Multi-Core
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
36.7 |
25.0 |
18.5 |
12.3 |
7.4 |
Ohm/kM |
Insulation resistance |
min. |
1000 |
MOhm x km |
||||
Mutual capacitance |
max. |
150 |
nF/km |
||||
Capacitance unbalance |
max. |
500 |
pF/500m |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 1 minute |
2.0 kV A.C or 3.0 kV D.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
500 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Armour Tape Thickness |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.30 mm) |
|||||||
2x0.5 |
0.6 |
0.2 |
7.4 |
1.3 |
10.8 |
165 |
1000 |
3x0.5 |
0.6 |
0.2 |
7.9 |
1.3 |
11.3 |
181 |
1000 |
4x0.5 |
0.6 |
0.2 |
8.5 |
1.3 |
11.9 |
202 |
1000 |
5x0.5 |
0.6 |
0.2 |
9.3 |
1.3 |
12.7 |
224 |
1000 |
6x0.5 |
0.6 |
0.2 |
10.0 |
1.4 |
13.6 |
252 |
1000 |
7x0.5 |
0.6 |
0.2 |
10.0 |
1.4 |
13.6 |
261 |
1000 |
8x0.5 |
0.6 |
0.2 |
11.6 |
1.4 |
15.2 |
297 |
1000 |
10x0.5 |
0.6 |
0.2 |
12.6 |
1.4 |
16.2 |
334 |
1000 |
12x0.5 |
0.6 |
0.2 |
13.0 |
1.4 |
16.6 |
360 |
1000 |
16x0.5 |
0.6 |
0.2 |
14.4 |
1.4 |
18.0 |
422 |
1000 |
20x0.5 |
0.6 |
0.2 |
16.0 |
1.5 |
19.8 |
495 |
1000 |
24x0.5 |
0.6 |
0.2 |
17.8 |
1.5 |
21.6 |
563 |
1000 |
30x0.5 |
0.6 |
0.2 |
18.8 |
1.5 |
22.6 |
638 |
1000 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||||
2x0.75 |
0.6 |
0.2 |
7.9 |
1.3 |
11.3 |
178 |
1000 |
3x0.75 |
0.6 |
0.2 |
8.3 |
1.3 |
11.7 |
198 |
1000 |
4x0.75 |
0.6 |
0.2 |
9.0 |
1.3 |
12.4 |
223 |
1000 |
5x0.75 |
0.6 |
0.2 |
9.8 |
1.3 |
13.2 |
249 |
1000 |
6x0.75 |
0.6 |
0.2 |
10.7 |
1.4 |
14.3 |
281 |
1000 |
7x0.75 |
0.6 |
0.2 |
10.7 |
1.4 |
14.3 |
294 |
1000 |
8x0.75 |
0.6 |
0.2 |
12.3 |
1.4 |
15.9 |
335 |
1000 |
10x0.75 |
0.6 |
0.2 |
13.4 |
1.4 |
17.0 |
379 |
1000 |
12x0.75 |
0.6 |
0.2 |
13.9 |
1.4 |
17.5 |
412 |
1000 |
16x0.75 |
0.6 |
0.2 |
15.4 |
1.5 |
19.2 |
495 |
1000 |
20x0.75 |
0.6 |
0.2 |
17.2 |
1.5 |
21.0 |
575 |
1000 |
24x0.75 |
0.6 |
0.2 |
19.0 |
1.5 |
22.8 |
658 |
1000 |
30x0.75 |
0.6 |
0.2 |
20.2 |
1.6 |
24.2 |
762 |
1000 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Tape Thickness |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||||
2x1 |
0.6 |
0.2 |
8.2 |
1.3 |
11.6 |
190 |
1000 |
