نمایش منو

Cu-XLPE-SC-PVC-LC-PVC-AWA-PVC

3.6/6 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diameter

Insulation thickness

Diameter Under Armour

Armour Wire Diameter

Diameter Over Lead Sheath

Lead Sheath Thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

mm

mm

Kg/Km

meter

1x25rm/16

5.8

2.5

23.5

1.6

21.5

1.3

1.9

30.5

2111

1000

1x35rm/16

7.0

2.5

24.7

1.6

22.7

1.3

1.9

31.7

2302

1000

1x50rm/16

8.2

2.5

26.1

1.6

24.1

1.4

2.0

33.3

2642

1000

1x70rm/16

9.9

2.5

28.0

2.0

25.8

1.4

2.0

36.0

3076

1000

1x95rm/16

11.5

2.5

29.8

2.0

27.6

1.5

2.1

38.0

3570

1000

1x120rm/16

13.0

2.5

31.3

2.0

29.1

1.5

2.1

39.5

3933

500

1x150rm/25

14.5

2.5

33.2

2.0

30.8

1.6

2.2

41.6

4584

500

1x185rm/25

16.1

2.5

35.6

2.0

33.2

1.6

2.3

44.2

5173

500

1x240rm/25

18.5

2.6

38.4

2.0

36.0

1.7

2.4

47.2

6091

500

1x300rm/25

20.6

2.8

41.5

2.5

38.9

1.7

2.5

51.5

7161

500

1x400rm/35

23.2

3.0

45.1

2.5

42.3

1.9

2.6

55.3

8835

500

1x500rm/35

26.3

3.2

49.0

2.5

46.2

1.9

2.7

59.4

10262

500

6/10 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diamater

Insulation thickness

Diameter Under Armour

Armour Wire Diameter

Diameter Over Lead Sheath

Lead Sheath Thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

mm

mm

Kg/Km

meter

1x25rm/16

5.8

3.4

25.5

1.6

23.5

1.4

1.9

32.5

2371

1000

1x35rm/16

7.0

3.4

26.9

1.6

24.7

1.4

2.0

34.1

2605

1000

1x50rm/16

8.2

3.4

28.1

2.0

25.9

1.4

2.0

36.1

2938

500

1x70rm/16

9.9

3.4

30.0

2.0

27.8

1.5

2.1

38.2

3397

500

1x95rm/16

11.5

3.4

31.6

2.0

29.4

1.5

2.2

40.0

3799

500

1x120rm/16

13.0

3.4

33.5

2.0

31.1

1.6

2.2

41.9

4299

500

1x150rm/25

14.5

3.4

35.4

2.0

33.0

1.6

2.3

44.0

4886

500

1x185rm/25

16.1

3.4

37.6

2.0

35.2

1.7

2.3

46.2

5535

500

1x240rm/25

18.5

3.4

40.2

2.5

37.6

1.7

2.5

50.2

6505

500

1x300rm/25

20.6

3.4

42.9

2.5

40.3

1.8

2.5

52.9

7487

500

1x400rm/35

23.2

3.4

47.0

2.5

44.2

1.9

2.7

57.4

9140

500

1x500rm/35

26.3

3.4

50.8

2.5

48.0

2.0

2.8

61.4

10665

500

8.7/15 kV (IEC 60502 - 2)

Nominal cross section area of conduc tor

Conductor Diameter

Insulation thickness

Diameter Under Armour

Armour Wire Diameter

Diame ter Over Lead Sheath

Lead Sheath Thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

mm

mm

Kg/Km

meter

1x25rm/16

5.8

4.5

27.9

2.0

25.7

1.4

2.0

35.9

2715

1000

1x35rm/16

7.0

4.5

29.3

2.0

27.1

1.5

2.1

37.5

3042

1000

1x50rm/16

8.2

4.5

30.5

2.0

28.3

1.5

2.1

38.7

3299

1000

1x70rm/16

9.9

4.5

32.4

2.0

30.0

1.5

2.2

40.8

3690

1000

1x95rm/16

11.5

4.5

34.6

2.0

32.2

1.6

2.3

43.2

4277

1000

1x120rm/16

13.0

4.5

36.1

2.0

33.7

1.6

2.3

44.7

4648

1000

1x150rm/25

14.5

4.5

37.8

2.0

35.4

1.7

2.4

46.6

5322

500

1x185rm/25

16.1

4.5

40.0

2.5

37.4

1.7

2.5

50.0

6066

500

1x240rm/25

18.5

4.5

42.6

2.5

40.0

1.8

2.5

52.6

6964

500

1x300rm/25

20.6

4.5

45.3

2.5

42.5

1.8

2.6

55.5

8530

500

1x400rm/35

23.2

4.5

48.5

2.5

45.7

1.9

2.7

58.9

9424

500

1x500rm/35

26.3

4.5

52.0

2.5

49.0

2.0

2.8

62.6

10916

500

12/20 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diameter

Insulation thickness

Diameter Under Armour

Armour Wire Diameter

Diameter Over Lead Sheath

Lead Sheath Thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

mm

mm

Kg/Km

meter

1x25rm/16

5.8

5.5

30.1

2.0

27.9

1.5

2.1

38.3

3051

500

1x35rm/16

7.0

5.5

31.3

2.0

29.1

1.5

2.2

39.7

3285

500

1x50rm/16

8.2

5.5

32.9

2.0

30.5

1.6

2.2

41.3

3677

1000

1x70rm/16

9.9

5.5

35.0

2.0

32.6

1.6

2.3

43.6

4128

1000

1x95rm/16

11.5

5.5

36.6

2.0

34.2

1.6

2.3

45.2

4532

1000

1x120rm/16

13.0

5.5

38.5

2.5

35.9

1.7

2.4

48.3

5234

500

1x150rm/25

14.5

5.5

40.0

2.5

37.4

1.7

2.5

50.0

5792

500

1x185rm/25

16.1

5.5

42.2

2.5

39.6

1.8

2.5

52.2

6494

500

1x240rm/25

18.5

5.5

44.8

2.5

42.0

1.8

2.6

55.0

7322

500

1x300rm/25

20.6

5.5

47.9

2.5

45.1

1.9

2.7

58.3

8430

500

1x400rm/35

23.2

5.5

50.9

2.5

47.9

2.0

2.8

61.5

9972

500

1x500rm/35

26.3

5.5

55.1

2.5

51.9

2.1

3.0

66.1

11616

250

18/30 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diameter

Insulation thickness

Diameter Under Armour

Armour Wire Diameter

Diameter Over Lead Sheath

Lead Sheath Thickness

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

mm

mm

Kg/Km

meter

1x50rm/16

8.2

8.0

38.7

2.5

36.1

1.7

2.4

48.5

4724

500

1x70rm/16

9.9

8.0

40.4

2.5

37.8

1.7

2.5

50.4

5138

500

1x95rm/16

11.5

8.0

42.2

2.5

39.6

1.8

2.6

52.4

5725

500

1x120rm/16

13.0

8.0

43.9

2.5

41.1

1.8

2.6

54.1

6166

500

1x150rm/25

14.5

8.0

46.0

2.5

43.2

1.9

2.7

56.4

6970

500

1x185rm/25

16.1

8.0

48.0

2.5

45.2

1.9

2.7

58.4

7600

500

1x240rm/25

18.5

8.0

50.8

2.5

47.8

2.0

2.8

61.4

8606

500

1x300rm/25

20.6

8.0

53.5

2.5

50.5

2.1

2.9

64.3

9749

250