Multi-Pair
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
36.7 |
25.0 |
18.5 |
12.3 |
7.4 |
Ohm/kM |
Insulation resistance |
min. |
100 |
MOhm x km |
||||
Mutual capacitance |
max. |
250 |
nF/km |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 1 minute |
2.0 kV A.C or 3.0 kV D.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
500 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Lead Sheath Thickness |
Diameter Over Lead Sheath |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.30 mm) |
|||||||||
1x2x0.5 |
0.6 |
0.9 |
8.3 |
0.9 |
8.5 |
1.4 |
13.1 |
526 |
1000 |
2x2x0.5 |
0.6 |
0.9 |
11.0 |
0.9 |
11.2 |
1.4 |
15.8 |
695 |
1000 |
3x2x0.5 |
0.6 |
1.0 |
11.7 |
0.9 |
11.7 |
1.4 |
16.3 |
775 |
1000 |
4x2x0.5 |
0.6 |
1.0 |
12.6 |
0.9 |
12.6 |
1.5 |
17.4 |
853 |
1000 |
5x2x0.5 |
0.6 |
1.0 |
13.6 |
0.9 |
13.6 |
1.5 |
18.4 |
927 |
1000 |
6x2x0.5 |
0.6 |
1.0 |
14.6 |
0.9 |
14.6 |
1.5 |
19.4 |
1010 |
1000 |
7x2x0.5 |
0.6 |
1.0 |
14.6 |
0.9 |
14.6 |
1.5 |
19.4 |
1027 |
1000 |
10x2x0.5 |
0.6 |
1.1 |
18.3 |
1.25 |
18.1 |
1.6 |
23.8 |
1492 |
1000 |
12x2x0.5 |
0.6 |
1.1 |
18.8 |
1.25 |
18.6 |
1.6 |
24.3 |
1563 |
1000 |
16x2x0.5 |
0.6 |
1.2 |
20.9 |
1.25 |
20.5 |
1.7 |
26.4 |
1830 |
1000 |
20x2x0.5 |
0.6 |
1.2 |
23.0 |
1.25 |
22.6 |
1.7 |
28.5 |
2057 |
1000 |
24x2x0.5 |
0.6 |
1.3 |
25.6 |
1.25 |
25.0 |
1.8 |
31.1 |
2387 |
500 |
30x2x0.5 |
0.6 |
1.3 |
27.0 |
1.25 |
26.4 |
1.8 |
32.5 |
2597 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||||||
1x2x0.75 |
0.6 |
0.9 |
8.7 |
0.9 |
8.9 |
1.4 |
13.5 |
556 |
1000 |
2x2x0.75 |
0.6 |
1.0 |
11.9 |
0.9 |
11.9 |
1.4 |
16.5 |
786 |
1000 |
3x2x0.75 |
0.6 |
1.0 |
12.5 |
0.9 |
12.5 |
1.5 |
17.3 |
853 |
1000 |
4x2x0.75 |
0.6 |
1.0 |
13.5 |
0.9 |
13.5 |
1.5 |
18.3 |
935 |
1000 |
5x2x0.75 |
0.6 |
1.0 |
14.5 |
0.9 |
14.5 |
1.5 |
19.3 |
1025 |
1000 |
6x2x0.75 |
0.6 |
1.1 |
15.9 |
0.9 |
15.7 |
1.5 |
20.5 |
1161 |
1000 |
7x2x0.75 |
0.6 |
1.1 |
15.9 |
0.9 |
15.7 |
1.5 |
20.5 |
1185 |
1000 |
10x2x0.75 |
0.6 |
1.1 |
19.6 |
1.25 |
19.4 |
1.6 |
25.1 |
1657 |
1000 |
12x2x0.75 |
0.6 |
1.2 |
20.4 |
1.25 |
20.0 |
1.7 |
25.9 |
1814 |
1000 |
16x2x0.75 |
0.6 |
1.2 |
22.5 |
1.25 |
22.1 |
1.7 |
28.0 |
2061 |
1000 |
20x2x0.75 |
0.6 |
1.3 |
25.1 |
1.25 |
24.5 |
1.8 |
30.6 |
2420 |
500 |
24x2x0.75 |
0.6 |
1.3 |
27.6 |
1.25 |
27.0 |
1.8 |
33.1 |
2709 |
500 |
30x2x0.75 |
0.6 |
1.4 |
29.4 |
1.25 |
28.6 |
1.8 |
34.7 |
3051 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Lead Sheath Thickness |
Diameter Over Lead Sheath |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||||||
1x2x1 |
0.6 |
0.9 |
9.1 |
0.9 |
9.3 |
1.4 |
13.9 |
578 |
1000 |
2x2x1 |
0.6 |
1.0 |
12.5 |
0.9 |
12.5 |
1.5 |
17.3 |
833 |
1000 |
3x2x1 |
0.6 |
1.0 |
13.1 |
0.9 |
