Multi-Triple
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
36.7 |
25.0 |
18.5 |
12.3 |
7.4 |
Ohm/kM |
Insulation resistance |
min. |
1000 |
MOhm x km |
||||
Mutual capacitance |
max. |
150 |
nF/km |
||||
Capacitance unbalance |
max. |
500 |
pF/500m |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 1 minute |
2.0 kV A.C or 3.0 kV D.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
500 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Armour Tape Thickness |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.30 mm) |
|||||||
1x3x0.5 |
0.6 |
0.2 |
7.9 |
1.3 |
11.3 |
182 |
1000 |
2x3x0.5 |
0.6 |
0.2 |
11.9 |
1.4 |
15.5 |
286 |
1000 |
3x3x0.5 |
0.6 |
0.2 |
12.7 |
1.4 |
16.3 |
328 |
1000 |
4x3x0.5 |
0.6 |
0.2 |
14.0 |
1.4 |
17.6 |
378 |
1000 |
5x3x0.5 |
0.6 |
0.2 |
15.3 |
1.5 |
19.1 |
438 |
1000 |
6x3x0.5 |
0.6 |
0.2 |
16.7 |
1.5 |
20.5 |
492 |
1000 |
7x3x0.5 |
0.6 |
0.2 |
16.7 |
1.5 |
20.5 |
521 |
1000 |
10x3x0.5 |
0.6 |
0.2 |
21.6 |
1.6 |
25.6 |
702 |
500 |
12x3x0.5 |
0.6 |
0.2 |
22.3 |
1.6 |
26.3 |
773 |
500 |
16x3x0.5 |
0.6 |
0.2 |
24.9 |
1.7 |
29.1 |
946 |
500 |
20x3x0.5 |
0.6 |
0.2 |
28.0 |
1.7 |
32.2 |
1117 |
500 |
24x3x0.5 |
0.6 |
0.2 |
31.2 |
1.8 |
35.6 |
1304 |
500 |
30x3x0.5 |
0.6 |
0.2 |
33.2 |
1.8 |
37.6 |
1513 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||||
1x3x0.75 |
0.6 |
0.2 |
8.3 |
1.3 |
11.7 |
199 |
1000 |
2x3x0.75 |
0.6 |
0.2 |
12.7 |
1.4 |
16.3 |
319 |
1000 |
3x3x0.75 |
0.6 |
0.2 |
13.5 |
1.4 |
17.1 |
371 |
1000 |
4x3x0.75 |
0.6 |
0.2 |
14.9 |
1.5 |
18.7 |
439 |
1000 |
5x3x0.75 |
0.6 |
0.2 |
16.4 |
1.5 |
20.2 |
503 |
1000 |
6x3x0.75 |
0.6 |
0.2 |
17.9 |
1.5 |
21.7 |
569 |
1000 |
7x3x0.75 |
0.6 |
0.2 |
17.9 |
1.5 |
21.7 |
607 |
1000 |
10x3x0.75 |
0.6 |
0.2 |
23.1 |
1.6 |
27.1 |
823 |
500 |
12x3x0.75 |
0.6 |
0.2 |
24.0 |
1.6 |
28.0 |
913 |
500 |
16x3x0.75 |
0.6 |
0.2 |
26.8 |
1.7 |
31.0 |
1127 |
500 |
20x3x0.75 |
0.6 |
0.2 |
30.1 |
1.8 |
34.5 |
1351 |
500 |
24x3x0.75 |
0.6 |
0.2 |
33.6 |
1.8 |
38.0 |
1568 |
500 |
30x3x0.75 |
0.6 |
0.2 |
36.1 |
1.9 |
40.7 |
1889 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Tape Thickness |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||||
1x3x1 |
0.6 |
0.2 |
8.7 |
1.3 |
12.1 |
214 |
1000 |
2x3x1 |
0.6 |
