TiMF
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
40.4 |
26 |
19.2 |
12.8 |
7.86 |
Ohm/kM |
Insulation resistance |
min. |
1000 |
MOhm x km |
||||
Mutual capacitance |
max. |
150 |
nF/km |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 5 minutes |
1.5 kV A.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
300 |
V |
IEC 60092-376 150/250 V (300 V)
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.3 mm) |
|||||
1x3x0.5 |
0.4 |
1.0 |
6.3 |
74 |
1000 |
2x3x0.5 |
0.4 |
1.1 |
10.1 |
131 |
1000 |
3x3x0.5 |
0.4 |
1.1 |
10.7 |
169 |
1000 |
4x3x0.5 |
0.4 |
1.2 |
11.9 |
215 |
1000 |
5x3x0.5 |
0.4 |
1.2 |
12.9 |
256 |
1000 |
6x3x0.5 |
0.4 |
1.3 |
14.2 |
304 |
1000 |
7x3x0.5 |
0.4 |
1.3 |
14.2 |
339 |
1000 |
10x3x0.5 |
0.4 |
1.4 |
18.2 |
476 |
1000 |
12x3x0.5 |
0.4 |
1.4 |
18.8 |
549 |
1000 |
16x3x0.5 |
0.4 |
1.5 |
21.1 |
712 |
1000 |
20x3x0.5 |
0.4 |
1.6 |
23.7 |
879 |
1000 |
24x3x0.5 |
0.4 |
1.7 |
26.4 |
1050 |
500 |
30x3x0.5 |
0.4 |
1.7 |
28.0 |
1271 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||
1x3x0.75 |
0.5 |
1.0 |
7.2 |
89 |
1000 |
2x3x0.75 |
0.5 |
1.2 |
11.9 |
167 |
1000 |
3x3x0.75 |
0.5 |
1.2 |
12.7 |
217 |
1000 |
4x3x0.75 |
0.5 |
1.2 |
13.9 |
270 |
1000 |
5x3x0.75 |
0.5 |
1.3 |
15.4 |
330 |
1000 |
6x3x0.75 |
0.5 |
1.4 |
16.9 |
392 |
1000 |
7x3x0.75 |
0.5 |
1.4 |
16.9 |
437 |
1000 |
10x3x0.75 |
0.5 |
1.5 |
21.8 |
616 |
1000 |
12x3x0.75 |
0.5 |
1.6 |
22.7 |
722 |
1000 |
16x3x0.75 |
0.5 |
1.7 |
25.4 |
935 |
500 |
20x3x0.75 |
0.5 |
1.8 |
28.5 |
1153 |
500 |
24x3x0.75 |
0.5 |
1.9 |
31.8 |
1377 |
500 |
30x3x0.75 |
0.5 |
2.0 |
33.9 |
1682 |
500 |
IEC 60092-376 150/250 V (300 V)
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||
1x3x1 |
0.5 |
1.0 |
7.6 |
88 |
1000 |
2x3x1 |
0.5 |
1.2 |
12.7 |
172 |
1000 |
3x3x1 |
0.5 |
1.2 |
13.5 |
225 |
1000 |
4x3x1 |
0.5 |
1.3 |
14.9 |
288 |
1000 |
5x3x1 |
0.5 |
1.3 |
16.3 |
345 |
1000 |
6x3x1 |
0.5 |
1.4 |
18.0 |
412 |
1000 |
7x3x1 |
0.5 |
1.4 |
18.0 |
460 |
1000 |
10x3x1 |
0.5 |
1.6 |
23.4 |
661 |
1000 |
12x3x1 |
0.5 |
1.6 |
24.2 |
763 |
1000 |
16x3x1 |
0.5 |
1.7 |
27.1 |
990 |
500 |
20x3x1 |
0.5 |
1.8 |
30.4 |
1223 |
500 |
24x3x1 |
0.5 |
1.9 |
34.0 |
1461 |
500 |
30x3x1 |
0.5 |
2.0 |
36.2 |
1786 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||
1x3x1.5 |
0.6 |
1.1 |
8.9 |
118 |
1000 |
2x3x1.5 |
0.6 |
1.3 |
14.9 |
231 |
1000 |
3x3x1.5 |
0.6 |
1.3 |
15.8 |
305 |
1000 |
4x3x1.5 |
0.6 |
1.4 |
17.6 |
391 |
1000 |
5x3x1.5 |
0.6 |
1.4 |
19.3 |
471 |
1000 |
6x3x1.5 |
0.6 |
1.5 |
21.3 |
561 |
1000 |
7x3x1.5 |
0.6 |
1.5 |
21.3 |
629 |
1000 |
10x3x1.5 |
0.6 |
1.7 |
27.7 |
903 |
500 |
12x3x1.5 |
0.6 |
1.8 |
28.8 |
1060 |
500 |
16x3x1.5 |
0.6 |
1.9 |
32.3 |
1375 |
500 |
20x3x1.5 |
0.6 |
2.0 |
36.3 |
1699 |
500 |
24x3x1.5 |
0.6 |
2.2 |
40.7 |
2047 |
500 |
30x3x1.5 |
0.6 |
2.3 |
43.3 |
2502 |
500 |
IEC 60092-376 150/250 V (300 V)
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||
1x3x2.5 |
0.6 |
1.1 |
9.8 |
157 |
1000 |
2x3x2.5 |
0.6 |
1.3 |
16.6 |
308 |
1000 |
3x3x2.5 |
0.6 |
1.4 |
17.9 |
423 |
1000 |
4x3x2.5 |
0.6 |
1.4 |
19.7 |
535 |
1000 |
5x3x2.5 |
0.6 |
1.5 |
21.8 |
658 |
1000 |
6x3x2.5 |
0.6 |
1.6 |
24.0 |
785 |
1000 |
7x3x2.5 |
0.6 |
1.6 |
24.0 |
884 |
1000 |
10x3x2.5 |
0.6 |
1.9 |
31.5 |
1281 |
500 |
12x3x2.5 |
0.6 |
1.9 |
32.6 |
1491 |
500 |
16x3x2.5 |
0.6 |
2.0 |
36.5 |
1941 |
500 |
20x3x2.5 |
0.6 |
2.2 |
41.2 |
2420 |
500 |
24x3x2.5 |
0.6 |
2.4 |
46.2 |
2911 |
500 |
30x3x2.5 |
0.6 |
2.5 |
49.2 |
3565 |
500 |

|