Show Menu

Multi-Triple

 

Criteria

Standard Values

Unit

Conductor cross section

Nominal

0.5

0.75

1

1.5

2.5

mm²

Conductor DC Resistance @ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

1000

MOhm x km

Mutual capacitance

max.

150

nF/km

Capacitance unbalance

max.

500

pF/500m

L/R (ratio)

max.

25

25

25

40

60

microH/Ohm

Test voltage :

for 1 minute

2.0 kV A.C or 3.0 kV D.C

K.V

core to core

core to screen

Operating voltage U(rms)

 

500

V

Nominal cross section area of conductor

Insulation thickness

Lead Sheath Thickness

Diameter Over Lead Sheath

Armour Wire Diameter

Diameter Under Armour

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

mm

Kg/Km

meter

Conductor : 0.5 mm2 (7x0.30 mm)

1x3x0.5

0.6

0.9

9.7

0.9

9.9

1.4

14.5

594

1000

2x3x0.5

0.6

1.0

13.9

0.9

13.9

1.5

18.7

889

1000

3x3x0.5

0.6

1.0

14.7

0.9

14.7

1.5

19.5

958

1000

4x3x0.5

0.6

1.0

16.0

0.9

16.0

1.5

20.8

1057

1000

5x3x0.5

0.6

1.1

17.5

0.9

17.3

1.5

22.1

1213

1000

6x3x0.5

0.6

1.1

18.9

1.25

18.7

1.6

24.4

1476

1000

7x3x0.5

0.6

1.1

18.9

1.25

18.7

1.6

24.4

1505

1000

10x3x0.5

0.6

1.2

24.0

1.25

23.6

1.7

29.5

1990

500

12x3x0.5

0.6

1.2

24.7

1.25

24.3

1.7

30.2

2092

500

16x3x0.5

0.6

1.3

27.5

1.25

26.9

1.8

33.0

2480

500

20x3x0.5

0.6

1.3

30.6

1.6

30.0

1.8

36.8

3029

500

24x3x0.5

0.6

1.4

34.0

1.6

33.2

1.9

40.2

3502

500

30x3x0.5

0.6

1.5

36.2

1.6

35.6

2.0

42.8

4005

500

Conductor : 0.75 mm2 (7x0.37 mm)

1x3x0.75

0.6

0.9

10.1

0.9

10.3

1.4

14.9

634

1000

2x3x0.75

0.6

1.0

14.7

0.9

14.7

1.5

19.5

956

1000

3x3x0.75

0.6

1.0

15.5

0.9

15.5

1.5

20.3

1043

1000

4x3x0.75

0.6

1.1

17.1

0.9

16.9

1.5

21.7

1203

1000

5x3x0.75

0.6

1.1

18.6

0.9

18.4

1.6

23.4

1338

1000

6x3x0.75

0.6

1.1

20.1

1.25

19.9

1.6

25.6

1623

1000

7x3x0.75

0.6

1.1

20.1

1.25

19.9

1.6

25.6

1661

1000

10x3x0.75

0.6

1.2

25.5

1.25

25.1

1.7

31.0

2199

500

12x3x0.75

0.6

1.3

26.6

1.25

26.0

1.7

31.9

2405

500

16x3x0.75

0.6

1.3

29.4

1.25

28.8

1.8

34.9

2776

500

20x3x0.75

0.6

1.4

32.9

1.6

32.1

1.9

39.1

3505

500

24x3x0.75

0.6

1.5

36.6

1.6

36.0

2.0

43.2

4103

500

30x3x0.75

0.6

1.5

39.1

2

38.5

2.1

46.7

4935

500

Nominal cross section area of conductor

Insulation thickness

Lead Sheath Thickness

Diameter Over Lead Sheath

Armour Wire Diameter

Diameter Under Armour

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)