0.2 |
13.4 |
1.4 |
17.0 |
347 |
1000 |
3x3x1 |
0.6 |
0.2 |
14.3 |
1.4 |
17.9 |
409 |
1000 |
4x3x1 |
0.6 |
0.2 |
15.7 |
1.5 |
19.5 |
489 |
1000 |
5x3x1 |
0.6 |
0.2 |
17.3 |
1.5 |
21.1 |
563 |
1000 |
6x3x1 |
0.6 |
0.2 |
18.9 |
1.5 |
22.7 |
639 |
1000 |
7x3x1 |
0.6 |
0.2 |
18.9 |
1.5 |
22.7 |
686 |
1000 |
10x3x1 |
0.6 |
0.2 |
24.5 |
1.6 |
28.5 |
934 |
500 |
12x3x1 |
0.6 |
0.2 |
25.4 |
1.7 |
29.6 |
1055 |
500 |
16x3x1 |
0.6 |
0.2 |
28.4 |
1.7 |
32.6 |
1296 |
500 |
20x3x1 |
0.6 |
0.2 |
31.9 |
1.8 |
36.3 |
1561 |
500 |
24x3x1 |
0.6 |
0.2 |
35.6 |
1.9 |
40.2 |
1831 |
500 |
30x3x1 |
0.6 |
0.2 |
38.3 |
1.9 |
42.9 |
2196 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||||
1x3x1.5 |
0.6 |
0.2 |
9.4 |
1.3 |
12.8 |
244 |
1000 |
2x3x1.5 |
0.6 |
0.2 |
14.5 |
1.5 |
18.3 |
410 |
1000 |
3x3x1.5 |
0.6 |
0.2 |
15.5 |
1.5 |
19.3 |
492 |
1000 |
4x3x1.5 |
0.6 |
0.2 |
17.1 |
1.5 |
20.9 |
584 |
1000 |
5x3x1.5 |
0.6 |
0.2 |
18.8 |
1.5 |
22.6 |
679 |
1000 |
6x3x1.5 |
0.6 |
0.2 |
20.6 |
1.6 |
24.6 |
785 |
500 |
7x3x1.5 |
0.6 |
0.2 |
20.6 |
1.6 |
24.6 |
849 |
500 |
10x3x1.5 |
0.6 |
0.2 |
26.7 |
1.7 |
30.9 |
1164 |
500 |
12x3x1.5 |
0.6 |
0.2 |
27.7 |
1.7 |
31.9 |
1310 |
500 |
16x3x1.5 |
0.6 |
0.2 |
31.0 |
1.8 |
35.4 |
1640 |
500 |
20x3x1.5 |
0.6 |
0.2 |
35.3 |
1.9 |
39.9 |
2022 |
500 |
24x3x1.5 |
0.6 |
0.5 |
39.3 |
2.0 |
45.3 |
2849 |
500 |
30x3x1.5 |
0.6 |
0.5 |
41.9 |
2.1 |
48.1 |
3330 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Tape Thickness |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||||
1x3x2.5 |
0.7 |
0.2 |
10.7 |
1.4 |
14.3 |
307 |
1000 |
2x3x2.5 |
0.7 |
0.2 |
16.8 |
1.5 |
20.6 |
520 |
1000 |
3x3x2.5 |
0.7 |
0.2 |
18.0 |
1.5 |
21.8 |
638 |
1000 |
4x3x2.5 |
0.7 |
0.2 |
19.9 |
1.6 |
23.9 |
778 |
1000 |
5x3x2.5 |
0.7 |
0.2 |
21.9 |
1.6 |
25.9 |
912 |
500 |
6x3x2.5 |
0.7 |
0.2 |
24.1 |
1.7 |
28.3 |
1060 |
500 |
7x3x2.5 |
0.7 |
0.2 |
24.1 |
1.7 |
28.3 |
1157 |
500 |
10x3x2.5 |
0.7 |
0.2 |
31.4 |
1.8 |
35.8 |
1598 |
500 |
12x3x2.5 |
0.7 |
0.2 |
32.5 |
1.9 |
37.1 |
1827 |
500 |
16x3x2.5 |
0.7 |
0.2 |
36.8 |
2.0 |
41.6 |
2347 |
500 |
20x3x2.5 |
0.7 |
0.5 |
41.4 |
2.1 |
47.6 |
3343 |
500 |
24x3x2.5 |
0.7 |
0.5 |
46.3 |
2.2 |
52.7 |
3908 |
250 |
30x3x2.5 |
0.7 |
0.5 |
49.7 |
2.3 |
56.3 |
4665 |
250 |

|