نمایش منو

NA2XSY

3.6/6 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diamater

Insulation thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

Kg/Km

meter

1x25rm/16

5.8

2.5

1.8

20.5

503

1000

1x35rm/16

7.0

2.5

1.8

21.7

556

1000

1x50rm/16

8.2

2.5

1.8

22.9

630

1000

1x70rm/16

9.9

2.5

1.8

24.6

718

1000

1x95rm/16

11.5

2.5

1.7

26.0

797

1000

1x120rm/16

13.0

2.5

1.8

27.7

907

1000

1x150rm/25

14.5

2.5

1.8

29.2

1113

1000

1x185rm/25

16.1

2.5

1.9

31.4

1265

1000

1x240rm/25

18.5

2.6

2.0

34.2

1498

500

1x300rm/25

20.6

2.8

2.1

37.3

1767

500

1x400rm/35

23.2

3.0

2.2

41.2

2221

500

1x500rm/35

26.3

3.2

2.3

44.9

2626

500

6/10 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diamater

Insulation thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

Kg/Km

meter

1x25rm/16

5.8

3.4

1.8

22.3

558

1000

1x35rm/16

7.0

3.4

1.8

23.5

614

1000

1x50rm/16

8.2

3.4

1.7

24.5

680

1000

1x70rm/16

9.9

3.4

1.8

26.4

785

1000

1x95rm/16

11.5

3.4

1.8

28.0

879

1000

1x120rm/16

13.0

3.4

1.9

29.7

994

1000

1x150rm/25

14.5

3.4

1.9

31.2

1205

1000

1x185rm/25

16.1

3.4

2.0

33.4

1364

1000

1x240rm/25

18.5

3.4

2.0

35.8

1579

500

1x300rm/25

20.6

3.4

2.1

38.5

1834

500

1x400rm/35

23.2

3.4

2.2

42.0

2285

500

1x500rm/35

26.3

3.4

2.3

45.3

2652

500

8.7/15 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diamater

Insulation thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

Kg/Km

meter

1x25rm/16

5.8

4.5

1.8

24.5

632

1000

1x35rm/16

7.0

4.5

1.8

25.7

692

1000

1x50rm/16

8.2

4.5

1.8

26.9

763

1000

1x70rm/16

9.9

4.5

1.8

28.6

863

1000

1x95rm/16

11.5

4.5

1.9

30.4

986

1000

1x120rm/16

13.0

4.5

1.9

31.9

1103

1000

1x150rm/25

14.5

4.5

2.0

33.6

1323

1000

1x185rm/25

16.1

4.5

2.0

35.6

1484

1000

1x240rm/25

18.5

4.5

2.1

38.2

1715

500

1x300rm/25

20.6

4.5

2.2

40.9

1340

500

1x400rm/35

23.2

4.5

2.3

44.4

2442

500

1x500rm/35

25.8

4.5

2.4

46.5

2790

500

12/20 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diamater

Insulation thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

Kg/Km

meter

1x25rm/16

5.8

5.5

1.8

26.5

707

1000

1x35rm/16

7.0

5.5

1.8

27.7

773

1000

1x50rm/16

8.2

5.5

1.9

29.1

858

1000

1x70rm/16

9.9

5.5

1.9

30.8

962

1000

1x95rm/16

11.5

5.5

2.0

32.6

1101

1000

1x120rm/16

13.0

5.5

2.0

34.1

1204

1000

1x150rm/25

14.5

5.5

2.1

35.8

1440

1000

1x185rm/25

16.1

5.5

2.1

37.8

1599

1000

1x240rm/25

18.5

5.5

2.2

40.4

1849

500

1x300rm/25

20.6

5.5

2.3

43.1

2113

500

1x400rm/35

23.2

5.5

2.4

46.6

2595

500

1x500rm/35

26.3

5.5

2.5

49.9

2986

500

18/30 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diamater

Insulation thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

Kg/Km

meter

1x50rm/16

8.2

8.0

2.0

34.3

1112

500

1x70rm/16

9.9

8.0

2.1

36.2

1246

500

1x95rm/16

11.5

8.0

2.1

37.8

1374

500

1x120rm/16

13.0

8.0

2.2

39.5

1516

500

1x150rm/25

14.5

8.0

2.2

41.0

1739

500

1x185rm/25

16.1

8.0

2.3

43.2

1934

1000

1x240rm/25

18.5

8.0

2.4

45.8

2205

500

1x300rm/25

20.6

8.0

2.5

48.5

2480

500