PiMF
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
36.7 |
25.0 |
18.5 |
12.3 |
7.4 |
Ohm/kM |
Insulation resistance |
min. |
100 |
MOhm x km |
||||
Mutual capacitance |
max. |
250 |
nF/km |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 1 minute |
2.0 kV A.C or 3.0 kV D.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
500 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.3 mm) |
|||||
1x2x0.5 |
0.6 |
0.9 |
6.6 |
54 |
1000 |
2x2x0.5 |
0.6 |
1.0 |
10.4 |
98 |
1000 |
3x2x0.5 |
0.6 |
1.0 |
11.0 |
126 |
1000 |
4x2x0.5 |
0.6 |
1.0 |
12.1 |
156 |
1000 |
5x2x0.5 |
0.6 |
1.1 |
13.4 |
192 |
1000 |
6x2x0.5 |
0.6 |
1.1 |
14.6 |
224 |
1000 |
7x2x0.5 |
0.6 |
1.1 |
14.6 |
250 |
1000 |
10x2x0.5 |
0.6 |
1.2 |
18.9 |
353 |
1000 |
12x2x0.5 |
0.6 |
1.3 |
19.8 |
416 |
1000 |
16x2x0.5 |
0.6 |
1.3 |
21.9 |
531 |
1000 |
20x2x0.5 |
0.6 |
1.4 |
24.7 |
657 |
500 |
24x2x0.5 |
0.6 |
1.5 |
27.6 |
787 |
500 |
30x2x0.5 |
0.6 |
1.6 |
29.5 |
963 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||
1x2x0.75 |
0.6 |
0.9 |
7.1 |
62 |
1000 |
2x2x0.75 |
0.6 |
1.0 |
11.1 |
114 |
1000 |
3x2x0.75 |
0.6 |
1.0 |
11.9 |
149 |
1000 |
4x2x0.75 |
0.6 |
1.1 |
13.2 |
192 |
1000 |
5x2x0.75 |
0.6 |
1.1 |
14.4 |
230 |
1000 |
6x2x0.75 |
0.6 |
1.2 |
16.0 |
275 |
1000 |
7x2x0.75 |
0.6 |
1.2 |
16.0 |
307 |
1000 |
10x2x0.75 |
0.6 |
1.3 |
20.6 |
435 |
1000 |
12x2x0.75 |
0.6 |
1.3 |
21.3 |
503 |
1000 |
16x2x0.75 |
0.6 |
1.4 |
23.9 |
655 |
1000 |
20x2x0.75 |
0.6 |
1.5 |
26.9 |
810 |
500 |
24x2x0.75 |
0.6 |
1.6 |
30.1 |
970 |
500 |
30x2x0.75 |
0.6 |
1.6 |
31.9 |
1176 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||
1x2x1 |
0.6 |
0.9 |
7.4 |
70 |
1000 |
2x2x1 |
0.6 |
1.0 |
11.8 |
129 |
1000 |
3x2x1 |
0.6 |
1.0 |
12.5 |
171 |
1000 |
4x2x1 |
0.6 |
1.1 |
14.0 |
220 |
1000 |
5x2x1 |
0.6 |
1.1 |
15.3 |
265 |
1000 |
6x2x1 |
0.6 |
1.2 |
16.9 |
317 |
1000 |
7x2x1 |
0.6 |
1.2 |
16.9 |
355 |
1000 |
10x2x1 |
0.6 |
1.3 |
21.9 |
503 |
1000 |
12x2x1 |
0.6 |
1.4 |
22.8 |
593 |
1000 |
16x2x1 |
0.6 |
1.4 |
25.4 |
763 |
500 |
20x2x1 |
0.6 |
1.5 |
28.6 |
945 |
500 |
24x2x1 |
0.6 |
1.6 |
32.0 |
1132 |
500 |
30x2x1 |
0.6 |
1.7 |
34.1 |
1389 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||
1x2x1.5 |
0.6 |
0.9 |
8.0 |
85 |
1000 |
2x2x1.5 |
0.6 |
1.1 |
13.0 |
164 |
1000 |
3x2x1.5 |
0.6 |
1.1 |
13.9 |
219 |
1000 |
4x2x1.5 |
0.6 |
1.1 |
15.3 |
277 |
1000 |
5x2x1.5 |
0.6 |
1.2 |
16.9 |
341 |
1000 |
6x2x1.5 |
0.6 |
1.2 |
18.5 |
400 |
1000 |
7x2x1.5 |
0.6 |
1.2 |
18.5 |
451 |
1000 |
10x2x1.5 |
0.6 |
1.4 |
24.2 |
650 |
1000 |
12x2x1.5 |
0.6 |
1.4 |
25.1 |
757 |
500 |
16x2x1.5 |
0.6 |
1.5 |
28.1 |
988 |
500 |
20x2x1.5 |
0.6 |
1.6 |
31.6 |
1225 |
500 |
24x2x1.5 |
0.6 |
1.8 |
35.6 |
1480 |
500 |
30x2x1.5 |
0.6 |
1.8 |
37.7 |
1802 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||
1x2x2.5 |
0.7 |
1.0 |
9.5 |
118 |
1000 |
2x2x2.5 |
0.7 |
1.1 |
15.3 |
224 |
1000 |
3x2x2.5 |
0.7 |
1.2 |
16.5 |
311 |
1000 |
4x2x2.5 |
0.7 |
1.2 |
18.1 |
395 |
1000 |
5x2x2.5 |
0.7 |
1.3 |
20.1 |
487 |
1000 |
6x2x2.5 |
0.7 |
1.4 |
22.2 |
582 |
1000 |
7x2x2.5 |
0.7 |
1.4 |
22.2 |
657 |
1000 |
10x2x2.5 |
0.7 |
1.6 |
29.0 |
943 |
500 |
12x2x2.5 |
0.7 |
1.6 |
30.0 |
1101 |
500 |
16x2x2.5 |
0.7 |
1.7 |
33.7 |
1438 |
500 |
20x2x2.5 |
0.7 |
1.9 |
38.1 |
1797 |
500 |
24x2x2.5 |
0.7 |
2.0 |
42.6 |
2148 |
500 |
30x2x2.5 |
0.7 |
2.1 |
45.4 |
2639 |
500 |

|