PiMF
|
Criteria |
Standard Values |
Unit |
||||
Conductor cross section |
Nominal |
0.5 |
0.75 |
1 |
1.5 |
2.5 |
mm² |
Conductor DC Resistance @ 20oC |
max. |
40.4 |
26 |
19.2 |
12.8 |
7.86 |
Ohm/kM |
Insulation resistance |
min. |
1000 |
MOhm x km |
||||
Mutual capacitance |
max. |
150 |
nF/km |
||||
L/R (ratio) |
max. |
25 |
25 |
25 |
40 |
60 |
microH/Ohm |
Test voltage : |
for 5 minutes |
1.5 kV A.C |
K.V |
||||
core to core |
|||||||
core to screen |
|||||||
Operating voltage U(rms) |
|
300 |
V |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 0.5 mm2 (7x0.30 mm) |
|||||||
1x2x0.5 |
0.4 |
0.2 |
7.0 |
1.1 |
10.1 |
158 |
1000 |
2x2x0.5 |
0.4 |
0.3 |
10.7 |
1.2 |
14.4 |
272 |
1000 |
3x2x0.5 |
0.4 |
0.3 |
11.4 |
1.3 |
15.3 |
333 |
1000 |
4x2x0.5 |
0.4 |
0.3 |
12.4 |
1.3 |
16.4 |
380 |
1000 |
5x2x0.5 |
0.4 |
0.3 |
13.6 |
1.3 |
17.6 |
442 |
1000 |
6x2x0.5 |
0.4 |
0.3 |
14.9 |
1.4 |
19.0 |
499 |
1000 |
7x2x0.5 |
0.4 |
0.3 |
14.9 |
1.4 |
19.0 |
532 |
1000 |
10x2x0.5 |
0.4 |
0.3 |
19.1 |
1.5 |
23.4 |
725 |
1000 |
12x2x0.5 |
0.4 |
0.3 |
19.7 |
1.6 |
24.3 |
810 |
1000 |
16x2x0.5 |
0.4 |
0.3 |
22.0 |
1.6 |
26.6 |
991 |
500 |
20x2x0.5 |
0.4 |
0.3 |
24.7 |
1.7 |
29.4 |
1169 |
500 |
24x2x0.5 |
0.4 |
0.3 |
27.5 |
1.8 |
32.4 |
1374 |
500 |
30x2x0.5 |
0.4 |
0.3 |
29.2 |
1.9 |
34.3 |
1632 |
500 |
Conductor : 0.75 mm2 (7x0.37 mm) |
|||||||
1x2x0.75 |
0.5 |
0.2 |
7.8 |
1.1 |
10.9 |
174 |
1000 |
2x2x0.75 |
0.5 |
0.3 |
12.1 |
1.3 |
16.1 |
326 |
1000 |
3x2x0.75 |
0.5 |
0.3 |
12.9 |
1.3 |
16.9 |
377 |
1000 |
4x2x0.75 |
0.5 |
0.3 |
14.2 |
1.4 |
18.4 |
457 |
1000 |
5x2x0.75 |
0.5 |
0.3 |
15.6 |
1.4 |
19.7 |
529 |
1000 |
6x2x0.75 |
0.5 |
0.3 |
17.1 |
1.5 |
21.4 |
597 |
1000 |
7x2x0.75 |
0.5 |
0.3 |
17.1 |
1.5 |
21.4 |
638 |
1000 |
10x2x0.75 |
0.5 |
0.3 |
22.0 |
1.6 |
26.5 |
874 |
500 |
12x2x0.75 |
0.5 |
0.3 |
22.8 |
1.7 |
27.5 |
978 |
500 |
16x2x0.75 |
0.5 |
0.3 |
25.4 |
1.8 |
30.4 |
1211 |
500 |
20x2x0.75 |
0.5 |
0.3 |
28.5 |
1.9 |
33.7 |
1433 |
500 |
24x2x0.75 |
0.5 |
0.4 |
32.2 |
2.0 |
38.0 |
1812 |
500 |
30x2x0.75 |
0.5 |
0.4 |
34.3 |
2.1 |
40.3 |
2107 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 1.0 mm2 (7x0.43 mm) |
|||||||
1x2x1 |
0.5 |
0.2 |
8.2 |
1.1 |
11.3 |
173 |
1000 |
2x2x1 |
0.5 |
0.3 |
12.8 |
1.3 |
16.7 |
329 |
1000 |
3x2x1 |
