TiMF
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
36.7 |
25.0 |
18.5 |
12.3 |
7.4 |
Ohm/kM |
Insulation resistance |
min. |
1000 |
MOhm x km |
||||
Mutual capacitance |
max. |
150 |
nF/km |
||||
Capacitance unbalance |
max. |
500 |
pF/500m |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 1 minute |
2.0 kV A.C or 3.0 kV D.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
500 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Lead Sheath Thickness |
Diameter Over Lead Sheath |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.30 mm) |
|||||||||
1x3x0.5 |
0.6 |
0.9 |
10.0 |
0.9 |
10.2 |
1.4 |
14.8 |
623 |
1000 |
2x3x0.5 |
0.6 |
1.0 |
15.4 |
0.9 |
15.4 |
1.5 |
20.2 |
995 |
1000 |
3x3x0.5 |
0.6 |
1.0 |
16.3 |
0.9 |
16.3 |
1.5 |
21.1 |
1078 |
1000 |
4x3x0.5 |
0.6 |
1.1 |
18.0 |
0.9 |
17.8 |
1.6 |
22.8 |
1258 |
1000 |
5x3x0.5 |
0.6 |
1.1 |
19.5 |
1.25 |
19.3 |
1.6 |
25.0 |
1543 |
1000 |
6x3x0.5 |
0.6 |
1.1 |
21.2 |
1.25 |
21.0 |
1.6 |
26.7 |
1691 |
1000 |
7x3x0.5 |
0.6 |
1.1 |
21.2 |
1.25 |
21.0 |
1.6 |
26.7 |
1729 |
1000 |
10x3x0.5 |
0.6 |
1.3 |
27.2 |
1.25 |
26.6 |
1.8 |
32.7 |
2379 |
500 |
12x3x0.5 |
0.6 |
1.3 |
28.1 |
1.25 |
27.5 |
1.8 |
33.6 |
2518 |
500 |
16x3x0.5 |
0.6 |
1.4 |
31.3 |
1.6 |
30.5 |
1.9 |
37.5 |
3208 |
500 |
20x3x0.5 |
0.6 |
1.4 |
34.8 |
1.6 |
34.0 |
1.9 |
41.0 |
3653 |
500 |
24x3x0.5 |
0.6 |
1.5 |
39.1 |
2 |
38.5 |
2.0 |
46.5 |
4672 |
500 |
30x3x0.5 |
0.6 |
1.6 |
41.6 |
2 |
40.8 |
2.1 |
49.0 |
5233 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||||||
1x3x0.75 |
0.6 |
0.9 |
10.5 |
0.9 |
10.7 |
1.4 |
15.3 |
664 |
1000 |
2x3x0.75 |
0.6 |
1.0 |
16.3 |
0.9 |
16.3 |
1.5 |
21.1 |
1066 |
1000 |
3x3x0.75 |
0.6 |
1.1 |
17.4 |
0.9 |
17.2 |
1.5 |
22.0 |
1217 |
1000 |
4x3x0.75 |
0.6 |
1.1 |
19.0 |
1.25 |
18.8 |
1.6 |
24.5 |
1511 |
1000 |
5x3x0.75 |
0.6 |
1.1 |
20.7 |
1.25 |
20.5 |
1.6 |
26.2 |
1670 |
1000 |
6x3x0.75 |
0.6 |
1.2 |
22.7 |
1.25 |
22.3 |
1.7 |
28.2 |
1919 |
1000 |
7x3x0.75 |
0.6 |
1.2 |
22.7 |
1.25 |
22.3 |
1.7 |
28.2 |
1967 |
1000 |
10x3x0.75 |
0.6 |
1.3 |
28.9 |
1.25 |
28.3 |
1.8 |
34.4 |
2616 |
500 |
12x3x0.75 |
0.6 |
1.3 |
29.8 |
1.25 |
29.2 |
1.8 |
35.3 |
2778 |
500 |
16x3x0.75 |
0.6 |
1.4 |
33.3 |
1.6 |
32.5 |
1.9 |
39.5 |
3552 |
500 |
20x3x0.75 |
0.6 |
1.5 |
37.3 |
1.6 |
36.7 |
2.0 |
43.9 |
4224 |
500 |
24x3x0.75 |
0.6 |
1.6 |
41.9 |
2 |
41.1 |
2.1 |
49.3 |
5311 |
500 |
30x3x0.75 |
0.6 |
1.7 |
44.5 |
2 |
43.5 |
2.2 |
51.9 |
5958 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Lead Sheath Thickness |
Diameter Over Lead Sheath |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||||||
1x3x1 |
0.6 |
0.9 |
10.9 |
0.9 |
11.1 |
1.4 |
15.7 |
689 |
1000 |
2x3x1 |
0.6 |
1.1 |
17.2 |
0.9 |
17.0 |
1.5 |
21.8 |
1171 |
1000 |
3x3x1 |
