500 |
3x95rm/16 |
11.5 |
2.5 |
2.5 |
52.3 |
5412 |
500 |
3x120rm/16 |
13.0 |
2.5 |
2.6 |
56.1 |
6468 |
500 |
3x150rm/25 |
14.5 |
2.5 |
2.8 |
59.8 |
7637 |
500 |
3x185rm/25 |
16.1 |
2.5 |
2.9 |
64.3 |
9078 |
250 |
3x240rm/25 |
18.5 |
2.6 |
3.2 |
70.4 |
11264 |
250 |
3x300rm/25 |
20.6 |
2.8 |
3.4 |
77.5 |
13852 |
250 |
6/10 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x25rm/16 |
5.8 |
3.4 |
2.3 |
43.1 |
2780 |
500 |
3x35rm/16 |
7.0 |
3.4 |
2.3 |
46.1 |
3320 |
500 |
3x50rm/16 |
8.2 |
3.4 |
2.4 |
48.9 |
3972 |
500 |
3x70rm/16 |
9.9 |
3.4 |
2.6 |
52.9 |
4892 |
500 |
3x95rm/16 |
11.5 |
3.4 |
2.7 |
57.0 |
5987 |
500 |
3x120rm/16 |
13.0 |
3.4 |
2.8 |
60.4 |
7010 |
500 |
3x150rm/25 |
14.5 |
3.4 |
2.9 |
63.8 |
8182 |
250 |
3x185rm/25 |
16.1 |
3.4 |
3.0 |
68.3 |
9661 |
250 |
3x240rm/25 |
18.5 |
3.4 |
3.2 |
74.3 |
11886 |
250 |
3x300rm/25 |
20.6 |
3.4 |
3.3 |
79.9 |
14236 |
250 |
8.7/15 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x25rm/16 |
5.8 |
4.5 |
2.4 |
48.5 |
3330 |
500 |
3x35rm/16 |
7.0 |
4.5 |
2.5 |
51.2 |
3868 |
500 |
3x50rm/16 |
8.2 |
4.5 |
2.7 |
54.6 |
4639 |
500 |
3x70rm/16 |
9.9 |
4.5 |
2.7 |
58.3 |
5555 |
500 |
3x95rm/16 |
11.5 |
4.5 |
2.9 |
62.1 |
6660 |
500 |
3x120rm/16 |
13.0 |
4.5 |
3.0 |
65.5 |
7720 |
500 |
3x150rm/25 |
14.5 |
4.5 |
3.1 |
69.0 |
8517 |
250 |
3x185rm/25 |
16.1 |
4.5 |
3.2 |
73.9 |
10533 |
250 |
3x240rm/25 |
18.5 |
4.5 |
3.4 |
79.4 |
12742 |
250 |
12/20 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x35rm/16 |
7.0 |
5.5 |
2.7 |
56.3 |
4499 |
500 |
3x50rm/16 |
8.2 |
5.5 |
2.8 |
59.1 |
5211 |
500 |
3x70rm/16 |
9.9 |
5.5 |
2.9 |
63.0 |
6174 |
500 |
3x95rm/16 |
11.5 |
5.5 |
3.0 |
66.6 |
7277 |
250 |
3x120rm/16 |
13.0 |
5.5 |
3.1 |
70.0 |
8367 |
250 |
3x150rm/25 |
14.5 |
5.5 |
3.2 |
73.9 |
9694 |
250 |
3x185rm/25 |
16.1 |
5.5 |
3.3 |
78.4 |
11283 |
250 |
3x240rm/25 |
18.5 |
5.5 |
3.6 |
84.1 |
13575 |
250 |

|