Multi-Triple
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
36.7 |
25.0 |
18.5 |
12.3 |
7.4 |
Ohm/kM |
Insulation resistance |
min. |
1000 |
MOhm x km |
||||
Mutual capacitance |
max. |
150 |
nF/km |
||||
Capacitance unbalance |
max. |
500 |
pF/500m |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 1 minute |
2.0 kV A.C or 3.0 kV D.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
500 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.30 mm) |
|||||||
1x3x0.5 |
0.6 |
0.9 |
7.9 |
1.3 |
12.3 |
278 |
1000 |
2x3x0.5 |
0.6 |
0.9 |
11.9 |
1.4 |
16.5 |
420 |
1000 |
3x3x0.5 |
0.6 |
0.9 |
12.7 |
1.4 |
17.3 |
472 |
1000 |
4x3x0.5 |
0.6 |
0.9 |
14.0 |
1.5 |
18.8 |
542 |
1000 |
5x3x0.5 |
0.6 |
0.9 |
15.3 |
1.5 |
20.1 |
605 |
1000 |
6x3x0.5 |
0.6 |
1.25 |
16.7 |
1.5 |
22.2 |
801 |
1000 |
7x3x0.5 |
0.6 |
1.25 |
16.7 |
1.5 |
22.2 |
829 |
1000 |
10x3x0.5 |
0.6 |
1.25 |
21.6 |
1.6 |
27.3 |
1097 |
500 |
12x3x0.5 |
0.6 |
1.6 |
22.3 |
1.7 |
28.9 |
1362 |
500 |
16x3x0.5 |
0.6 |
1.6 |
24.9 |
1.7 |
31.5 |
1588 |
500 |
20x3x0.5 |
0.6 |
2 |
28.0 |
1.8 |
35.6 |
2084 |
500 |
24x3x0.5 |
0.6 |
2 |
31.2 |
1.9 |
39.0 |
2379 |
500 |
30x3x0.5 |
0.6 |
2 |
33.2 |
1.9 |
41.0 |
2652 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||||
1x3x0.75 |
0.6 |
0.9 |
8.3 |
1.3 |
12.7 |
297 |
1000 |
2x3x0.75 |
0.6 |
0.9 |
12.7 |
1.4 |
17.3 |
463 |
1000 |
3x3x0.75 |
0.6 |
0.9 |
13.5 |
1.5 |
18.3 |
526 |
1000 |
4x3x0.75 |
0.6 |
0.9 |
14.9 |
1.5 |
19.7 |
604 |
1000 |
5x3x0.75 |
0.6 |
1.25 |
16.4 |
1.5 |
21.9 |
815 |
1000 |
6x3x0.75 |
0.6 |
1.25 |
17.9 |
1.6 |
23.6 |
908 |
1000 |
7x3x0.75 |
0.6 |
1.25 |
17.9 |
1.6 |
23.6 |
946 |
1000 |
10x3x0.75 |
0.6 |
1.6 |
23.1 |
1.7 |
29.7 |
1439 |
500 |
12x3x0.75 |
0.6 |
1.6 |
24.0 |
1.7 |
30.6 |
1540 |
500 |
16x3x0.75 |
0.6 |
1.6 |
26.8 |
1.8 |
33.6 |
1818 |
500 |
20x3x0.75 |
0.6 |
2 |
30.1 |
1.9 |
37.9 |
2383 |
500 |
24x3x0.75 |
0.6 |
2 |
33.6 |
1.9 |
41.4 |
2705 |
500 |
30x3x0.75 |
0.6 |
2.5 |
36.1 |
2.0 |
45.1 |
3534 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||||
1x3x1 |
0.6 |
0.9 |
8.7 |
1.4 |
13.3 |
320 |
1000 |
2x3x1 |
0.6 |
0.9 |
13.4 |
1.4 |
18.0 |
497 |
1000 |
3x3x1 |
