NA2XSEY
3.6/6 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x25rm/16 |
5.8 |
2.5 |
2.2 |
39.1 |
1925 |
500 |
3x35rm/16 |
7.0 |
2.5 |
2.3 |
41.8 |
2221 |
500 |
3x50rm/16 |
8.2 |
2.5 |
2.3 |
44.8 |
2619 |
500 |
3x70rm/16 |
9.9 |
2.5 |
2.4 |
48.7 |
3111 |
500 |
3x95rm/16 |
11.5 |
2.5 |
2.5 |
52.3 |
3639 |
500 |
3x120rm/16 |
13.0 |
2.5 |
2.6 |
56.1 |
4228 |
500 |
3x150rm/25 |
14.5 |
2.5 |
2.8 |
59.8 |
4838 |
500 |
3x185rm/25 |
16.1 |
2.5 |
2.9 |
64.3 |
5626 |
250 |
3x240rm/25 |
18.5 |
2.6 |
3.2 |
70.4 |
6785 |
250 |
3x300rm/25 |
20.6 |
2.8 |
3.4 |
77.5 |
8254 |
250 |
6/10 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x25rm/16 |
5.8 |
3.4 |
2.3 |
43.1 |
2313 |
500 |
3x35rm/16 |
7.0 |
3.4 |
2.3 |
46.1 |
2667 |
500 |
3x50rm/16 |
8.2 |
3.4 |
2.4 |
48.9 |
3039 |
500 |
3x70rm/16 |
9.9 |
3.4 |
2.6 |
52.9 |
3586 |
500 |
3x95rm/16 |
11.5 |
3.4 |
2.7 |
57.0 |
4214 |
500 |
3x120rm/16 |
13.0 |
3.4 |
2.8 |
60.4 |
4771 |
500 |
3x150rm/25 |
14.5 |
3.4 |
2.9 |
63.8 |
5383 |
250 |
3x185rm/25 |
16.1 |
3.4 |
3.0 |
68.3 |
6208 |
250 |
3x240rm/25 |
18.5 |
3.4 |
3.2 |
74.3 |
7407 |
250 |
3x300rm/25 |
20.6 |
3.4 |
3.3 |
79.9 |
8638 |
250 |
8.7/15 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x25rm/16 |
5.8 |
4.5 |
2.4 |
48.5 |
2864 |
500 |
3x35rm/16 |
7.0 |
4.5 |
2.5 |
51.2 |
3215 |
500 |
3x50rm/16 |
8.2 |
4.5 |
2.7 |
54.6 |
3706 |
500 |
3x70rm/16 |
9.9 |
4.5 |
2.7 |
58.3 |
4249 |
500 |
3x95rm/16 |
11.5 |
4.5 |
2.9 |
62.1 |
4888 |
500 |
3x120rm/16 |
13.0 |
4.5 |
3.0 |
65.5 |
5481 |
500 |
3x150rm/25 |
14.5 |
4.5 |
3.1 |
69.0 |
5717 |
250 |
3x185rm/25 |
16.1 |
4.5 |
3.2 |
73.9 |
7080 |
250 |
3x240rm/25 |
18.5 |
4.5 |
3.4 |
79.4 |
8264 |
250 |
12/20 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x35rm/16 |
7.0 |
5.5 |
2.7 |
56.3 |
3846 |
500 |
3x50rm/16 |
8.2 |
5.5 |
2.8 |
59.1 |
4278 |
500 |
3x70rm/16 |
9.9 |
5.5 |
2.9 |
63.0 |
4868 |
500 |
3x95rm/16 |
11.5 |
5.5 |
3.0 |
66.6 |
5504 |
250 |
3x120rm/16 |
13.0 |
5.5 |
3.1 |
70.0 |
6128 |
250 |
3x150rm/25 |
14.5 |
5.5 |
3.2 |
73.9 |
6895 |
250 |
3x185rm/25 |
16.1 |
5.5 |
3.3 |
78.4 |
7830 |
250 |
3x240rm/25 |
18.5 |
5.5 |
3.6 |
84.1 |
9096 |
250 |

|