Multi-Core
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
36.7 |
25.0 |
18.5 |
12.3 |
7.4 |
Ohm/kM |
Insulation resistance |
min. |
100 |
MOhm x km |
||||
Mutual capacitance |
max. |
250 |
nF/km |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 1 minute |
2.0 kV A.C or 3.0 kV D.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
500 |
V |
EN 50288-7 (500 V)
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.3 mm) |
|||||
2x0.5 |
0.6 |
0.9 |
6.3 |
44 |
1000 |
3x0.5 |
0.6 |
0.9 |
6.6 |
54 |
1000 |
4x0.5 |
0.6 |
0.9 |
7.2 |
65 |
1000 |
5x0.5 |
0.6 |
0.9 |
7.8 |
76 |
1000 |
6x0.5 |
0.6 |
0.9 |
8.4 |
87 |
1000 |
7x0.5 |
0.6 |
0.9 |
8.4 |
96 |
1000 |
8x0.5 |
0.6 |
1.0 |
9.8 |
113 |
1000 |
10x0.5 |
0.6 |
1.0 |
10.7 |
134 |
1000 |
12x0.5 |
0.6 |
1.0 |
11.0 |
153 |
1000 |
16x0.5 |
0.6 |
1.0 |
12.2 |
193 |
1000 |
20x0.5 |
0.6 |
1.1 |
13.7 |
238 |
1000 |
24x0.5 |
0.6 |
1.1 |
15.1 |
280 |
1000 |
30x0.5 |
0.6 |
1.2 |
16.1 |
342 |
1000 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||
2x0.75 |
0.6 |
0.9 |
6.7 |
52 |
1000 |
3x0.75 |
0.6 |
0.9 |
7.1 |
65 |
1000 |
4x0.75 |
0.6 |
0.9 |
7.7 |
79 |
1000 |
5x0.75 |
0.6 |
0.9 |
8.3 |
93 |
1000 |
6x0.75 |
0.6 |
0.9 |
9.0 |
108 |
1000 |
7x0.75 |
0.6 |
0.9 |
9.0 |
120 |
1000 |
8x0.75 |
0.6 |
1.0 |
10.6 |
141 |
1000 |
10x0.75 |
0.6 |
1.0 |
11.5 |
168 |
1000 |
12x0.75 |
0.6 |
1.0 |
11.9 |
193 |
1000 |
16x0.75 |
0.6 |
1.1 |
13.3 |
251 |
1000 |
20x0.75 |
0.6 |
1.1 |
14.8 |
305 |
1000 |
24x0.75 |
0.6 |
1.2 |
16.5 |
365 |
1000 |
30x0.75 |
0.6 |
1.2 |
17.5 |
440 |
1000 |
EN 50288-7 (500 V)
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||
2x1 |
0.6 |
0.9 |
7.1 |
59 |
1000 |
3x1 |
0.6 |
0.9 |
7.5 |
75 |
1000 |
4x1 |
0.6 |
0.9 |
8.1 |
92 |
1000 |
5x1 |
0.6 |
0.9 |
8.8 |
110 |
1000 |
6x1 |
0.6 |
1.0 |
9.8 |
131 |
1000 |
7x1 |
0.6 |
1.0 |
9.8 |
146 |
1000 |
8x1 |
0.6 |
1.0 |
11.3 |
167 |
1000 |
10x1 |
0.6 |
1.0 |
12.2 |
200 |
1000 |
12x1 |
0.6 |
1.0 |
12.6 |
232 |
1000 |
16x1 |
0.6 |
1.1 |
14.2 |
302 |
1000 |
20x1 |
0.6 |
1.1 |
15.8 |
368 |
1000 |
24x1 |
0.6 |
1.2 |
17.6 |
441 |
1000 |
30x1 |
0.6 |
1.2 |
18.6 |
534 |
1000 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||
2x1.5 |
0.6 |
0.9 |
7.7 |
73 |
1000 |
3x1.5 |
0.6 |
0.9 |
8.1 |
96 |
1000 |
4x1.5 |
0.6 |
0.9 |
8.8 |
119 |
1000 |
5x1.5 |
0.6 |
1.0 |
9.8 |
146 |
1000 |
6x1.5 |
0.6 |
1.0 |
10.7 |
171 |
1000 |
7x1.5 |
0.6 |
1.0 |
10.7 |
191 |
1000 |
8x1.5 |
0.6 |
1.0 |
12.3 |
219 |
1000 |
10x1.5 |
0.6 |
1.1 |
13.6 |
270 |
1000 |
12x1.5 |
0.6 |
1.1 |
14.1 |
313 |
1000 |
16x1.5 |
0.6 |
1.1 |
15.6 |
402 |
1000 |
20x1.5 |
0.6 |
1.2 |
17.6 |
499 |
1000 |
24x1.5 |
0.6 |
1.3 |
19.6 |
599 |
1000 |
30x1.5 |
0.6 |
1.3 |
20.8 |
728 |
1000 |
EN 50288-7 (500 V)
Nominal cross section area of conductor |
Insulation thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||
2x2.5 |
0.7 |
0.9 |
8.9 |
102 |
1000 |
3x2.5 |
0.7 |
1.0 |
9.7 |
140 |
1000 |
4x2.5 |
0.7 |
1.0 |
10.5 |
175 |
1000 |
5x2.5 |
0.7 |
1.0 |
11.5 |
211 |
1000 |
6x2.5 |
0.7 |
1.1 |
12.7 |
253 |
1000 |
7x2.5 |
0.7 |
1.1 |
12.7 |
285 |
1000 |
8x2.5 |
0.7 |
1.1 |
14.8 |
326 |
1000 |
10x2.5 |
0.7 |
1.2 |
16.3 |
403 |
1000 |
12x2.5 |
0.7 |
1.2 |
16.9 |
470 |
1000 |
16x2.5 |
0.7 |
1.3 |
18.9 |
615 |
1000 |
20x2.5 |
0.7 |
1.3 |
21.1 |
754 |
1000 |
24x2.5 |
0.7 |
1.4 |
23.5 |
904 |
1000 |
30x2.5 |
0.7 |
1.5 |
25.1 |
1113 |
500 |

|