0.6 |
0.9 |
14.3 |
1.5 |
19.1 |
575 |
1000 |
4x3x1 |
0.6 |
1.25 |
15.7 |
1.5 |
21.2 |
785 |
1000 |
5x3x1 |
0.6 |
1.25 |
17.3 |
1.5 |
22.8 |
888 |
1000 |
6x3x1 |
0.6 |
1.25 |
18.9 |
1.6 |
24.6 |
1001 |
500 |
7x3x1 |
0.6 |
1.25 |
18.9 |
1.6 |
24.6 |
1048 |
500 |
10x3x1 |
0.6 |
1.6 |
24.5 |
1.7 |
31.1 |
1574 |
500 |
12x3x1 |
0.6 |
1.6 |
25.4 |
1.7 |
32.0 |
1710 |
500 |
16x3x1 |
0.6 |
2 |
28.4 |
1.8 |
36.0 |
2287 |
500 |
20x3x1 |
0.6 |
2 |
31.9 |
1.9 |
39.7 |
2657 |
500 |
24x3x1 |
0.6 |
2.5 |
35.6 |
2.0 |
44.6 |
3439 |
500 |
30x3x1 |
0.6 |
2.5 |
38.3 |
2.1 |
47.5 |
3924 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||||
1x3x1.5 |
0.6 |
0.9 |
9.4 |
1.4 |
14.0 |
361 |
1000 |
2x3x1.5 |
0.6 |
0.9 |
14.5 |
1.5 |
19.3 |
573 |
1000 |
3x3x1.5 |
0.6 |
0.9 |
15.5 |
1.5 |
20.3 |
663 |
1000 |
4x3x1.5 |
0.6 |
1.25 |
17.1 |
1.6 |
22.8 |
909 |
1000 |
5x3x1.5 |
0.6 |
1.25 |
18.8 |
1.6 |
24.5 |
1032 |
1000 |
6x3x1.5 |
0.6 |
1.25 |
20.6 |
1.6 |
26.3 |
1166 |
500 |
7x3x1.5 |
0.6 |
1.25 |
20.6 |
1.6 |
26.3 |
1230 |
500 |
10x3x1.5 |
0.6 |
1.6 |
26.7 |
1.8 |
33.5 |
1855 |
500 |
12x3x1.5 |
0.6 |
2 |
27.7 |
1.8 |
35.3 |
2279 |
500 |
16x3x1.5 |
0.6 |
2 |
31.0 |
1.9 |
38.8 |
2717 |
500 |
20x3x1.5 |
0.6 |
2.5 |
35.3 |
2.0 |
44.3 |
3633 |
500 |
24x3x1.5 |
0.6 |
2.5 |
39.3 |
2.1 |
48.5 |
4123 |
500 |
30x3x1.5 |
0.6 |
2.5 |
41.9 |
2.2 |
51.3 |
4681 |
250 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||||
1x3x2.5 |
0.7 |
0.9 |
10.7 |
1.4 |
15.3 |
429 |
1000 |
2x3x2.5 |
0.7 |
1.25 |
16.8 |
1.6 |
22.5 |
847 |
1000 |
3x3x2.5 |
0.7 |
1.25 |
18.0 |
1.6 |
23.7 |
977 |
1000 |
4x3x2.5 |
0.7 |
1.25 |
19.9 |
1.6 |
25.6 |
1145 |
500 |
5x3x2.5 |
0.7 |
1.6 |
21.9 |
1.7 |
28.5 |
1488 |
500 |
6x3x2.5 |
0.7 |
1.6 |
24.1 |
1.7 |
30.7 |
1676 |
500 |
7x3x2.5 |
0.7 |
1.6 |
24.1 |
1.7 |
30.7 |
1772 |
500 |
10x3x2.5 |
0.7 |
2 |
31.4 |
1.9 |
39.2 |
2672 |
500 |
12x3x2.5 |
0.7 |
2 |
32.5 |
1.9 |
40.3 |
2932 |
500 |
16x3x2.5 |
0.7 |
2.5 |
36.8 |
2.1 |
46.0 |
3989 |
500 |
20x3x2.5 |
0.7 |
2.5 |
41.4 |
2.2 |
50.8 |
4702 |
250 |
24x3x2.5 |
0.7 |
3.15 |
46.3 |
2.3 |
57.2 |
6046 |
250 |
30x3x2.5 |
0.7 |
3.15 |
49.7 |
2.4 |
60.8 |
6935 |
250 |

|