Multi-triple
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
40.4 |
26 |
19.2 |
12.8 |
7.86 |
Ohm/kM |
Insulation resistance |
min. |
100 |
MOhm x km |
||||
Mutual capacitance |
max. |
250 |
nF/km |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 5 minutes |
1.5 kV A.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
300 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.3 mm) |
|||||
1x3x0.5 |
0.6 |
1.0 |
7.4 |
76 |
1000 |
2x3x0.5 |
0.6 |
1.1 |
10.9 |
136 |
1000 |
3x3x0.5 |
0.6 |
1.2 |
11.7 |
172 |
1000 |
4x3x0.5 |
0.6 |
1.2 |
12.9 |
231 |
1000 |
5x3x0.5 |
0.6 |
1.3 |
14.2 |
271 |
1000 |
6x3x0.5 |
0.6 |
1.3 |
15.4 |
314 |
1000 |
7x3x0.5 |
0.6 |
1.3 |
15.4 |
341 |
1000 |
10x3x0.5 |
0.6 |
1.5 |
20.0 |
509 |
1000 |
12x3x0.5 |
0.6 |
1.5 |
20.6 |
568 |
1000 |
16x3x0.5 |
0.6 |
1.6 |
22.9 |
718 |
1000 |
20x3x0.5 |
0.6 |
1.7 |
25.6 |
869 |
500 |
24x3x0.5 |
0.6 |
1.8 |
28.4 |
1033 |
500 |
30x3x0.5 |
0.6 |
1.8 |
30.0 |
1214 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||
1x3x0.75 |
0.6 |
1.0 |
7.8 |
91 |
1000 |
2x3x0.75 |
0.6 |
1.2 |
11.9 |
164 |
1000 |
3x3x0.75 |
0.6 |
1.2 |
12.8 |
224 |
1000 |
4x3x0.75 |
0.6 |
1.3 |
14.1 |
281 |
1000 |
5x3x0.75 |
0.6 |
1.3 |
15.3 |
332 |
1000 |
6x3x0.75 |
0.6 |
1.4 |
16.8 |
393 |
1000 |
7x3x0.75 |
0.6 |
1.4 |
16.8 |
429 |
1000 |
10x3x0.75 |
0.6 |
1.5 |
21.5 |
628 |
1000 |
12x3x0.75 |
0.6 |
1.6 |
22.4 |
717 |
1000 |
16x3x0.75 |
0.6 |
1.6 |
24.8 |
891 |
500 |
20x3x0.75 |
0.6 |
1.8 |
27.9 |
1104 |
500 |
24x3x0.75 |
0.6 |
1.9 |
31.0 |
1298 |
500 |
30x3x0.75 |
0.6 |
1.9 |
32.7 |
1538 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||
1x3x1 |
0.6 |
1.0 |
8.2 |
103 |
1000 |
2x3x1 |
0.6 |
1.2 |
12.7 |
206 |
1000 |
3x3x1 |
0.6 |
1.2 |
13.5 |
263 |
1000 |
4x3x1 |
0.6 |
1.3 |
14.9 |
330 |
1000 |
5x3x1 |
0.6 |
1.3 |
16.2 |
385 |
1000 |
6x3x1 |
0.6 |
1.4 |
17.8 |
456 |
1000 |
7x3x1 |
0.6 |
1.4 |
17.8 |
501 |
1000 |
10x3x1 |
0.6 |
1.6 |
23.1 |
743 |
1000 |
12x3x1 |
0.6 |
1.6 |
23.8 |
840 |
1000 |
16x3x1 |
0.6 |
1.7 |
26.5 |
1067 |
500 |
20x3x1 |
0.6 |
1.8 |
29.7 |
1309 |
500 |
24x3x1 |
0.6 |
1.9 |
33.0 |
1545 |
500 |
30x3x1 |
0.6 |
2.0 |
35.1 |
1878 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||
1x3x1.5 |
0.7 |
1.1 |
9.5 |
138 |
1000 |
2x3x1.5 |
0.7 |
1.3 |
14.8 |
283 |
1000 |
3x3x1.5 |
0.7 |
1.3 |
15.7 |
356 |
1000 |
4x3x1.5 |
0.7 |
1.4 |
17.4 |
449 |
1000 |
5x3x1.5 |
0.7 |
1.4 |
19.2 |
561 |
1000 |
6x3x1.5 |
0.7 |
1.5 |
21.0 |
652 |
1000 |
7x3x1.5 |
0.7 |
1.5 |
21.0 |
719 |
1000 |
10x3x1.5 |
0.7 |
1.7 |
27.0 |
1019 |
500 |
12x3x1.5 |
0.7 |
1.7 |
27.9 |
1177 |
500 |
16x3x1.5 |
0.7 |
1.9 |
31.3 |
1510 |
500 |
20x3x1.5 |
0.7 |
2.0 |
35.0 |
1862 |
500 |
24x3x1.5 |
0.7 |
2.1 |
39.0 |
2195 |
500 |
30x3x1.5 |
0.7 |
2.2 |
41.5 |
2646 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||
1x3x2.5 |
0.7 |
1.1 |
10.4 |
178 |
1000 |
2x3x2.5 |
0.7 |
1.3 |
16.4 |
363 |
1000 |
3x3x2.5 |
0.7 |
1.4 |
17.6 |
477 |
1000 |
4x3x2.5 |
0.7 |
1.4 |
19.5 |
621 |
1000 |
5x3x2.5 |
0.7 |
1.5 |
21.5 |
756 |
1000 |
6x3x2.5 |
0.7 |
1.6 |
23.6 |
883 |
1000 |
7x3x2.5 |
0.7 |
1.6 |
23.6 |
980 |
1000 |
10x3x2.5 |
0.7 |
1.8 |
30.4 |
1393 |
500 |
12x3x2.5 |
0.7 |
1.9 |
31.6 |
1616 |
500 |
16x3x2.5 |
0.7 |
2.0 |
35.2 |
2090 |
500 |
20x3x2.5 |
0.7 |
2.1 |
39.4 |
2550 |
500 |
24x3x2.5 |
0.7 |
2.3 |
44.1 |
3055 |
500 |
30x3x2.5 |
0.7 |
2.4 |
46.9 |
3702 |
500 |

|