Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
36.7 |
25.0 |
18.5 |
12.3 |
7.4 |
Ohm/kM |
Insulation resistance |
min. |
1000 |
MOhm x km |
||||
Mutual capacitance |
max. |
150 |
nF/km |
||||
Capacitance unbalance |
max. |
500 |
pF/500m |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 1 minute |
2.0 kV A.C or 3.0 kV D.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
500 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Armour Tape Thickness |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.30 mm) |
|||||||
1x2x0.5 |
0.6 |
0.2 |
7.8 |
1.3 |
11.2 |
180 |
1000 |
2x2x0.5 |
0.6 |
0.2 |
12.1 |
1.4 |
15.7 |
288 |
1000 |
3x2x0.5 |
0.6 |
0.2 |
12.9 |
1.4 |
16.5 |
329 |
1000 |
4x2x0.5 |
0.6 |
0.2 |
14.2 |
1.4 |
17.8 |
380 |
1000 |
5x2x0.5 |
0.6 |
0.2 |
15.5 |
1.5 |
19.3 |
439 |
1000 |
6x2x0.5 |
0.6 |
0.2 |
17.0 |
1.5 |
20.8 |
493 |
1000 |
7x2x0.5 |
0.6 |
0.2 |
17.0 |
1.5 |
20.8 |
521 |
1000 |
10x2x0.5 |
0.6 |
0.2 |
21.9 |
1.6 |
25.9 |
702 |
500 |
12x2x0.5 |
0.6 |
0.2 |
22.7 |
1.6 |
26.7 |
772 |
500 |
16x2x0.5 |
0.6 |
0.2 |
25.4 |
1.7 |
29.6 |
943 |
500 |
20x2x0.5 |
0.6 |
0.2 |
28.4 |
1.7 |
32.6 |
1112 |
500 |
24x2x0.5 |
0.6 |
0.2 |
31.7 |
1.8 |
36.1 |
1297 |
500 |
30x2x0.5 |
0.6 |
0.2 |
33.7 |
1.8 |
38.1 |
1503 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||||
1x2x0.75 |
0.6 |
0.2 |
8.2 |
1.3 |
11.6 |
194 |
1000 |
2x2x0.75 |
0.6 |
0.2 |
12.8 |
1.4 |
16.4 |
314 |
1000 |
3x2x0.75 |
0.6 |
0.2 |
13.7 |
1.4 |
17.3 |
364 |
1000 |
4x2x0.75 |
0.6 |
0.2 |
15.1 |
1.5 |
18.9 |
429 |
1000 |
5x2x0.75 |
0.6 |
0.2 |
16.5 |
1.5 |
20.3 |
490 |
1000 |
6x2x0.75 |
0.6 |
0.2 |
18.1 |
1.5 |
21.9 |
553 |
1000 |
7x2x0.75 |
0.6 |
0.2 |
18.1 |
1.5 |
21.9 |
587 |
1000 |
10x2x0.75 |
0.6 |
0.2 |
23.4 |
1.6 |
27.4 |
794 |
500 |
12x2x0.75 |
0.6 |
0.2 |
24.3 |
1.7 |
28.5 |
889 |
500 |
16x2x0.75 |
0.6 |
0.2 |
27.1 |
1.7 |
31.3 |
1079 |
500 |
20x2x0.75 |
0.6 |
0.2 |
30.4 |
1.8 |
34.8 |
1291 |
500 |
24x2x0.75 |
0.6 |
0.2 |
34.0 |
1.9 |
38.6 |
1509 |
500 |
30x2x0.75 |
0.6 |
0.2 |
36.5 |
1.9 |
41.1 |
1797 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Tape Thickness |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||||
1x2x1 |
0.6 |
0.2 |
8.6 |
1.3 |
12.0 |
206 |
1000 |
2x2x1 |
0.6 |
0.2 |
