Multi-Triple
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
36.7 |
25.0 |
18.5 |
12.3 |
7.4 |
Ohm/kM |
Insulation resistance |
min. |
1000 |
MOhm x km |
||||
Mutual capacitance |
max. |
150 |
nF/km |
||||
Capacitance unbalance |
max. |
500 |
pF/500m |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 1 minute |
2.0 kV A.C or 3.0 kV D.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
500 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.30 mm) |
|||||||
1x3x0.5 |
0.6 |
0.9 |
11.9 |
1.4 |
16.5 |
446 |
1000 |
2x3x0.5 |
0.6 |
0.9 |
15.3 |
1.5 |
20.1 |
596 |
1000 |
3x3x0.5 |
0.6 |
1.25 |
15.9 |
1.5 |
21.4 |
762 |
1000 |
4x3x0.5 |
0.6 |
1.25 |
16.9 |
1.5 |
22.4 |
834 |
1000 |
5x3x0.5 |
0.6 |
1.25 |
18.0 |
1.6 |
23.7 |
907 |
1000 |
6x3x0.5 |
0.6 |
1.25 |
19.2 |
1.6 |
24.9 |
983 |
500 |
7x3x0.5 |
0.6 |
1.25 |
19.2 |
1.6 |
24.9 |
1005 |
500 |
10x3x0.5 |
0.6 |
1.6 |
23.1 |
1.7 |
29.7 |
1443 |
500 |
12x3x0.5 |
0.6 |
1.6 |
23.7 |
1.7 |
30.3 |
1516 |
500 |
16x3x0.5 |
0.6 |
1.6 |
25.8 |
1.8 |
32.6 |
1727 |
500 |
20x3x0.5 |
0.6 |
2 |
28.3 |
1.8 |
35.9 |
2194 |
500 |
24x3x0.5 |
0.6 |
2 |
30.9 |
1.9 |
38.7 |
2455 |
500 |
30x3x0.5 |
0.6 |
2 |
32.6 |
1.9 |
40.4 |
2674 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||||
1x3x0.75 |
0.6 |
0.9 |
12.4 |
1.4 |
17.0 |
474 |
1000 |
2x3x0.75 |
0.6 |
1.25 |
16.0 |
1.5 |
21.5 |
771 |
1000 |
3x3x0.75 |
0.6 |
1.25 |
16.7 |
1.5 |
22.2 |
825 |
1000 |
4x3x0.75 |
0.6 |
1.25 |
17.9 |
1.6 |
23.6 |
917 |
1000 |
5x3x0.75 |
0.6 |
1.25 |
19.1 |
1.6 |
24.8 |
1002 |
500 |
6x3x0.75 |
0.6 |
1.25 |
20.4 |
1.6 |
26.1 |
1089 |
500 |
7x3x0.75 |
0.6 |
1.25 |
20.4 |
1.6 |
26.1 |
1120 |
500 |
10x3x0.75 |
0.6 |
1.6 |
24.7 |
1.7 |
31.3 |
1595 |
500 |
12x3x0.75 |
0.6 |
1.6 |
25.4 |
1.8 |
32.2 |
1716 |
500 |
16x3x0.75 |
0.6 |
2 |
27.7 |
1.8 |
35.3 |
2205 |
500 |
20x3x0.75 |
0.6 |
2 |
30.4 |
1.9 |
38.2 |
2503 |
500 |
24x3x0.75 |
0.6 |
2 |
33.3 |
2.0 |
41.3 |
2806 |
500 |
30x3x0.75 |
0.6 |
2.5 |
35.5 |
2.0 |
44.5 |
3549 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||||
1x3x1 |
0.6 |
0.9 |
12.8 |
1.4 |
17.4 |
494 |
1000 |
2x3x1 |
0.6 |
1.25 |
16.7 |
1.5 |
22.2 |
809 |
1000 |