3x1 |
0.6 |
0.2 |
8.7 |
1.3 |
12.1 |
213 |
1000 |
4x1 |
0.6 |
0.2 |
9.5 |
1.3 |
12.9 |
242 |
1000 |
5x1 |
0.6 |
0.2 |
10.3 |
1.4 |
13.9 |
277 |
1000 |
6x1 |
0.6 |
0.2 |
11.2 |
1.4 |
14.8 |
307 |
1000 |
7x1 |
0.6 |
0.2 |
11.2 |
1.4 |
14.8 |
323 |
1000 |
8x1 |
0.6 |
0.2 |
13.0 |
1.4 |
16.6 |
369 |
1000 |
10x1 |
0.6 |
0.2 |
14.2 |
1.4 |
17.8 |
420 |
1000 |
12x1 |
0.6 |
0.2 |
14.6 |
1.4 |
18.2 |
459 |
1000 |
16x1 |
0.6 |
0.2 |
16.2 |
1.5 |
20.0 |
555 |
1000 |
20x1 |
0.6 |
0.2 |
18.1 |
1.5 |
21.9 |
649 |
1000 |
24x1 |
0.6 |
0.2 |
20.1 |
1.6 |
24.1 |
755 |
1000 |
30x1 |
0.6 |
0.2 |
21.3 |
1.6 |
25.3 |
868 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||||
2x1.5 |
0.6 |
0.2 |
8.8 |
1.3 |
12.2 |
212 |
1000 |
3x1.5 |
0.6 |
0.2 |
9.4 |
1.3 |
12.8 |
242 |
1000 |
4x1.5 |
0.6 |
0.2 |
10.2 |
1.4 |
13.8 |
283 |
1000 |
5x1.5 |
0.6 |
0.2 |
11.1 |
1.4 |
14.7 |
320 |
1000 |
6x1.5 |
0.6 |
0.2 |
12.1 |
1.4 |
15.7 |
358 |
1000 |
7x1.5 |
0.6 |
0.2 |
12.1 |
1.4 |
15.7 |
379 |
1000 |
8x1.5 |
0.6 |
0.2 |
14.1 |
1.4 |
17.7 |
435 |
1000 |
10x1.5 |
0.6 |
0.2 |
15.4 |
1.5 |
19.2 |
507 |
1000 |
12x1.5 |
0.6 |
0.2 |
15.9 |
1.5 |
19.7 |
558 |
1000 |
16x1.5 |
0.6 |
0.2 |
17.7 |
1.5 |
21.5 |
673 |
1000 |
20x1.5 |
0.6 |
0.2 |
19.7 |
1.6 |
23.7 |
803 |
1000 |
24x1.5 |
0.6 |
0.2 |
21.9 |
1.6 |
25.9 |
926 |
500 |
30x1.5 |
0.6 |
0.2 |
23.2 |
1.6 |
27.2 |
1076 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Tape Thickness |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||||
2x2.5 |
0.7 |
0.2 |
10.1 |
1.4 |
13.7 |
262 |
1000 |
3x2.5 |
0.7 |
0.2 |
10.7 |
1.4 |
14.3 |
305 |
1000 |
4x2.5 |
0.7 |
0.2 |
11.7 |
1.4 |
15.3 |
354 |
1000 |
5x2.5 |
0.7 |
0.2 |
12.8 |
1.4 |
16.4 |
405 |
1000 |
6x2.5 |
0.7 |
0.2 |
14.0 |
1.4 |
17.6 |
457 |
1000 |
7x2.5 |
0.7 |
0.2 |
14.0 |
1.4 |
17.6 |
489 |
1000 |
8x2.5 |
0.7 |
0.2 |
16.3 |
1.5 |
20.1 |
570 |
1000 |
10x2.5 |
0.7 |
0.2 |
17.8 |
1.5 |
21.6 |
661 |
1000 |
12x2.5 |
0.7 |
0.2 |
18.5 |
1.5 |
22.3 |
736 |
1000 |
16x2.5 |
0.7 |
0.2 |
20.6 |
1.6 |
24.6 |
910 |
500 |
20x2.5 |
0.7 |
0.2 |
23.0 |
1.6 |
27.0 |
1082 |
500 |
24x2.5 |
0.7 |
0.2 |
25.6 |
1.7 |
29.8 |
1267 |
500 |
30x2.5 |
0.7 |
0.2 |
27.2 |
1.7 |
31.4 |
1487 |
500 |

|