PiMF
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
40.4 |
26 |
19.2 |
12.8 |
7.86 |
Ohm/kM |
Insulation resistance |
min. |
1000 |
MOhm x km |
||||
Mutual capacitance |
max. |
150 |
nF/km |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 5 minutes |
1.5 kV A.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
300 |
V |
IEC 60092-376 150/250 V (300 V)
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.3 mm) |
|||||
1x2x0.5 |
0.4 |
1.0 |
6.0 |
66 |
1000 |
2x2x0.5 |
0.4 |
1.1 |
9.2 |
113 |
1000 |
3x2x0.5 |
0.4 |
1.1 |
9.7 |
145 |
1000 |
4x2x0.5 |
0.4 |
1.1 |
10.6 |
178 |
1000 |
5x2x0.5 |
0.4 |
1.2 |
11.7 |
216 |
1000 |
6x2x0.5 |
0.4 |
1.2 |
12.7 |
251 |
1000 |
7x2x0.5 |
0.4 |
1.2 |
12.7 |
279 |
1000 |
10x2x0.5 |
0.4 |
1.3 |
16.3 |
391 |
1000 |
12x2x0.5 |
0.4 |
1.4 |
17.0 |
458 |
1000 |
16x2x0.5 |
0.4 |
1.4 |
18.8 |
584 |
1000 |
20x2x0.5 |
0.4 |
1.5 |
21.1 |
720 |
1000 |
24x2x0.5 |
0.4 |
1.6 |
23.5 |
860 |
1000 |
30x2x0.5 |
0.4 |
1.6 |
24.9 |
1040 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||
1x2x0.75 |
0.5 |
1.0 |
6.9 |
78 |
1000 |
2x2x0.75 |
0.5 |
1.1 |
10.6 |
136 |
1000 |
3x2x0.75 |
0.5 |
1.2 |
11.5 |
181 |
1000 |
4x2x0.75 |
0.5 |
1.2 |
12.5 |
222 |
1000 |
5x2x0.75 |
0.5 |
1.2 |
13.7 |
265 |
1000 |
6x2x0.75 |
0.5 |
1.3 |
15.1 |
314 |
1000 |
7x2x0.75 |
0.5 |
1.3 |
15.1 |
350 |
1000 |
10x2x0.75 |
0.5 |
1.4 |
19.4 |
492 |
1000 |
12x2x0.75 |
0.5 |
1.5 |
20.2 |
576 |
1000 |
16x2x0.75 |
0.5 |
1.6 |
22.6 |
745 |
1000 |
20x2x0.75 |
0.5 |
1.7 |
25.4 |
918 |
500 |
24x2x0.75 |
0.5 |
1.8 |
28.3 |
1096 |
500 |
30x2x0.75 |
0.5 |
1.8 |
30.0 |
1323 |
500 |
IEC 60092-376 150/250 V (300 V)
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||
1x2x1 |
0.5 |
1.0 |
7.2 |
74 |
1000 |
2x2x1 |
0.5 |
1.1 |
11.3 |
134 |
1000 |
3x2x1 |
0.5 |
1.2 |
12.2 |
179 |
1000 |
4x2x1 |
0.5 |
1.2 |
13.3 |
222 |
1000 |
5x2x1 |
0.5 |
1.3 |
14.7 |
271 |
1000 |
6x2x1 |
0.5 |
1.3 |
16.1 |
316 |
1000 |
7x2x1 |
0.5 |
1.3 |
16.1 |
351 |
1000 |
10x2x1 |
0.5 |
1.5 |
20.9 |
505 |
1000 |
12x2x1 |
0.5 |
1.5 |
21.6 |
582 |
1000 |
16x2x1 |
0.5 |
1.6 |
24.1 |
753 |
1000 |
20x2x1 |
0.5 |
1.7 |
27.1 |
929 |
500 |
24x2x1 |
0.5 |
1.8 |
30.2 |
1110 |
500 |
30x2x1 |
0.5 |
1.9 |
32.2 |
1354 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||
1x2x1.5 |
0.6 |
1.0 |
8.2 |
92 |
1000 |
2x2x1.5 |
0.6 |
1.2 |
13.2 |
177 |
1000 |
3x2x1.5 |
0.6 |
1.3 |
14.3 |
238 |
1000 |
4x2x1.5 |
0.6 |
1.3 |
15.7 |
295 |
1000 |
5x2x1.5 |
0.6 |
1.4 |
17.3 |
362 |
1000 |
6x2x1.5 |
0.6 |
1.4 |
18.9 |
422 |
1000 |
7x2x1.5 |
0.6 |
1.4 |
18.9 |
471 |
1000 |
10x2x1.5 |
0.6 |
1.6 |
24.6 |
677 |
500 |
12x2x1.5 |
0.6 |
1.6 |
25.5 |
782 |
500 |
16x2x1.5 |
0.6 |
1.8 |
28.7 |
1026 |
500 |
20x2x1.5 |
0.6 |
1.9 |
32.2 |
1266 |
500 |
24x2x1.5 |
0.6 |
2.0 |
36.0 |
1511 |
500 |
30x2x1.5 |
0.6 |
2.1 |
38.3 |
1843 |
500 |
IEC 60092-376 150/250 V (300 V)
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||
1x2x2.5 |
0.6 |
1.1 |
9.3 |
126 |
1000 |
2x2x2.5 |
0.6 |
1.3 |
14.9 |
240 |
1000 |
3x2x2.5 |
0.6 |
1.3 |
15.9 |
317 |
1000 |
4x2x2.5 |
0.6 |
1.4 |
17.7 |
407 |
1000 |
5x2x2.5 |
0.6 |
1.4 |
19.4 |
490 |
1000 |
6x2x2.5 |
0.6 |
1.5 |
21.4 |
583 |
1000 |
7x2x2.5 |
0.6 |
1.5 |
21.4 |
654 |
1000 |
10x2x2.5 |
0.6 |
1.7 |
27.8 |
938 |
500 |
12x2x2.5 |
0.6 |
1.8 |
29.0 |
1102 |
500 |
16x2x2.5 |
0.6 |
1.9 |
32.4 |
1430 |
500 |
20x2x2.5 |
0.6 |
2.0 |
36.4 |
1767 |
500 |
24x2x2.5 |
0.6 |
2.2 |
40.9 |
2128 |
500 |
30x2x2.5 |
0.6 |
2.3 |
43.5 |
2601 |
500 |

|