3x3x1 |
0.6 |
1.25 |
17.5 |
1.6 |
23.2 |
892 |
1000 |
4x3x1 |
0.6 |
1.25 |
18.7 |
1.6 |
24.4 |
985 |
1000 |
5x3x1 |
0.6 |
1.25 |
20.0 |
1.6 |
25.7 |
1081 |
500 |
6x3x1 |
0.6 |
1.25 |
21.4 |
1.6 |
27.1 |
1177 |
500 |
7x3x1 |
0.6 |
1.25 |
21.4 |
1.6 |
27.1 |
1217 |
500 |
10x3x1 |
0.6 |
1.6 |
26.0 |
1.8 |
32.8 |
1766 |
500 |
12x3x1 |
0.6 |
1.6 |
26.8 |
1.8 |
33.6 |
1876 |
500 |
16x3x1 |
0.6 |
2 |
29.3 |
1.9 |
37.1 |
2435 |
500 |
20x3x1 |
0.6 |
2 |
32.2 |
1.9 |
40.0 |
2757 |
500 |
24x3x1 |
0.6 |
2.5 |
35.7 |
2.0 |
44.7 |
3568 |
500 |
30x3x1 |
0.6 |
2.5 |
37.6 |
2.1 |
46.8 |
3945 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||||
1x3x1.5 |
0.6 |
0.9 |
13.4 |
1.4 |
18.0 |
535 |
1000 |
2x3x1.5 |
0.6 |
1.25 |
17.8 |
1.6 |
23.5 |
906 |
1000 |
3x3x1.5 |
0.6 |
1.25 |
18.7 |
1.6 |
24.4 |
999 |
1000 |
4x3x1.5 |
0.6 |
1.25 |
20.0 |
1.6 |
25.7 |
1112 |
500 |
5x3x1.5 |
0.6 |
1.25 |
21.5 |
1.7 |
27.4 |
1248 |
500 |
6x3x1.5 |
0.6 |
1.6 |
23.0 |
1.7 |
29.6 |
1541 |
500 |
7x3x1.5 |
0.6 |
1.6 |
23.0 |
1.7 |
29.6 |
1597 |
500 |
10x3x1.5 |
0.6 |
2 |
28.3 |
1.8 |
35.9 |
2311 |
500 |
12x3x1.5 |
0.6 |
2 |
29.1 |
1.9 |
36.9 |
2480 |
500 |
16x3x1.5 |
0.6 |
2 |
31.9 |
1.9 |
39.7 |
2867 |
500 |
20x3x1.5 |
0.6 |
2.5 |
35.6 |
2.0 |
44.6 |
3750 |
500 |
24x3x1.5 |
0.6 |
2.5 |
39.5 |
2.1 |
48.7 |
4298 |
500 |
30x3x1.5 |
0.6 |
2.5 |
41.6 |
2.2 |
51.0 |
4785 |
250 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||||
1x3x2.5 |
0.7 |
0.9 |
14.8 |
1.5 |
19.6 |
622 |
1000 |
2x3x2.5 |
0.7 |
1.25 |
20.2 |
1.6 |
25.9 |
1079 |
500 |
3x3x2.5 |
0.7 |
1.25 |
21.2 |
1.7 |
27.1 |
1218 |
500 |
4x3x2.5 |
0.7 |
1.6 |
22.8 |
1.7 |
29.4 |
1555 |
500 |
5x3x2.5 |
0.7 |
1.6 |
24.6 |
1.8 |
31.4 |
1741 |
500 |
6x3x2.5 |
0.7 |
1.6 |
26.5 |
1.8 |
33.3 |
1935 |
500 |
7x3x2.5 |
0.7 |
1.6 |
26.5 |
1.8 |
33.3 |
2023 |
500 |
10x3x2.5 |
0.7 |
2 |
33.3 |
2.0 |
41.3 |
2977 |
500 |
12x3x2.5 |
0.7 |
2 |
34.3 |
2.0 |
42.3 |
3227 |
500 |
16x3x2.5 |
0.7 |
2.5 |
38.2 |
2.1 |
47.4 |
4253 |
500 |
20x3x2.5 |
0.7 |
2.5 |
42.2 |
2.2 |
51.6 |
4921 |
250 |
24x3x2.5 |
0.7 |
3.15 |
46.8 |
2.4 |
57.9 |
6356 |
250 |
30x3x2.5 |
0.7 |
3.15 |
49.4 |
2.4 |
60.5 |
7078 |
250 |

|