N2XSEYRY

581

3.6/6 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diamater

Insulation thickness

Diameter Under Armour

Armour Wire Diameter

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

Kg/Km

meter

3x25rm/16

5.8

2.5

34.7

2.0

2.3

43.3

3679

1000

3x35rm/16

7.0

2.5

37.4

2.0

2.3

46.0

4237

500

3x50rm/16

8.2

2.5

40.0

2.5

2.5

50.0

5393

500

3x70rm/16

9.9

2.5

43.9

2.5

2.6

54.1

6442

500

3x95rm/16

11.5

2.5

47.5

2.5

2.7

57.9

7584

500

3x120rm/16

13.0

2.5

50.7

2.5

2.8

61.3

8697

500

3x150rm/25

14.5

2.5

54.2

2.5

3.0

65.2

10013

250

3x185rm/25

16.1

2.5

58.5

2.5

3.0

69.5

11562

250

3x240rm/25

18.5

2.6

64.5

3.2

3.4

77.6

14930

250

3x300rm/25

20.6

2.8

70.9

3.2

3.5

84.2

17682

250

6/10 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diamater

Insulation thickness

Diameter Under Armour

Armour Wire Diameter

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

Kg/Km

meter

3x25rm/16

5.8

3.4

38.7

2.5

2.4

48.5

4623

500

3x35rm/16

7.0

3.4

41.3

2.5

2.5

51.3

5227

500

3x50rm/16

8.2

3.4

44.1

2.5

2.6

54.3

5994

500

3x70rm/16

9.9

3.4

47.9

2.5

2.7

58.3

7075

500

3x95rm/16

11.5

3.4

51.4

2.5

2.9

62.2

8249

500

3x120rm/16

13.0

3.4

54.8

2.5

3.0

65.8

9417

250

3x150rm/25

14.5

3.4

58.2

2.5

3.1

69.4

10734

250

3x185rm/25

16.1

3.4

62.5

3.2

3.2

75.2

13237

250

3x240rm/25

18.5

3.4

67.9

3.2

3.4

81.0

15648

250

3x300rm/25

20.6

3.4

73.3

3.2

3.6

86.8

19395

250

8.7/15 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diamater

Insulation thickness

Diameter Under Armour

Armour Wire Diameter

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

Kg/Km

meter

3x25rm/16

 

4.5

43.7

2.5

2.6

53.9

5317

500

3x35rm/16

7.0

4.5

46.2

2.5

2.7

56.6

6002

500

3x50rm/16

8.2

4.5

49.0

2.5

2.8

59.6

6786

500

3x70rm/16

9.9

4.5

52.9

2.5

3.0

63.9

7894

250

3x95rm/16

11.5

4.5

56.3

2.5

3.1

67.5

6618

500

3x120rm/16

13.0

4.5

59.7

2.5

3.1

70.9

10210

250

3x150rm/25

14.5

4.5

63.2

3.2

3.3

76.1

12523

250

3x185rm/25

16.1

4.5

67.5

3.2

3.4

80.6

14249

250

3x240rm/25

18.5

4.5

72.8

3.2

3.6

86.3

16708

250

3x300rm/25

20.6

4.5

78.4

4.0

3.8

94.0

20884

250

12/20 kV (IEC 60502 - 2)

Nominal cross section area of conductor

Conductor Diamater

Insulation thickness

Diameter Under Armour

Armour Wire Diameter

Sheath thickness

Overall Diameter

Weight

Standard Packing Length

mm2

mm

mm

mm

mm

mm

mm

Kg/Km

meter

3x35rm/16

7.0

5.5

50.7

2.5

2.8

61.3

6695

500

3x50rm/16

8.2

5.5

53.5

2.5

2.9

64.3

7512

250

3x70rm/16

9.9

5.5

57.2

2.5

3.0

68.2

8598

250

3x95rm/16

11.5

5.5

60.8

3.2

3.2

73.5

10753

250

3x120rm/16

13.0

5.5

64.2

3.2

3.4

77.3

12063

250

3x150rm/25

14.5

5.5

67.5

3.2

3.4

80.6

13401

250

3x185rm/25

16.1

5.5

72.0

3.2

3.6

85.5

15230

250

3x240rm/25

18.5

5.5

77.3

4.0

3.8

92.9

19179

250