13.1 |
1.5 |
17.9 |
901 |
1000 |
4x2x1 |
0.6 |
1.0 |
14.2 |
0.9 |
14.2 |
1.5 |
19.0 |
991 |
1000 |
5x2x1 |
0.6 |
1.0 |
15.3 |
0.9 |
15.3 |
1.5 |
20.1 |
1090 |
1000 |
6x2x1 |
0.6 |
1.1 |
16.7 |
0.9 |
16.5 |
1.5 |
21.3 |
1242 |
1000 |
7x2x1 |
0.6 |
1.1 |
16.7 |
0.9 |
16.5 |
1.5 |
21.3 |
1272 |
1000 |
10x2x1 |
0.6 |
1.2 |
21.0 |
1.25 |
20.6 |
1.7 |
26.5 |
1859 |
1000 |
12x2x1 |
0.6 |
1.2 |
21.7 |
1.25 |
21.3 |
1.7 |
27.2 |
1960 |
1000 |
16x2x1 |
0.6 |
1.2 |
23.9 |
1.25 |
23.5 |
1.7 |
29.4 |
2237 |
500 |
20x2x1 |
0.6 |
1.3 |
26.7 |
1.25 |
26.1 |
1.8 |
32.2 |
2631 |
500 |
24x2x1 |
0.6 |
1.4 |
29.6 |
1.25 |
28.8 |
1.8 |
34.9 |
3047 |
500 |
30x2x1 |
0.6 |
1.4 |
31.3 |
1.6 |
30.5 |
1.9 |
37.5 |
3599 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||||||
1x2x1.5 |
0.6 |
0.9 |
9.7 |
0.9 |
9.9 |
1.4 |
14.5 |
628 |
1000 |
2x2x1.5 |
0.6 |
1.0 |
13.4 |
0.9 |
13.4 |
1.5 |
18.2 |
923 |
1000 |
3x2x1.5 |
0.6 |
1.0 |
14.2 |
0.9 |
14.2 |
1.5 |
19.0 |
1007 |
1000 |
4x2x1.5 |
0.6 |
1.0 |
15.4 |
0.9 |
15.4 |
1.5 |
20.2 |
1121 |
1000 |
5x2x1.5 |
0.6 |
1.1 |
16.8 |
0.9 |
16.6 |
1.6 |
21.6 |
1298 |
1000 |
6x2x1.5 |
0.6 |
1.1 |
18.2 |
1.25 |
18.0 |
1.6 |
23.7 |
1565 |
1000 |
7x2x1.5 |
0.6 |
1.1 |
18.2 |
1.25 |
18.0 |
1.6 |
23.7 |
1607 |
1000 |
10x2x1.5 |
0.6 |
1.2 |
23.0 |
1.25 |
22.6 |
1.7 |
28.5 |
2134 |
1000 |
12x2x1.5 |
0.6 |
1.2 |
23.7 |
1.25 |
23.3 |
1.7 |
29.2 |
2274 |
500 |
16x2x1.5 |
0.6 |
1.3 |
26.4 |
1.25 |
25.8 |
1.8 |
31.9 |
2715 |
500 |
20x2x1.5 |
0.6 |
1.4 |
29.5 |
1.25 |
28.7 |
1.9 |
35.0 |
3205 |
500 |
24x2x1.5 |
0.6 |
1.4 |
32.5 |
1.6 |
31.7 |
1.9 |
38.7 |
3843 |
500 |
30x2x1.5 |
0.6 |
1.5 |
34.6 |
1.6 |
34.0 |
2.0 |
41.2 |
4434 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Lead Sheath Thickness |
Diameter Over Lead Sheath |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||||||
1x2x2.5 |
0.7 |
0.9 |
10.9 |
0.9 |
11.1 |
1.4 |
15.7 |
728 |
1000 |
2x2x2.5 |
0.7 |
1.1 |
15.7 |
0.9 |
15.5 |
1.5 |
20.3 |
1153 |
1000 |
3x2x2.5 |
0.7 |
1.1 |
16.6 |
0.9 |
16.4 |
1.6 |
21.4 |
1284 |
1000 |
4x2x2.5 |
0.7 |
1.1 |
18.0 |
1.25 |
17.8 |
1.6 |
23.5 |
1580 |
1000 |
5x2x2.5 |
0.7 |
1.2 |
19.8 |
1.25 |
19.4 |
1.7 |
25.3 |
1830 |
1000 |
6x2x2.5 |
0.7 |
1.2 |
21.5 |
1.25 |
21.1 |
1.7 |
27.0 |
2020 |
1000 |
7x2x2.5 |
0.7 |
1.2 |
21.5 |
1.25 |
21.1 |
1.7 |
27.0 |
2085 |
1000 |
10x2x2.5 |
0.7 |
1.3 |
27.3 |
1.25 |
26.7 |
1.8 |
32.8 |
2789 |
500 |
12x2x2.5 |
0.7 |
1.4 |
28.4 |
1.25 |
27.6 |
1.8 |
33.7 |
3072 |
500 |
16x2x2.5 |
0.7 |
1.4 |
31.4 |
1.6 |
30.6 |
1.9 |
37.6 |
3815 |
500 |
20x2x2.5 |
0.7 |
1.5 |
35.5 |
1.6 |
34.9 |
2.0 |
42.1 |
4618 |
500 |
24x2x2.5 |
0.7 |
1.6 |
39.4 |
2 |
38.6 |
2.1 |
46.8 |
5699 |
500 |
30x2x2.5 |
0.7 |
1.7 |
41.9 |
2 |
40.9 |
2.2 |
49.3 |
6462 |
500 |

|