نمایش منو

TiMF

 

Criteria

Standard Values

Unit

Conductor cross section

Nominal

0.5

0.75

1

1.5

2.5

mm²

Conductor DC Resistance @ 20oC

max.

36.7

25.0

18.5

12.3

7.4

Ohm/kM

Insulation resistance

min.

100

MOhm x km

Mutual capacitance

max.

250

nF/km

L/R (ratio)

max.

25

25

25

40

60

microH/Ohm

Test voltage :

for 1 minute

2.0 kV A.C or 3.0 kV D.C

K.V

core to core

core to screen

Operating voltage U(rms)

 

500

V

Nominal cross section area of conductor

Insulation thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

Kg/Km

meter

Conductor : 0.5 mm2 (7x0.3 mm)

1x3x0.5

0.6

0.9

7.0

64

1000

2x3x0.5

0.6

1.0

11.5

120

1000

3x3x0.5

0.6

1.0

12.2

159

1000

4x3x0.5

0.6

1.1

13.6

204

1000

5x3x0.5

0.6

1.1

14.9

245

1000

6x3x0.5

0.6

1.2

16.5

293

1000

7x3x0.5

0.6

1.2

16.5

328

1000

10x3x0.5

0.6

1.3

21.3

464

1000

12x3x0.5

0.6

1.3

22.0

538

1000

16x3x0.5

0.6

1.4

24.7

701

500

20x3x0.5

0.6

1.5

27.8

868

500

24x3x0.5

0.6

1.6

31.1

1038

500

30x3x0.5

0.6

1.7

33.2

1273

500

Conductor : 0.75 mm2 (7x0.37 mm)

1x3x0.75

0.6

0.9

7.4

76

1000

2x3x0.75

0.6

1.0

12.3

144

1000

3x3x0.75

0.6

1.1

13.3

197

1000

4x3x0.75

0.6

1.1

14.6

248

1000

5x3x0.75

0.6

1.2

16.3

305

1000

6x3x0.75

0.6

1.2

17.8

357

1000

7x3x0.75

0.6

1.2

17.8

402

1000

10x3x0.75

0.6

1.4

23.2

579

1000

12x3x0.75

0.6

1.4

24.0

673

1000

16x3x0.75

0.6

1.5

26.9

877

500

20x3x0.75

0.6

1.6

30.3

1087

500

24x3x0.75

0.6

1.7

33.8

1300

500

30x3x0.75

0.6

1.8

36.1

1596

500

Nominal cross section area of conductor

Insulation thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

Kg/Km

meter

Conductor : 1.0 mm2 (7x0.43 mm)

1x3x1

0.6

0.9

7.8

86

1000

2x3x1

0.6

1.1

13.3

170

1000

3x3x1

0.6

1.1

14.1

228

1000

4x3x1

0.6

1.1

15.5

288

1000

5x3x1

0.6

1.2

17.2

356

1000

6x3x1

0.6

1.2

18.9

418

1000

7x3x1

0.6

1.2

18.9

472

1000

10x3x1

0.6

1.4

24.6

679

500

12x3x1

0.6

1.4

25.5

792

500

16x3x1

0.6

1.5

28.6

1036

500

20x3x1

0.6

1.6

32.2

1285

500

24x3x1

0.6

1.8

36.2

1551

500

30x3x1

0.6

1.8

38.4

1891

500

Conductor : 1.5 mm2 (7x0.53 mm)

1x3x1.5

0.6

0.9

8.5

108

1000

2x3x1.5

0.6

1.1

14.5

213

1000

3x3x1.5

0.6

1.1

15.4

290

1000

4x3x1.5

0.6

1.2

17.2

377

1000

5x3x1.5

0.6

1.2

18.9

457

1000

6x3x1.5

0.6

1.3

20.9

547

1000

7x3x1.5

0.6

1.3

20.9

619

1000

10x3x1.5

0.6

1.5

27.3

890

500

12x3x1.5

0.6

1.5

28.2

1040

500

16x3x1.5

0.6

1.6

31.7

1362

500

20x3x1.5

0.6

1.8

35.9

1704

500

24x3x1.5

0.6

1.9

40.1

2038

500

30x3x1.5

0.6

2.0

42.7

2507

500

Nominal cross section area of conductor

Insulation thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

Kg/Km

meter

Conductor : 2.5 mm2 (7x0.67 mm)

1x3x2.5

0.7

1.0

10.0

154

1000

2x3x2.5

0.7

1.2

17.2

305

1000

3x3x2.5

0.7

1.2

18.4

419

1000

4x3x2.5

0.7

1.3

20.4

545

1000

5x3x2.5

0.7

1.4

22.7

674

1000

6x3x2.5

0.7

1.4

24.9

795

500

7x3x2.5

0.7

1.4

24.9

903

500

10x3x2.5

0.7

1.7

32.7

1309

500

12x3x2.5

0.7

1.7

33.9

1534

500

16x3x2.5

0.7

1.9

38.2

2024

500

20x3x2.5

0.7

2.0

43.0

2510

500

24x3x2.5

0.7

2.2

48.2

3020

500

30x3x2.5

0.7

2.3

51.4

3717

250