13.5 |
1.4 |
17.1 |
337 |
1000 |
3x2x1 |
0.6 |
0.2 |
14.4 |
1.4 |
18.0 |
393 |
1000 |
4x2x1 |
0.6 |
0.2 |
15.8 |
1.5 |
19.6 |
467 |
1000 |
5x2x1 |
0.6 |
0.2 |
17.4 |
1.5 |
21.2 |
535 |
1000 |
6x2x1 |
0.6 |
0.2 |
19.1 |
1.5 |
22.9 |
606 |
1000 |
7x2x1 |
0.6 |
0.2 |
19.1 |
1.5 |
22.9 |
646 |
1000 |
10x2x1 |
0.6 |
0.2 |
24.7 |
1.7 |
28.9 |
889 |
500 |
12x2x1 |
0.6 |
0.2 |
25.6 |
1.7 |
29.8 |
986 |
500 |
16x2x1 |
0.6 |
0.2 |
28.6 |
1.7 |
32.8 |
1204 |
500 |
20x2x1 |
0.6 |
0.2 |
32.1 |
1.8 |
36.5 |
1445 |
500 |
24x2x1 |
0.6 |
0.2 |
36.3 |
1.9 |
40.9 |
1732 |
500 |
30x2x1 |
0.6 |
0.2 |
38.6 |
1.9 |
43.2 |
2022 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||||
1x2x1.5 |
0.6 |
0.2 |
9.2 |
1.3 |
12.6 |
230 |
1000 |
2x2x1.5 |
0.6 |
0.2 |
14.6 |
1.5 |
18.4 |
389 |
1000 |
3x2x1.5 |
0.6 |
0.2 |
15.5 |
1.5 |
19.3 |
459 |
1000 |
4x2x1.5 |
0.6 |
0.2 |
17.1 |
1.5 |
20.9 |
540 |
1000 |
5x2x1.5 |
0.6 |
0.2 |
18.9 |
1.5 |
22.7 |
623 |
1000 |
6x2x1.5 |
0.6 |
0.2 |
20.7 |
1.6 |
24.7 |
718 |
500 |
7x2x1.5 |
0.6 |
0.2 |
20.7 |
1.6 |
24.7 |
771 |
500 |
10x2x1.5 |
0.6 |
0.2 |
26.8 |
1.7 |
31.0 |
1052 |
500 |
12x2x1.5 |
0.6 |
0.2 |
27.8 |
1.7 |
32.0 |
1176 |
500 |
16x2x1.5 |
0.6 |
0.2 |
31.1 |
1.8 |
35.5 |
1461 |
500 |
20x2x1.5 |
0.6 |
0.2 |
35.4 |
1.9 |
40.0 |
1798 |
500 |
24x2x1.5 |
0.6 |
0.5 |
39.5 |
2.0 |
45.5 |
2581 |
500 |
30x2x1.5 |
0.6 |
0.5 |
42.0 |
2.1 |
48.2 |
2995 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Tape Thickness |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||||
1x2x2.5 |
0.7 |
0.2 |
10.4 |
1.4 |
14.0 |
281 |
1000 |
2x2x2.5 |
0.7 |
0.2 |
16.8 |
1.5 |
20.6 |
477 |
1000 |
3x2x2.5 |
0.7 |
0.2 |
17.9 |
1.5 |
21.7 |
573 |
1000 |
4x2x2.5 |
0.7 |
0.2 |
19.8 |
1.6 |
23.8 |
692 |
1000 |
5x2x2.5 |
0.7 |
0.2 |
21.8 |
1.6 |
25.8 |
805 |
500 |
6x2x2.5 |
0.7 |
0.2 |
24.0 |
1.7 |
28.2 |
931 |
500 |
7x2x2.5 |
0.7 |
0.2 |
24.0 |
1.7 |
28.2 |
1006 |
500 |
10x2x2.5 |
0.7 |
0.2 |
31.2 |
1.8 |
35.6 |
1382 |
500 |
12x2x2.5 |
0.7 |
0.2 |
32.4 |
1.9 |
37.0 |
1570 |
500 |
16x2x2.5 |
0.7 |
0.2 |
36.7 |
2.0 |
41.5 |
2003 |
500 |
20x2x2.5 |
0.7 |
0.5 |
41.3 |
2.1 |
47.5 |
2912 |
500 |
24x2x2.5 |
0.7 |
0.5 |
46.1 |
2.2 |
52.5 |
3391 |
250 |
30x2x2.5 |
0.7 |
0.5 |
49.5 |
2.3 |
56.1 |
4019 |
250 |

|