0.5 |
0.3 |
13.6 |
1.3 |
17.6 |
396 |
1000 |
4x2x1 |
0.5 |
0.3 |
15.0 |
1.4 |
19.1 |
457 |
1000 |
5x2x1 |
0.5 |
0.3 |
16.4 |
1.4 |
20.6 |
535 |
1000 |
6x2x1 |
0.5 |
0.3 |
18.0 |
1.5 |
22.4 |
605 |
1000 |
7x2x1 |
0.5 |
0.3 |
18.0 |
1.5 |
22.4 |
646 |
1000 |
10x2x1 |
0.5 |
0.3 |
23.3 |
1.7 |
28.0 |
901 |
500 |
12x2x1 |
0.5 |
0.3 |
24.1 |
1.7 |
28.9 |
995 |
500 |
16x2x1 |
0.5 |
0.3 |
26.9 |
1.8 |
31.9 |
1233 |
500 |
20x2x1 |
0.5 |
0.3 |
30.2 |
1.9 |
35.4 |
1481 |
500 |
24x2x1 |
0.5 |
0.4 |
34.2 |
2.1 |
40.2 |
1865 |
500 |
30x2x1 |
0.5 |
0.4 |
36.3 |
2.1 |
42.3 |
2187 |
500 |
Conductor : 1.5 mm2 (7x0.53 mm) |
|||||||
1x2x1.5 |
0.6 |
0.2 |
9.2 |
1.2 |
12.5 |
209 |
1000 |
2x2x1.5 |
0.6 |
0.3 |
14.6 |
1.4 |
18.7 |
404 |
1000 |
3x2x1.5 |
0.6 |
0.3 |
15.5 |
1.4 |
19.7 |
485 |
1000 |
4x2x1.5 |
0.6 |
0.3 |
17.1 |
1.5 |
21.5 |
569 |
1000 |
5x2x1.5 |
0.6 |
0.3 |
18.9 |
1.5 |
23.2 |
665 |
1000 |
6x2x1.5 |
0.6 |
0.3 |
20.7 |
1.6 |
25.2 |
755 |
500 |
7x2x1.5 |
0.6 |
0.3 |
20.7 |
1.6 |
25.2 |
810 |
500 |
10x2x1.5 |
0.6 |
0.3 |
26.8 |
1.8 |
31.8 |
1126 |
500 |
12x2x1.5 |
0.6 |
0.3 |
27.8 |
1.8 |
32.8 |
1250 |
500 |
16x2x1.5 |
0.6 |
0.4 |
31.5 |
2.0 |
37.3 |
1700 |
500 |
20x2x1.5 |
0.6 |
0.4 |
35.4 |
2.1 |
41.4 |
2004 |
500 |
24x2x1.5 |
0.6 |
0.4 |
39.5 |
2.3 |
45.9 |
2378 |
500 |
30x2x1.5 |
0.6 |
0.4 |
42.0 |
2.4 |
48.6 |
2818 |
500 |
Nominal cross section area of conductor |
Insulation thickness |
Armour Wire Diameter |
Diameter Under Armour |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
Conductor : 2.5 mm2 (7x0.67 mm) |
|||||||
1x2x2.5 |
0.6 |
0.2 |
10.0 |
1.2 |
13.3 |
250 |
1000 |
2x2x2.5 |
0.6 |
0.3 |
16.0 |
1.4 |
20.2 |
484 |
1000 |
3x2x2.5 |
0.6 |
0.3 |
17.2 |
1.5 |
21.5 |
584 |
1000 |
4x2x2.5 |
0.6 |
0.3 |
18.9 |
1.5 |
23.3 |
705 |
1000 |
5x2x2.5 |
0.6 |
0.3 |
20.9 |
1.6 |
25.4 |
818 |
500 |
6x2x2.5 |
0.6 |
0.3 |
22.9 |
1.7 |
27.7 |
956 |
500 |
7x2x2.5 |
0.6 |
0.3 |
22.9 |
1.7 |
27.7 |
1034 |
500 |
10x2x2.5 |
0.6 |
0.3 |
29.8 |
1.9 |
35.0 |
1435 |
500 |
12x2x2.5 |
0.6 |
0.4 |
31.3 |
2.0 |
37.1 |
1751 |
500 |
16x2x2.5 |
0.6 |
0.4 |
35.0 |
2.1 |
41.0 |
2143 |
500 |
20x2x2.5 |
0.6 |
0.4 |
39.4 |
2.3 |
45.8 |
2611 |
500 |
24x2x2.5 |
0.6 |
0.4 |
44.4 |
2.5 |
51.2 |
3142 |
250 |
30x2x2.5 |
0.6 |
0.4 |
47.2 |
2.6 |
54.2 |
3692 |
250 |

|