0.6 |
1.1 |
18.2 |
0.9 |
18.0 |
1.6 |
23.0 |
1295 |
1000 |
4x3x1 |
0.6 |
1.1 |
19.9 |
1.25 |
19.7 |
1.6 |
25.4 |
1597 |
1000 |
5x3x1 |
0.6 |
1.2 |
21.9 |
1.25 |
21.5 |
1.7 |
27.4 |
1850 |
1000 |
6x3x1 |
0.6 |
1.2 |
23.8 |
1.25 |
23.4 |
1.7 |
29.3 |
2033 |
500 |
7x3x1 |
0.6 |
1.2 |
23.8 |
1.25 |
23.4 |
1.7 |
29.3 |
2090 |
500 |
10x3x1 |
0.6 |
1.3 |
30.3 |
1.6 |
29.7 |
1.8 |
36.5 |
3022 |
500 |
12x3x1 |
0.6 |
1.4 |
31.6 |
1.6 |
30.8 |
1.9 |
37.8 |
3317 |
500 |
16x3x1 |
0.6 |
1.4 |
35.0 |
1.6 |
34.2 |
1.9 |
41.2 |
3817 |
500 |
20x3x1 |
0.6 |
1.5 |
39.6 |
2 |
39.0 |
2.1 |
47.2 |
4946 |
500 |
24x3x1 |
0.6 |
1.6 |
44.1 |
2 |
43.3 |
2.2 |
51.7 |
5728 |
500 |
30x3x1 |
0.6 |
1.7 |
46.9 |
2 |
45.9 |
2.2 |
54.3 |
6449 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||||||
1x3x1.5 |
0.6 |
0.9 |
11.5 |
0.9 |
11.7 |
1.4 |
16.3 |
748 |
1000 |
2x3x1.5 |
0.6 |
1.1 |
18.4 |
1.25 |
18.2 |
1.6 |
23.9 |
1444 |
1000 |
3x3x1.5 |
0.6 |
1.1 |
19.5 |
1.25 |
19.3 |
1.6 |
25.0 |
1597 |
1000 |
4x3x1.5 |
0.6 |
1.2 |
21.6 |
1.25 |
21.2 |
1.7 |
27.1 |
1862 |
1000 |
5x3x1.5 |
0.6 |
1.2 |
23.5 |
1.25 |
23.1 |
1.7 |
29.0 |
2067 |
500 |
6x3x1.5 |
0.6 |
1.3 |
25.8 |
1.25 |
25.2 |
1.7 |
31.1 |
2361 |
500 |
7x3x1.5 |
0.6 |
1.3 |
25.8 |
1.25 |
25.2 |
1.7 |
31.1 |
2435 |
500 |
10x3x1.5 |
0.6 |
1.4 |
33.0 |
1.6 |
32.2 |
1.9 |
39.2 |
3526 |
500 |
12x3x1.5 |
0.6 |
1.4 |
34.1 |
1.6 |
33.3 |
1.9 |
40.3 |
3766 |
500 |
16x3x1.5 |
0.6 |
1.5 |
38.4 |
2 |
37.8 |
2.1 |
46.0 |
4965 |
500 |
20x3x1.5 |
0.6 |
1.6 |
43.0 |
2 |
42.2 |
2.2 |
50.6 |
5807 |
500 |
24x3x1.5 |
0.6 |
1.7 |
47.9 |
2.5 |
46.9 |
2.3 |
56.5 |
7213 |
500 |
30x3x1.5 |
0.6 |
1.8 |
51.0 |
2.5 |
50.2 |
2.4 |
60.0 |
8214 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Lead Sheath Thickness |
Diameter Over Lead Sheath |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||||||
1x3x2.5 |
0.7 |
1.0 |
13.1 |
0.9 |
13.1 |
1.5 |
17.9 |
914 |
1000 |
2x3x2.5 |
0.7 |
1.2 |
21.1 |
1.25 |
20.7 |
1.7 |
26.6 |
1775 |
1000 |
3x3x2.5 |
0.7 |
1.2 |
22.5 |
1.25 |
22.1 |
1.7 |
28.0 |
1976 |
1000 |
4x3x2.5 |
0.7 |
1.2 |
24.6 |
1.25 |
24.2 |
1.7 |
30.1 |
2237 |
500 |
5x3x2.5 |
0.7 |
1.3 |
27.1 |
1.25 |
26.5 |
1.8 |
32.6 |
2596 |
500 |
6x3x2.5 |
0.7 |
1.4 |
29.8 |
1.25 |
29.0 |
1.8 |
35.1 |
2976 |
500 |
7x3x2.5 |
0.7 |
1.4 |
29.8 |
1.25 |
29.0 |
1.8 |
35.1 |
3084 |
500 |
10x3x2.5 |
0.7 |
1.6 |
38.8 |
2 |
38.0 |
2.1 |
46.2 |
5035 |
500 |
12x3x2.5 |
0.7 |
1.6 |
40.1 |
2 |
39.3 |
2.1 |
47.5 |
5384 |
500 |
16x3x2.5 |
0.7 |
1.7 |
44.8 |
2 |
43.8 |
2.2 |
52.2 |
6394 |
500 |
20x3x2.5 |
0.7 |
1.8 |
50.5 |
2.5 |
49.7 |
2.4 |
59.5 |
8251 |
500 |
24x3x2.5 |
0.7 |
2.0 |
56.5 |
2.5 |
55.3 |
2.5 |
65.3 |
9655 |
250 |
30x3x2.5 |
0.7 |
2.0 |
59.8 |
3.15 |
58.6 |
2.6 |
70.1 |
11578 |
250 |

|