NA2XSEYBY
3.6/6 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Diameter Under Armour |
Armour Tape Thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x25rm/16 |
5.8 |
2.5 |
33.4 |
0.5 |
2.2 |
39.8 |
2345 |
500 |
3x35rm/16 |
7.0 |
2.5 |
37.4 |
0.5 |
2.3 |
44.0 |
2782 |
500 |
3x50rm/16 |
8.2 |
2.5 |
40.0 |
0.5 |
2.4 |
46.8 |
3151 |
500 |
3x70rm/16 |
9.9 |
2.5 |
43.9 |
0.5 |
2.5 |
50.9 |
3694 |
500 |
3x95rm/16 |
11.5 |
2.5 |
47.5 |
0.5 |
2.7 |
54.9 |
4303 |
500 |
3x120rm/16 |
13.0 |
2.5 |
50.7 |
0.5 |
2.8 |
58.3 |
4848 |
500 |
3x150rm/25 |
14.5 |
2.5 |
54.2 |
0.5 |
2.9 |
62.0 |
5476 |
500 |
3x185rm/25 |
16.1 |
2.5 |
58.7 |
0.5 |
3.1 |
66.9 |
6344 |
500 |
3x240rm/25 |
18.5 |
2.6 |
64.4 |
0.5 |
3.2 |
72.8 |
7484 |
250 |
3x300rm/25 |
20.6 |
2.8 |
70.9 |
0.5 |
3.5 |
79.9 |
8942 |
250 |
6/10 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Diameter Under Armour |
Armour Tape Thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x25rm/16 |
5.8 |
3.4 |
38.7 |
0.5 |
2.4 |
45.5 |
2887 |
500 |
3x35rm/16 |
7.0 |
3.4 |
41.3 |
0.5 |
2.5 |
48.3 |
3230 |
500 |
3x50rm/16 |
8.2 |
3.4 |
44.1 |
0.5 |
2.6 |
51.3 |
3647 |
500 |
3x70rm/16 |
9.9 |
3.4 |
47.9 |
0.5 |
2.7 |
55.3 |
4223 |
500 |
3x95rm/16 |
11.5 |
3.4 |
51.4 |
0.5 |
2.8 |
59.0 |
4804 |
500 |
3x120rm/16 |
13.0 |
3.4 |
54.8 |
0.5 |
2.9 |
62.6 |
5404 |
500 |
3x150rm/25 |
14.5 |
3.4 |
58.2 |
0.5 |
3.0 |
66.2 |
6061 |
250 |
3x185rm/25 |
16.1 |
3.4 |
62.5 |
0.5 |
3.2 |
70.9 |
6932 |
250 |
3x240rm/25 |
18.5 |
3.4 |
67.9 |
0.5 |
3.3 |
76.5 |
8068 |
250 |
3x300rm/25 |
20.6 |
3.4 |
73.5 |
0.5 |
3.5 |
82.5 |
9385 |
250 |
8.7/15 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Diameter Under Armour |
Armour Tape Thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x25rm/16 |
5.8 |
4.5 |
43.7 |
0.5 |
2.6 |
50.9 |
3469 |
500 |
3x35rm/16 |
7.0 |
4.5 |
46.2 |
0.5 |
2.6 |
53.4 |
3814 |
500 |
3x50rm/16 |
8.2 |
4.5 |
49.0 |
0.5 |
2.7 |
56.4 |
4259 |
500 |
3x70rm/16 |
9.9 |
4.5 |
52.9 |
0.5 |
2.9 |
60.7 |
4900 |
500 |
3x95rm/16 |
11.5 |
4.5 |
56.3 |
0.5 |
3.0 |
64.3 |
5532 |
250 |
3x120rm/16 |
13.0 |
4.5 |
59.7 |
0.5 |
3.1 |
67.9 |
6155 |
250 |
3x150rm/25 |
14.5 |
4.5 |
63.2 |
0.5 |
3.2 |
71.6 |
6847 |
250 |
3x185rm/25 |
16.1 |
4.5 |
67.5 |
0.5 |
3.3 |
76.1 |
7731 |
250 |
3x240rm/25 |
18.5 |
4.5 |
72.8 |
0.5 |
3.5 |
81.8 |
8946 |
250 |
3x300rm/25 |
20.6 |
4.5 |
78.4 |
0.8 |
3.7 |
89.0 |
11246 |
250 |
12/20 kV (IEC 60502 - 2)
Nominal cross section area of conductor |
Conductor Diamater |
Insulation thickness |
Diameter Under Armour |
Armour Tape Thickness |
Sheath thickness |
Overall Diameter |
Weight |
Standard Packing Length |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
Kg/Km |
meter |
3x35rm/16 |
7.0 |
5.5 |
50.7 |
0.5 |
2.8 |
58.3 |
4426 |
500 |
3x50rm/16 |
8.2 |
5.5 |
53.5 |
0.5 |
2.9 |
61.3 |
4898 |
500 |
3x70rm/16 |
9.9 |
5.5 |
57.4 |
0.5 |
3.0 |
65.4 |
5551 |
500 |
3x95rm/16 |
11.5 |
5.5 |
60.8 |
0.5 |
3.2 |
69.2 |
6230 |
500 |
3x120rm/16 |
13.0 |
5.5 |
64.2 |
0.5 |
3.3 |
72.8 |
6900 |
500 |
3x150rm/25 |
14.5 |
5.5 |
67.5 |
0.5 |
3.4 |
76.3 |
7580 |
250 |
3x185rm/25 |
16.1 |
5.5 |
72.0 |
0.5 |
3.5 |
81.0 |
8550 |
250 |
3x240rm/25 |
18.5 |
5.5 |
77.3 |
0.8 |
3.8 |
88.1 |
10795 |
500 |

|