TiMF
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
40.4 |
26 |
19.2 |
12.8 |
7.86 |
Ohm/kM |
Insulation resistance |
min. |
1000 |
MOhm x km |
||||
Mutual capacitance |
max. |
150 |
nF/km |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 5 minutes |
1.5 kV A.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
300 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.30 mm) |
|||||||
1x3x0.5 |
0.4 |
0.2 |
7.4 |
1.1 |
10.5 |
170 |
1000 |
2x3x0.5 |
0.4 |
0.3 |
11.8 |
1.3 |
15.8 |
323 |
1000 |
3x3x0.5 |
0.4 |
0.3 |
12.6 |
1.3 |
16.5 |
374 |
1000 |
4x3x0.5 |
0.4 |
0.3 |
13.8 |
1.3 |
17.8 |
445 |
1000 |
5x3x0.5 |
0.4 |
0.3 |
15.1 |
1.4 |
19.3 |
506 |
1000 |
6x3x0.5 |
0.4 |
0.3 |
16.6 |
1.4 |
20.7 |
584 |
1000 |
7x3x0.5 |
0.4 |
0.3 |
16.6 |
1.4 |
20.7 |
625 |
1000 |
10x3x0.5 |
0.4 |
0.3 |
21.3 |
1.6 |
25.9 |
850 |
500 |
12x3x0.5 |
0.4 |
0.3 |
22.1 |
1.6 |
26.6 |
962 |
500 |
16x3x0.5 |
0.4 |
0.3 |
24.7 |
1.7 |
29.4 |
1174 |
500 |
20x3x0.5 |
0.4 |
0.3 |
27.7 |
1.8 |
32.6 |
1415 |
500 |
24x3x0.5 |
0.4 |
0.3 |
30.8 |
1.9 |
36.0 |
1663 |
500 |
30x3x0.5 |
0.4 |
0.4 |
33.2 |
2.0 |
39.0 |
2086 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||||
1x3x0.75 |
0.5 |
0.2 |
8.2 |
1.1 |
11.3 |
191 |
1000 |
2x3x0.75 |
0.5 |
0.3 |
13.5 |
1.3 |
17.4 |
367 |
1000 |
3x3x0.75 |
0.5 |
0.3 |
14.4 |
1.4 |
18.5 |
455 |
1000 |
4x3x0.75 |
0.5 |
0.3 |
15.8 |
1.4 |
20.0 |
540 |
1000 |
5x3x0.75 |
0.5 |
0.3 |
17.4 |
1.5 |
21.7 |
621 |
1000 |
6x3x0.75 |
0.5 |
0.3 |
19.1 |
1.5 |
23.4 |
715 |
1000 |
7x3x0.75 |
0.5 |
0.3 |
19.1 |
1.5 |
23.4 |
768 |
1000 |
10x3x0.75 |
0.5 |
0.3 |
24.7 |
1.7 |
29.4 |
1043 |
500 |
12x3x0.75 |
0.5 |
0.3 |
25.5 |
1.8 |
30.5 |
1196 |
500 |
16x3x0.75 |
0.5 |
0.3 |
28.6 |
1.9 |
33.7 |
1465 |
500 |
20x3x0.75 |
0.5 |
0.4 |
32.5 |
2.0 |
38.3 |
1896 |
500 |
24x3x0.75 |
0.5 |
0.4 |
36.2 |
2.2 |
42.4 |
2248 |
500 |
30x3x0.75 |
0.5 |
0.4 |
38.5 |
2.2 |
44.7 |
2605 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||||
1x3x1 |
0.5 |
0.2 |
8.6 |
1.2 |
11.9 |
204 |
1000 |
2x3x1 |
0.5 |
0.3 |
14.2 |
1.4 |
18.4 |
401 |
1000 |
3x3x1 |
0.5 |
0.3 |
15.2 |
1.4 |
19.3 |