1x3x1

0.6

0.9

10.5

0.9

10.7

1.4

15.3

660

1000

2x3x1

0.6

1.0

15.4

0.9

15.4

1.5

20.2

1005

1000

3x3x1

0.6

1.0

16.3

0.9

16.3

1.5

21.1

1102

1000

4x3x1

0.6

1.1

17.9

0.9

17.7

1.6

22.7

1290

1000

5x3x1

0.6

1.1

19.5

1.25

19.3

1.6

25.0

1573

1000

6x3x1

0.6

1.1

21.1

1.25

20.9

1.6

26.6

1730

1000

7x3x1

0.6

1.1

21.1

1.25

20.9

1.6

26.6

1777

1000

10x3x1

0.6

1.3

27.1

1.25

26.5

1.8

32.6

2451

500

12x3x1

0.6

1.3

28.0

1.25

27.4

1.8

33.5

2617

500

16x3x1

0.6

1.3

31.0

1.6

30.4

1.9

37.4

3257

500

20x3x1

0.6

1.4

34.7

1.6

33.9

1.9

40.9

3804

500

24x3x1

0.6

1.5

38.6

2

38.0

2.0

46.0

4795

500

30x3x1

0.6

1.6

41.5

2

40.7

2.1

48.9

5485

500

Conductor : 1.5 mm2 (7x0.53 mm)

1x3x1.5

0.6

0.9

11.2

0.9

11.4

1.4

16.0

718

1000

2x3x1.5

0.6

1.1

16.7

0.9

16.5

1.5

21.3

1166

1000

3x3x1.5

0.6

1.1

17.7

0.9

17.5

1.6

22.5

1296

1000

4x3x1.5

0.6

1.1

19.3

1.25

19.1

1.6

24.8

1605

1000

5x3x1.5

0.6

1.2

21.2

1.25

20.8

1.6

26.5

1843

1000

6x3x1.5

0.6

1.2

23.0

1.25

22.6

1.7

28.5

2042

1000

7x3x1.5

0.6

1.2

23.0

1.25

22.6

1.7

28.5

2106

1000

10x3x1.5

0.6

1.3

29.3

1.25

28.7

1.8

34.8

2826

500

12x3x1.5

0.6

1.4

30.5

1.6

29.7

1.9

36.7

3350

500

16x3x1.5

0.6

1.4

33.8

1.6

33.0

1.9

40.0

3877

500

20x3x1.5

0.6

1.5

38.3

2

37.7

2.1

45.9

5010

500

24x3x1.5

0.6

1.6

42.5

2

41.7

2.1

49.9

5797

500

30x3x1.5

0.6

1.7

45.3

2

44.3

2.2

52.7

6552

500

Nominal cross section area of conductor

Insulation thickness

Lead Sheath Thickness

Diameter Over Lead Sheath

Armour Wire Diameter

Diameter Under Armour

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

mm

Kg/Km

meter

Conductor : 2.5 mm2 (7x0.67 mm)

1x3x2.5

0.7

1.0

12.7

0.9

12.7

1.5

17.5

882

1000

2x3x2.5

0.7

1.1

19.0

1.25

18.8

1.6

24.5

1542

1000

3x3x2.5

0.7

1.1

20.2

1.25

20.0

1.6

25.7

1721

1000

4x3x2.5

0.7

1.2

22.3

1.25

21.9

1.7

27.8

2028

1000

5x3x2.5

0.7

1.2

24.3

1.25

23.9

1.7

29.8

2262

500

6x3x2.5

0.7

1.3

26.7

1.25

26.1

1.8

32.2

2613

500

7x3x2.5

0.7

1.3

26.7

1.25

26.1

1.8

32.2

2709

500

10x3x2.5

0.7

1.5

34.4

1.6

33.8

2.0

41.0

4055

500

12x3x2.5

0.7

1.5

35.5

1.6

34.9

2.0

42.1

4348

500

16x3x2.5

0.7

1.6

40.0

2

39.2

2.1

47.4

5625

500

20x3x2.5

0.7

1.7

44.8

2

43.8

2.2

52.2

6623

500

24x3x2.5

0.7

1.8

49.9

2.5

49.1

2.4

58.9

8278

500

30x3x2.5

0.7

1.9

53.5

2.5

52.5

2.4

62.3

9446

500