463 |
1000 |
4x3x1 |
0.5 |
0.3 |
16.7 |
1.4 |
20.9 |
558 |
1000 |
5x3x1 |
0.5 |
0.3 |
18.4 |
1.5 |
22.7 |
644 |
1000 |
6x3x1 |
0.5 |
0.3 |
20.2 |
1.6 |
24.7 |
754 |
500 |
7x3x1 |
0.5 |
0.3 |
20.2 |
1.6 |
24.7 |
810 |
500 |
10x3x1 |
0.5 |
0.3 |
26.1 |
1.8 |
31.1 |
1126 |
500 |
12x3x1 |
0.5 |
0.3 |
27.1 |
1.8 |
32.0 |
1251 |
500 |
16x3x1 |
0.5 |
0.3 |
30.3 |
1.9 |
35.4 |
1559 |
500 |
20x3x1 |
0.5 |
0.4 |
34.4 |
2.1 |
40.4 |
2007 |
500 |
24x3x1 |
0.5 |
0.4 |
38.4 |
2.2 |
44.6 |
2361 |
500 |
30x3x1 |
0.5 |
0.4 |
40.9 |
2.3 |
47.3 |
2763 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||||
1x3x1.5 |
0.6 |
0.2 |
9.7 |
1.2 |
13.0 |
237 |
1000 |
2x3x1.5 |
0.6 |
0.3 |
16.2 |
1.4 |
20.4 |
482 |
1000 |
3x3x1.5 |
0.6 |
0.3 |
17.3 |
1.5 |
21.7 |
582 |
1000 |
4x3x1.5 |
0.6 |
0.3 |
19.2 |
1.5 |
23.5 |
701 |
1000 |
5x3x1.5 |
0.6 |
0.3 |
21.1 |
1.6 |
25.7 |
814 |
500 |
6x3x1.5 |
0.6 |
0.3 |
23.2 |
1.7 |
27.9 |
952 |
500 |
7x3x1.5 |
0.6 |
0.3 |
23.2 |
1.7 |
27.9 |
1028 |
500 |
10x3x1.5 |
0.6 |
0.3 |
30.2 |
1.9 |
35.3 |
1429 |
500 |
12x3x1.5 |
0.6 |
0.4 |
31.7 |
2.0 |
37.5 |
1744 |
500 |
16x3x1.5 |
0.6 |
0.4 |
35.4 |
2.1 |
41.4 |
2133 |
500 |
20x3x1.5 |
0.6 |
0.4 |
39.8 |
2.3 |
46.2 |
2599 |
500 |
24x3x1.5 |
0.6 |
0.4 |
44.9 |
2.5 |
51.7 |
3128 |
250 |
30x3x1.5 |
0.6 |
0.4 |
47.8 |
2.6 |
54.8 |
3694 |
250 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||||
1x3x2.5 |
0.6 |
0.3 |
10.6 |
1.3 |
14.6 |
318 |
1000 |
2x3x2.5 |
0.6 |
0.3 |
17.9 |
1.5 |
22.3 |
580 |
1000 |
3x3x2.5 |
0.6 |
0.3 |
19.2 |
1.6 |
23.7 |
736 |
1000 |
4x3x2.5 |
0.6 |
0.3 |
21.2 |
1.6 |
25.8 |
871 |
500 |
5x3x2.5 |
0.6 |
0.3 |
23.4 |
1.7 |
28.2 |
1043 |
500 |
6x3x2.5 |
0.6 |
0.3 |
25.8 |
1.8 |
30.7 |
1219 |
500 |
7x3x2.5 |
0.6 |
0.3 |
25.8 |
1.8 |
30.7 |
1328 |
500 |
10x3x2.5 |
0.6 |
0.4 |
34.0 |
2.1 |
40.0 |
1975 |
500 |
12x3x2.5 |
0.6 |
0.4 |
35.2 |
2.1 |
41.2 |
2215 |
500 |
16x3x2.5 |
0.6 |
0.4 |
39.5 |
2.3 |
45.9 |
2807 |
500 |
20x3x2.5 |
0.6 |
0.4 |
44.8 |
2.5 |
51.6 |
3471 |
250 |
24x3x2.5 |
0.6 |
0.4 |
50.0 |
2.7 |
57.2 |
4092 |
250 |
30x3x2.5 |
0.6 |
0.4 |
53.2 |
2.8 |
60.6 |
7685 |
250 |

|